ML18016A926

From kanterella
Jump to navigation Jump to search

Forwards Request for Addl Info Re 981223 Request for License Amend to Revise Shearon Harris NPP TS 5.6 to Increase Sf Storage Capacity by Adding Rack Modules to Pools C & D. Requests Response by 990630
ML18016A926
Person / Time
Site: Harris 
Issue date: 04/29/1999
From: Richard Laufer
NRC (Affiliation Not Assigned)
To: Scarola J
CAROLINA POWER & LIGHT CO.
References
TAC-MA4432, NUDOCS 9905040318
Download: ML18016A926 (7)


Text

Mr. James Scarola, Vice ident Shearon Harris Nuclear Power Plant

. Carolina Power 8 Light Company Post Office Box 165, Mail Code: Zone 1

New Hill, North Carolina 27562-0165 April 29, 19+

SUBJECT:

REQUEST FOR ADDITIONALINFORMATIONREGARDING AMENDMENT REQUEST TO INCREASE FUEL STORAGE CAPACITY-SHEARON HARRIS NUCLEAR POWER PLANT (TAC NO. MA4432)

Dear Mr. Scaroia 1

By letter dated December 23,'998,,you requested a license amendnient to revise Shearon Harris Nuclear Power Plant Technical, Specification (TS) 5.6, "Fuel Storage," to increase the spent fuel storage capacity by adding rack modules to pools 'C'nd 'D.'

I During the course of its review, th'e NRC.staff has determined that'additional information is necessary to complete its review. The enclosed request for additional information was discussed with your Licensing staff on April 29, 1999. A mutually agreeable target date of June 30, 1999, for your response was established.

Ifcircumstances result in the need to revise the target date, please call me at the earliest opportunity.

Sincerely, Original signed by:

Docket No. 50-400

Enclosure:

As stated Richard J. Laufer, Project Manager, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation cc w/encl: See next page Distribution LDocket~File~

'PD II Rdg LKopp EDunnington OGC FILENAME-G:iHARRIS>RAI4432.WPD PUBLIC JZwolinski/S Black RLaufer ACRS HBerkow BBonser, Rll OFFICE NAME DATE "l/~t/99 6Z1 /99'/ >7/99 PM:PDII/S2 LA:PDII/S2 C:

RXB RLaufer P EDunni g on JW iel SC:PDII/S2 SPeterV

'I/A/99

/

/99 COPY

/No Yes o

es No Yes/

o Yes/No OFFICIAL CORD COPY

~;) noh~

99050403i8 990429-

l i

PDR ADQCK 05000400 P

PDR

I f

1 i

~.,

's f!jIIf)g i,j i

',. )z

', p j

~ l

~

~a R50(

P

+w*w+

UNITED STATES NUCLEAR REGULATORY COIVIMISSION WASHINGTON> D.C. 20555-0001 Apri1 29, 1999 Mr. James Scarola, Vice President Shearon Harris Nuclear Power Plant Carolina Power 8 Light Company PostOffice Box165, Mail Code: Zone1 New Hill, North Carolina 27562-0165

SUBJECT:

REQUEST FOR ADDITIONALINFORMATIONREGARDING AMENDMENT REQUEST TO INCREASE FUEL STORAGE CAPACITY-SHEARON HARRIS NUCLEAR POWER PLANT (TAC NO. MA4432)

Dear Mr. Scarola:

By letter dated December 23, 1998, you requested a license amendment to revise Shearon Harris Nuclear Power Plant Technical Specification (TS) 5.6, "Fuel Storage," to increase the spent fuel storage capacity by adding rack modules to pools 'C'nd

'D.'uring the course of its review, the NRC staff has determined that additional information is necessary to complete its review. The enclosed request for additional information was discussed with your Licensing staff on April29, 1999. A mutually agreeable target date of June 30, 1999, for your response was established.

Ifcircumstances result in the need to revise the target date, please call me at the earliest opportunity.

Sincerely, Richard J. Laufer, Project Manager, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-400

Enclosure:

As stated cc w/encl: See next page

REQUEST FOR ADDITIONALINFORMATION Although the burnup criteria for storage in Pools C or D willbe implemented by administrative procedures to ensure verified burnup prior to fuel transfer into these pools, an administrative failure should be assumed and evaluation of a fuel assembly misloading event (i.e., a fresh pressurized-water reactor (PWR) assembly inadvertently placed in a location restricted to a burned assembly as per Technical Specifications (TS)

Figure 5.6.1) should be analyzed.

2; How willthe burnup requirements needed to meet TS Figure 5.6.1 be ascertained for fuel assemblies shipped from other PWR plants (Robinson)?

3.

The fuel enrichment tolerance is specified in Section 4.5.2.5 as+0.0/-0.05.

Why isn't a positive tolerance of +0.05 assumed (i.e., 5.0+0.05 weight percent U-235)?

4.

Justify that the allowance that was assumed for possible differences between the fuel vendor and the Holtec calculations is sufficient to also encompass burnup calculational uncertainties.

5.

The summary of criticality safety calculations shown in Tables 4.2.1 and 4.2.2 indicates that the total uncertainty is a statistical combination of the manufacturing tolerances but do not indicate methodology biases and uncertainties.

Were these included?

Enclosure

Mr. James Scarola Carolina Power 8 Light Company Shearon Harris Nuclear Power Plant Unit 1 CC:

Mr. William D. Johnson Vice President and Corporate Secretary Carolina Power 8 Light Company Post Office Box 1551 Raleigh, North Carolina 27602 Resident Inspector/Harris NPS c/o U.S. Nuclear Regulatory Commission 5421 Shearon Harris Ro'ad New Hill, North Carolina 27562-9998 Ms. Karen E. Long Assistant Attorney General State of North Carolina Post Office Box 629 Raleigh, North Carolina 27602 Public Service Commission State of South Carolina Post Office Drawer Columbia, South Carolina 29211 Director of Site Operations Carolina Power 8 Light Company Shearon Harris Nuclear Power Plant Post Office Box 165, MC: Zone 1

New Hill, North Carolina 27562-0165 Mr. Robert P. Gruber Executive Director Public Staff NCUC Post Office Box 29520 Raleigh, North Carolina 27626 Chairman of the North Carolina Utilities Commission Post Office Box 29510 Raleigh, North Carolina 27626-0510

~ c Mr. Mel Fry, Director Division of Radiation'Protection N.C. Department of Environment and Natural Resources 3825 Barrett Dr.

Raleigh, North Carolina 27609-7721 Mr. Terry C. Morton Manager Performance Evaluation and Regulatory Affairs CPB 9 Carolina Power & Light Company Post Office Box 1551 Raleigh, North Carolina 27602-1551 Mr. Bo Clark Plant General Manager - Harris Plant Carolina Power 8 Light Company Shearon Harris Nuclear Power Plant P.O. Box 165 New Hill, North Carolina 27562-0165 Mr. John H. O'eill, Jr.

Shaw, Pittman, Potts 8 Trowbridge 2300 N Street, NW.

Washington, DC 20037-1128 Mr. Vernon Malone, Chairman Board of County Commissioners of Wake County P. O. Box 550 Raleigh, North Carolina 27602 Mr. Richard H. Givens, Chairman Board of County Commissioners of Chatham County P. O. Box 87 Pittsboro, North Carolina 27312 Ms. Donna B. Alexander, Manager Regulatory Affairs Carolina Power 8 Light Company Shearon Harris Nuclear Power Plant P.O. Box 165, Mail Zone 1

New Hill, NC 27562-0165 Mr. Johnny H. Eads, Supervisor Licensing/Regulatory Programs Carolina Power 8 Light Company Shearon Harris Nuclear Power Plant P. O. Box165, MailZone1 New Hill, NC 27562-0165 Ms. Diane Curran Harmon, Curran, Spielberg, and Eisenberg, L.L.P.

1726 M Street NW., Suite 600 Washington, DC 20036

.J