TABLE 3. 3-4 Continued TABLE NOTATIONS "Time constants utilized in the lead-lag controller for Steam Line Pressure-Low are r> ) 50 seconds and TZ 5 seconds.
CHANNEL CALIBRATION shall ensure that these time constants are adjusted to these values.
""The time constant utilized in the rate-la controller for Steam Line Pressure-Negative Rate-High is 50 seconds.
CHANNEL CALIBRATION shall ensure that this
>me constant is adjusted to this value.
OThe indicated values are the effective, cumulative, rate-compensated pressure drops as seen by the comparator.
(
9903100046 990226 I7 PDR ADQCK 05000400 P
PDRQ SHEARON HARRIS " UNIT 1 3/4 3-36
~I TABLE 3.3-4 Continued TABLE NOTATIONS
~
~
Tirade constants utilized in the lead-lag controller for Steam Line Pressure-Low are vy
> 50 seconds and 7,
5 seconds.
I CHANNEL CALIBRATION shall ensure that these time constants are adjusted to these values'he time constant utilized in the rate-lag controller for Steam Line Pressure-Negative Rate--High is
> 50 seconds.
CHANNEL CALIBRATION shall ensure that this time constant is adjusted to this value.
The indicated values are the effective, cumulative, rate-compensated pressure drops as seen by the comparator.
SHEARON HARRIS UNIT 3/4 3-36 Amendment No.