Text

gpss 5

19SS

~ ~

Docket No.:

50-400 Mr. E.

E. Utley Executive Vice President Power Supply and Engineering and Construction Carolina Power 5 Light Company Post Office Box 1551 Raliegh, North Carolina 27602

Dear Mr. Utley:

SUBJECT:

SELECTION OF EQUIPMENT TO BE AUDITED BY THE PUMP AND VALVE OPERABILITY REVIEW TEAM (PVORT)

AND SEISMIC QUALIFICATION REVIEW TEAM (SQRT) - SHEARON HARRIS, UNIT 1 Enclosure (1) and Enclosure (2) de 1 ineate the equipment selected for audit by the Pump and Valve Operability Review Team and the Seismic Qualification Review Team, respectively.

The above cited audits are requested to start at the Shearon Harris site at 8:30 a.m.

December 3, 1985.

Sincerely, NJgtBBf Vga@f gy.

<~Ca

~- Nghtaa George W. Knighton, Chief Licensing Branch No.

3 Division of Licensing

Enclosures:

As stated cc:

See next page Distribution:

Docket Fi-le50-400 NRC PDR Local PDR PRC System NSIC LB¹3 Reading JLee BBuc ley DL:

DL BBuckley/es G

10/ 5(/85

$ P/

/85 OELD, Attorney ACRS (16)

JPartlow BGrimes EJordan PDR gag~ 851i05 85'gpp~

A sooo~oo pna

~ ~

~ y t~

~

~

~

'I S

C 1

~q II I

II 1l1)h h

g I'

0 I

1 r

iW h

I'

Mr. E. E. Utley Carolina Power 5 Light Company Shearon Harris Cco George F. Trowbridge, Esq.

Shaw, Pittman, Potts 8 Trowbridge 1800 M Street',

NW Washington, DC 20036 Richard E. Jones, Esq.

Associate General Counsel Carolina Power 5 Light Company 411 Fayetteville Street Mall Raleigh, North Carolina 27602 M. David Gordon, Esq.

Associate Attorney General State of North Carolina Post Office Box 629 Raleigh, North Carolina 27602 Thomas S. Erwin, Esq.

115 W. Morgan Street Raleigh, North Carolina 27602 Resident Inspector/Harris NPS c/o U.S. Nuclear Regulatory Commission Route I, Box 315B New Hill, North Carolina 27562 Charles D. Barham, Jr.,

Esq.

Vice President 5 Senior Counsel Carolina Power 5 Light Company Post Office Box 1551 Raleigh, North Carolina 27602 Mr. John Runkle, Executive Coordinator Conservation Council of North Carolina 307 Granville Road Chapel Hill, North Carolina 27514 Mr. 'Wells Eddleman 806 Parker Street Durham, North Carolina 27701 Mr. George Jackson, Secretary Environmental Law Project School of Law, 064-A Univeristy of North Carolina Chapel Hill, North Carolina 27514 Mr. Travis Payne, Esq.

723 W. Johnson Street Post Office Box 12643 Raleigh, North Carolina 27605 Mr. Daniel F.

Read CHANGE Post Office Box 2151

Raleigh, North Car olina 27602 Bradley W. Jones, Esq.

U.S. Nuclear Regulatory Comm.

Region II 101 Marietta Street Atlanta, Georgia 30303 Richard D. Wilson, M. D.

725 Hunter Street Apex, North Carolina 27502 Regional Administrator, Region II U.S. Nuclear Regulatory Comnission 101 Marietta Street

. Suite 2900 Atlanta, Georgia 30303 Mr. Robert P. Gruber Executive Director Public Staff - NCUC Post Office Box 991 Raleigh, North Carolina 27602

Carolina Power

& Light Company Shearon Harris CC:

Dr. Linda Little Governor's Waste Management Board 513 Albemarle Building 325 North Salisbury Street Raleigh, North Carolina 27611

~ ~

BFB Pum

+

Shear In I ar r '<<PV RT

<<di En'Cl.OS'ure I u +be D&s I"

')t I'II'I anu.acturer

~O'I: O'.I'l APBA-1A-SA Bol"il acid transfer Chempump CVCS APRH-1B-SB Residual heat removal Ingersoll-Rand APCC-1C-SAB Component cooling

.Paci fic CCS Va ves or I.

ar 's PVQR T

ul'll

- I" a

u actur r RH-FGOOSN SCC-B20SB 2WL-D600$4-1 SCC-V165SA 2CS-L612SA Flo-Control Butter fly Globe Gate Check Continental fisher Copes-Vulcan Velan Westinghouse 18 V

R '

Ta Number P14-SA Descri tiorl Emergency screen wash anu+aeturer

'I Crane-Deming

~Sit 0 Ill P1A-SA Emergency screen water Hayward-Tyler SW P4 ( 14-SA )

Essential service Gould chilled water CH 1ASA C.S.

Co ntai nme nt sp I"ay Ingersoll-Rand CT

~ >

~ ~

BOP Va ve~v r Shel!Lr 0 a 'e r Dahl AB21/P40 BOP-8 BOP-9 Main Steam Valve Control Room Cabinet 2-NS-Pi 9SB-1 09183 RNC-1 1 0G74 Paul Munro Ganeral Atomics AB32/Valve Ntd RNC-1 BOP-10 Screen Wash Pump and

~

1-.ASA-SCWP Motur Motor 08070 Crane Deming/

IE31/261 Reliance BOP-12 30 in; Butter fly Valve 3SW-B106SB-1 Jamesbur y Crop TA11/236 OG261

II

~

V o ~

~ ~

TABI-E 4.

ALTERNATL= BOP EQUXPNLNT LXST FOR Sl-IEARON I-IARRXS UllI e I E

Ii Ill I'I Reference N U Illl3 e Vendo Locat ion:

Bld /6'lc'iv BOP-lA 125 V DC Bat.te ry 1A-SA-RAB 08542 CGD Battery AB43/266 BOP-2A Hydra Notor Valve Operator 3CX-W17SA-1 09519 XTT General AB52/305 BOP-3A Diesel Generator Cont r ol Panel CP-1B 1 0692 Delaval DG31/261 BOP-4A Xnstrument Rack and Panels PNL-1WV-3 546-1 13349 TEC

/276