Text
ACCELERATED DI TRIBUTION DEMON TION SYSTEM I
REGULATORY INFORMA'TION DISTRIBUTION SYSTEM (RIDS)
SUBJECT:
Forwards nonproprietary WCAP-12341
& proprietary WCAP-12340, "Westinghouse Improved Thermal Design Procedure Instrument Uncertainty Methodology for CP&L Shearon Harris Nuclear Power State.on."
Rept withheld (ref 10CFR2.790).
DISTRIBUTION CODE:
APOID COPIES RECEIVED:LTR ENCL L SIZE:
TITLE: Proprietary Review Distribution Opera zng Reactor D
/
05000400 NOTES:Application for permit renewal filed.
ACCESSION NBR:9202100263 DOC.DATE: 92/01/29 NOTARIZED: YES DOCKET FACIL:50-400 Shearon Harris Nuclear Power Pla U 't 1, Carolina 05000400 AUTH.NAME AUTHOR AFFXLIATION
~PAP-/Q8 Pi FLOYD,S. D.
Carolina Power
& Light Co.
RECIP.NAME RECIPXENT AFFXLIATXON Document Control Branch (Document Control Desk)
R RECIPIENT ID CODE/NAME PD2-1 LA MOZAFARI,B.
COPIES RECIPIENT LTTR ENCL ID CODE/NAME 1
1 PD2-1 PD 3
3 COPXES LTTR ENCL 1
1 D
D INTERNAL: ACRS OGC/HDS 1 EXTERNAL: NRC PDR 6
6 1
0 OP(
AEOD/DOA E~+f@B 01 1
1 1
1 D
NOTE TO ALL"RIDS" RECIPIENTS:
D D
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATE'OURNAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEEDl TOTAL NUMBER OF COPIES REQUIRED:
LTTR 15 ENCL 13
I
~
S
~
CM0 Carolina Power 8 Light Company SERIAL: NLS-92-033 United States Nuclear Regulatory Commission ATTENTION:
Document Control Desk Washington, DC 20555 SHEARON HARRIS NUCLEAR POWER PLANT DOCKET NO. 50-400/LICENSE NO. NPF-63 SUPPLEMENTAL INFORMATION TO REQUEST FOR LICENSE AMENDMENT REACTOR COOLANT SYSTEM (RCS)
FLOW MEASUREMENT CALIBRATION Gentlemen:
The purpose of this letter is to provide supplemental information to facilitate the NRC's review of a Request for License Amendment submitted by Carolina Power Light Company (CP&L) for the Shearon Harris Nuclear Power Plant (SHNPP) on December 16, 1991.
The proposed amendment would revise Technical Specification 4.2.3.5 concerning the calibration of measurement instrumentation.
Following CP&L's December 16, 1991 submittal, the NRC Project Manager requested that CP&L provide copies of the Westinghouse WCAP (Proprietary and Non-Proprietary versions) that is referenced in the Request for License Amendment.
In response to your request, enclosed are:
1.
One copy of WCAP-12340, "Westinghouse Improved Thermal Design Procedure Instrument Uncertainty Methodology for CP&L Shearon Harris Nuclear Power Station" (Proprietary),
September 1989 One copy of WCAP-12341, "Westinghouse Improved Thermal Design Procedure Instrument Uncertainty Methodology for CP&L Shearon Harris Nuclear Power Station" (Non-Proprietary),
September 1989 3.
Westinghouse Application for Withholding Proprietary Information From Public Disclosure (CAW-92-261) with Affidavit 4.
Copyright Notice 5.
Proprietary Information Notice As WCAP-12340 contains information proprietary to Westinghouse Electric Corporation, it is supported by the affidavit signed by Westinghouse, the owner of the information.
The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4) of Section 2.790 of the Commission's regulations.
7'
~ ~
411 Fayettevilte Street o P. O. Bog 1551 o Raleigh. N. C. 27602 O OO:..
UVc u.
9202100263
'tt20129 PDR ADOCK 05000400 P
t l f0 I
0PI f0 par r<L ~
Accordingly, it is requested that the information which is proprietary to Westinghouse be withheld from public disclosure in accordance with 10 CFR 2.790 of the Commission's regulations.
Correspondence with respect to the copyright or proprietary aspects of the items listed above or the supporting Westinghouse Affidavitshould reference CAW-92-261 and should be addressed to R.
P. DiPiazza, Manager of Nuclear Safety Licensing, Westinghouse Electric Corporation, P. 0. Box 355, Pittsburgh, Pennsylvania 15230-0355.
Please refer any questions regarding this submittal to Mr. R.
W. Prunty at (919) 546-7318.
Yours very truly, S.
D. Floyd Manager Nuclear Licensing Section LSR/isr (1502HNP)
Enclosures cc:
Mr. S.
D. Ebneter Ms.
B. L. Mozafari Mr. J.
E. Tedrow
4
~'