Text
FORD I
REGULATORY ZNFORMATION DISTRIBUTION SYSTEM (RIDS)
V
ACCESSION NBR:9403150185
DOC.DATE: 94/03/09
NOTARIZED:
NO
~
~
~
ACZL:50-400 Shearon Harris Nuclear
Power Plant, Unit 1, Carolina
AUTH.NAME
AUTHOR AFFILIATION
JAUDON,J.P.
Region
2 (Post
820201)
RECIP.NAME
RECIPIENT AFFILIATION
ROBINSON,W.R.
Carolina
Power
& Light Co.
DOCKET
05000400
S
05000400
I:
NOTES:Application for permit renewal filed.
SUBJECT: Forwards
insp rept 50-400/94-05
on 940115-0218
& forwards
notice of violation.Violations indicate recurring problems
w/conduct of filter backflushing evolutions
& ability to
identify problems w/plant computer
sys in reasonable
time.
DISTRIBUTION CODE:
IEOID
COPIES
RECEIVED:LTR L ENCL 3
SIZE:
+
TITLE: General
(50 Dkt)-Insp Rept/Notice of Violation Response
RECIPIENT
ID CODE/NAME
PD2-1
INTERNAL: ACRS
AEOD/DSP/ROAB
AEOD/TTC
NRR/DORS/OEAB
NRR/DRIL/RPEB
,NRR/PMAS/ILPB1
NUDOCS-ABSTRACT
OGC/HDSl
RES/HFB
EXTERNAL
EG&G/BRYCE F J II ~
COPIES
LTTR ENCL
1
1
2,
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
RECIPIENT
ID CODE/NAME
LEFN
AEOD/DEIB
AEOD/DSP/TPAB
DEDRO
NRR/DRCH/HHFB
NRR/DRSS/PEPB
NRR/PMAS/ILPB2
O~D'IR~
CREG~~
02
RGN2
FILE
01
NRC
COPIES
LTTR ENCL
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
~
NOTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK.
ROOM P!-37 (EXT. 504-2065) TO ELIMINATEYOUR NAME FROM DISTRIBUTION
LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES
REQUIRED:
LTTR
24
ENCL
24
Docket No.:
50-400
License No.:
Carolina
Power
and Light Company
ATTN: Mr.
W.
R. Robinson
Vice President
- Harris Plant
Shearon Harris Nuclear
Power Plant
P. 0.
Box 165
Mail Code:
Zone
1
New Hill, NC 27562-0165
Gentlemen:
SUBJECT:
NRC
INSPECTION
REPORT
NO. 50-400/94-05
This refers to the inspection
conducted
by J.
Tedrow of this office on
January
15 - February
18,
1994.
The inspection
included
a review of
activities authorized for your Harris facility.
At the conclusion of the
inspection,
the findings were discussed
with those
members of your staff
identified in the enclosed
inspection report.
Areas
examined during the inspection
are identified in the report.
Within
these
areas,
the inspection consisted
of selective
examinations of procedures
and representative
records,
interviews with personnel,
and observation of
activities in progress.
Based
on the results of this inspection,
certain of your activities appeared
to be in violation of NRC requirements,
as specified in the enclosed
Notice of
Violation (Notice).
The violations are of concern
because
they indicate
recurring problems with the conduct of filter backflushing evolutions
and your
ability to identify problems with the plant computer
system within a
reasonable
time.
In December
1991, the operators failed to implement
procedures
properly for the backflushing of the recycle evaporator feed'ilter
which resulted
in increased
airborne activity in the Waste Processing
Building.
A.non-cited violation
(NCV 400/91-27-02)
was issued for this
incident.
In August 1992, the operators failed to implement procedures
properly to backflush the seal
water return filter which resulted
in a
challenge to the system relief valve.
A Severity Level
IV violation was
issued for this incident
on September
17,
1992.
With regard to the recurring
problems with the plant computer system,
a similar failure occurred in January
1992 when operators failed to detect
an
ERFIS failure.
The
NRC expects
licensees
to learn from previous failures
and to take effective corrective
actions.
Therefore,
you are requested
to give particular attention to your
response
relative to the identification of the root cause of these
problems
and your corrective action to prevent recurrence.
>engr>-
9403150185
940309
ADOCK 05000400
8
Carolina
Power
and Light Company
2
In addition, the enclosed
Inspection
Report identifies activities that
violated
NRC requirements
that will not be subject to enforcement
action
because
the licensee's
efforts in identifying and/or correcting the violation
meet the criteria specified in Section VII.B. of the Enforcement Policy.
You are required to respond to this letter
and should follow the instructions
specified in the enclosed
Notice when preparing your response.
In your
response,
you should
document the specific actions
taken
and
any additional
actions you plan to prevent recurrence.
After reviewing your response
to this
Notice, including your proposed corrective actions
and the results of future
inspections,
the
NRC will determine
whether further
NRC enforcement
action is
necessary
to ensure
compliance with NRC regulatory requirements.
In accordance
with 10 CFR 2.790, of the NRC's "Rules of Practice,"
a copy of
this letter and its enclosures will be placed in the
NRC Public Document
Room.
The responses
directed
by this letter
and the enclosed
Notice are not subject
to the clearance
procedures
of the Office of Management
and Budget
as required
by the Paperwork Reduction Act of 1980,
Pub.
L. No. 96.511.
Should you have
any questions
concerning this letter,
please
contact
us.
Sincerely,
Original signed
by:
Johns
P. Jaudon/for
Jon
R. Johnson,
Acting Director
Division of Reactor Projects
Enclosures:
1.
2.
NRC Inspection
Report
cc w/encls:
Mr.
W. S. Orser
Executive Vice President
Nuclear Generation
Carolina
Power
& Light Company
P.
O.
Box 1551 - Mail Code:
CPB
12
Raleigh,
NC 27602
Mr. H.
W. Habermeyer,
Jr.
Vice President
Nuclear Services
Department
Carolina
Power
& Light Company
P. 0.
Box 1551 - Mail OHS7
Raleigh,
NC 27602
(cc w/encls cont'd - See
page 3)
Carolina
Power
and Light Company
(cc w/encls cont'd)
D.
C. McCarthy,
Manager
Regulatory Affairs
P. 0.
Box 165
New Hill, NC 27562-0165
H.
Ray Starling
Vice President
- Legal Department
Carolina
Power
and Light Company
P. 0.
Box 1551
Raleigh,
NC 27602
Dayne
H. Brown, Director
Division of Radiation Protection
N.
C. Department of Environment,
Health
5 Natural
Resources
P. 0.
Box 27687
Raleigh,
NC 27611-7687
Ms. Gayle
B. Nichols
Staff Counsel
SC Public Service
Commission
P. 0.
Box 11649
Columbia,
SC 29211
bcc w/encls:
H. Christensen,
RII
N. Le,
Document Control
Desk
NRC Resident
Inspector
U.S. Nuclear Regulatory
Commission
Route
1,
Box 315B
New Hill, NC 27562
RII:DRP
JStarefos:tj
03/3 /94
RII: RP
JTedrow
03/g /94
RI
HChristensen
03/P /94
RII:DRP/
DVerrelli
03/
/94
r c
03
/94