Submits Response to IE Bulletin 79-03A.No Welded SA-312 or A-312,Type 300 Series Stainless Steel Has Been Used or Is Planned for Use in safety-related Piping Sys
ML18017B216
Person / Time
Site: Harris  Duke Energy icon.png
Issue date: 08/05/1980
From: Mcduffie M
CAROLINA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
IEB-79-03A, IEB-79-3A, NUDOCS 8009020203
Download: ML18017B216 (1)


Text

b)

Carolina power 8 Light Co~arty August 5, 1980

.'j I<<I~< [I A

Mr J

P O'Reilly Region II U. S. Nuclear Regulatory Commission 101 Marietta Street, N.W.

Atlanta, Georgia 30303 SHEARON NUCLEAR POWER PLANT N S. 1, 2, 3 AND 4 DOCKET NOS. 50-400 50-401, 50-402, AND 50-403 ULLETIN 79-03A

Dear Mr. O'Reilly:

As requested in IE Bulletin 79-03A, Carolina Power

& Light Company (CP&L) has reexamined the design and records for the Shearon Harris Nuclear Power Plant (SHNPP) and determined that no welded SA-312 or A-312, Type 300 Series Stainless Steel has been used or is planned for use in safety-related piping systems at the SHNPP.

In addition, the architect-engineer and the steel fabricating company have both been reminded of the provisions of the applicable piping specifi-cation which prohibits the use of this type of stainless steel in safety-related systems.

If you have any questions on this subject, please contact our staff.

CP&L plans no further response to this bulletin.

Yours very truly, M cz M ~if..pj M. A. McDuffie Senior Vice President Engineering

& Construction MAM/dk cc:

Director, Division of Reactor Construction Inspection United States Nuclear Regulatory Commission Washington, DC 20555 8,009980 <

V I

a1! FayetteVitte Street

~ P. O. SOX 155t

~ Raleigh, N. C. 27602

~ii.yM~~KR~~~~~~iFiFLh~~~L.~~

'.r~ VJCfAl;HO!""