UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 CAROLINA POWER
& LIGHT COMPANY et al.
DOCKET NO. 50-400 SHEARON HARRIS NUCLEAR POWER PLANT 'UNIT 1
AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 33 License No.
NPF-63 The A.
B.
C.
D.
Nuclear Regulatory Commission (the Commission) has found that:
The application for amendment by Carolina Power
& Light Company (the licensee),
dated September 8,
- 1992, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; The facility will operate in conformity with the applicatioII, the provisions of the Act, and the rules and regulations of the Commission; There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications, as indicated in the attachment to this license amendment; and paragraph 2.C.(2) of Facility Operating License No.
NPF-63 is hereby amended to read as follows:
(2)
Technical S ecifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, and the Environmental Protection Plan contained in Appendix B, both of which are attached
- hereto, as revised through Amendment No.
33 are hereby incorporated into this license.
Carolina Power
& Light Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.
9211160354 921110 PDR ADOCK 05000400 P
~
~
3'.
This license amendment is effective as of the date of its issuance and shall be implemented within 60 days of issuance.
FOR THE NUCLEAR REGULATORY COMMISSION Elinor G. Adensam, Director Project Directorate II-I Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance:
November 10, 1992
ATTACHMENT TO LICENSE AMENDMENT NO.
33 FACILITY OPERATING LICENSE NO. NPF-63 DOCKET NO. 50-400 Replace the following page of the Appendix A Technical Specifications with the enclosed page.
The revised areas are indicated by marginal lines.
Remove Pa e
3/4 5-6 Insert Pa e
3/4 5-6
I
~
EMERGENCY CORE COOLING SYSTEMS SURVEILLANCE RE UIREMENTS Continued EBASCO Valve No.
CP&L Valve No.
2SI-V440SA-1 2SI-V439SB-1 2SI-V438SA-1 2SI-V437SA-1 2SI-V436SB-1 2SI-V435SA-1 2S I-V434SA-1 2SI-V433SB-1 2SI-V432SA-1 2SI-V431SA-1 2SI-V430SB-1 2SI-V429SA-1 1SI-5 1SI-6 1SI-7 1SI-69 1SI-70 1SI-71 1SI-101 1SI-102 1SI-103 1SI-124 1SI-125 1SI-126 h.
By performing a flow balance test, during shutdown, following com-pletion of modifications to the ECCS subsystems that alter the subsystem flow characteristics and verifying that:
1.
For Charging/safety injection pump
- lines, with a
single pump running:
a)
The sum of the injection line flow rates, excluding the highest flow rate, is greater than or equal to 348 gpm, and I
b)
The total pump flow rate is less than or equal to 685 gpm.
2.
For RHR pump lines, with a single pump running, the sum of the injection line flow rates is greater than or equal to 3663 gpm.
SHEARON HARRIS - UNIT 1 3/4 5-6 Amendment No.
33