ENCLOSURE 5 SHEARON HARRIS NUCLEARPOWER PLANT NRC DOCKET NO. 50-400/LICENSE NO. NPF-63 REQUEST FOR LICENSE AMENDMENT TRIAXIALPEAK ACCELEROGRAPH LOCATION TECHNICALSPECIFICATION PAGES 9bOb0700i8 9b053i PDR ADQCK 05000400I P
~4 TABLE 3.3~7 SEISMIC MONITORING INSTRUMEHTATION INSTRUMENTS ANO SEHSOR LOCATIONS
- 1. Triaxfal Time-Hfstory Accelerographs a.
Containment Mat (EI 221 ft)
- b. Containment (El 286 ft)
- c. Ofesel Fuel Of 1 Storage Tank Building (El 242 ft)
- 2. Triaxfal Peak Accelerograph Recorders
~s a.
Reactor Coolant Pipe (Loop g) b.
Steam Generator IA Pedestal (EI'.238.ft) )
c'. Reactor Auxiliary Building (El 236 ft)
)"-
- 3. Trfaxfa.l,. Seismic Swftches
- a. Starter Unit for Time Hfs ory Accalerograph Systen-Containment Mat (El 221 ft)
- b. Trfaxfal Sefsmfc SwitchContafnment Mat {El 221 ft)
- 4. Trfaxfal Response-Spectrum Recorders a.
Steam Generator 18 Pedestal
{El 238 ft)
- b. Reactor Auxflfary Building (El 216 ft)
MEASVREMEHT RANGE 0.01"1.0 g 0.01-1.0 g
0.01-1.0 g
LO g
-2g
~ 10 g 0.005 " 0.05 0.025 - 0.25 2 g MINIMUM INSTRUMENTS OPERABLE
- c. Qfesel Fuel Oil Storage Tank Building o 2 g (E1 242 ft)
- d. Containment Building (El 221 ft)
~2g
'Hath mafn control room indication.
"'%fth main control room recording.
SHEARON HARRIS - UNIT 1 3'
58
I l
TABLE 4. 3-4 SEISMIC MONITORING INSTRUMENTATION SURVEILLANC REOUIREMENTS INSTRUMENTS ANO SENSOR LOCATIONS
- 1. Trfaxfal Time-History Accelerographs a.
Containment Mat (El 221 ft)
- b. Containment (El 286 ft)
- c. Ofesel Fuel Ofl Storage Tank Building (El 242 ft)
ANALOG CHANNEL CHANNEL CHANNEL OPERATIONAL CHECK CALIBRATION TEE SAR%'R SARRR SA~R
- 2. Triaxial Peak Accelerograph Recorde a.
Reactor Coolant Pipe (Loop H.A.
- c. Reactor Auxilfary Building (El Z36 ft)
- 3. Trfaxial Seismic Swftches
- a. Starter Unit for Time Hfstory Accelerograph System Containment Mat (El 221 ft)~
- b. Triaxfal Seismic S~f tch-Containment Mat (El ZZl ft)~
- 4. Trfaxial Response-Spectrum Recorders a.
Containment Bufldfng (Active)
(El 221 ft)~"
N.A.
b.
Steam Generator IA Pedestal (El 238 ft)
N.A.
N.A.
f N.A.
N.A.
SASSY Span%
b.
Steam Generator (Passive)
XB Pedestal
- c. Reactor Auxiliary Building (Passive)
(El 2N ft)
- d. Ofesel Fuel Of 1 Storage Tank Building (Passive)
(El 24Z ft)
N.A.
H.A.
H.A.
N.A.
N.A.
N.A.
"Except seismic starter unft.
~"0th main control room alarms.
The bfstable trip setpofnt need not be determined during the performance of a channel operatfonal test.
SHEARON HARRIS UNIT 1 3/4 3-59
TABLE 3.3-7 0
SEISMIC MONITORING INSTRUMENTATION INSTRUMENTS AND SENSOR LOCATIONS
- 1. Triaxial Time-History Accelerographs
- a. Containment Mat (El 221 ft)
- b. Containment (El 286 ft)
- c. Diesel Fuel Oil Storage Tank Building (El 242 ft)
- 2. Triaxial Peak Accelerograph Recorders a.
Reactor Coolant Pipe (Loop B) b.
Steam Generator 1A Pedestal (El 238 ft)
- c. Reactor Auxiliary Building (El 236 ft)
- 3. Triaxi a 1 Sei smi c Swi tches
- a. Starter Unit for Time History Accelerograph System--Containment Mat (El 221 ft)
MEASUREMENT RANGE 0.01-1.0 g
0.01-1.0 g
0.01-1.0 g
+10 g
+2g
+10g 0.005
- 0.05 MINIMUM INSTRUMENTS OPERABLE 1**
1**
1**
- b. Triaxial Seismic Switch--Containment 0.025
- 0.25 Mat (El 221 ft) 1*
- 4. Tri axial Response-Spectrum Recorders a.
Steam Generator 1B Pedestal (El 238 ft)
- b. Reactor Auxiliary Building (El 216 ft)
+2g
+2g
- c. Diesel Fuel Oil Storage Tank Building
+ 2 g (El 242 ft)
- d. Containment Building (El 221 ft)
'With main control room indication.
- "With main control room recording.
+2g 1*
SHEARON HARRIS - UNIT 1 3/4 3-58 Amendment No.
~
) g TABLE 4 3-4
'EISMIC MONITORING INSTRUMENTATION SURVEILLANCE RE UIREMENTS INSTRUMENTS AND SENSOR LOCATIONS ANALOG CHANNEL CHANNEL CHANNEL OPERATIONAL CHECK CALIBRATION TEST
- 1. Triaxial Time-History Accelerographs
- a. Containment Mat (El 221 ft)
M*
- b. Containment (El 286 ft)
M*
- c. Diesel Fuel Oil Storage Tank Building M*
(El 242 ft)
- 2. Triaxial Peak Accelerograph Recorders
- a. Reactor Coolant Pipe (Loop B) b.
Steam Generator lA Pedestal (El 238'ft)
N.A.
- c. Reactor Auxiliary Building (El 236 ft)
N.A.
- 3. Triaxial Seismic Switches
- a. Starter Unit for Time History Accelerograph System--Containment Mat (El 221 ft)
- b. Triaxial Seismic Switch--Containment M
Mat (El 221 ft)
- 4. Triaxial Response-Spectrum Recorders
- a. Containment Building (Active)
(El 221 ft)**
b.
Steam Generator (Passive) 1B Pedestal N.A.
- c. Reactor Auxiliary Building (Passive)
N.A.
(El 216 ft)
- d. Diesel Fuel Oil Storage Tank Building N.A.
(Passive)
(El 242 ft)
R SA R
SA R,
SA R
N.A.
R N.A.
R N.A.
"Except seismic starter unit.
"With main control room alarms.
The bistable trip setpoint need not be determined during the performance of a channel operational test.
SHEARON HARRIS - UNIT 1 3/4 3-59 Amendment No.