SEP'$.8 1990 Docket No. 50-400 License No.

NPF-63 Carolina Power and Light Company ATTN:

Mr. Lynn W. Eury Executive Vice President Power Supply P. 0.

Box 1551

Raleigh, NC 27602 Gentlemen:

SUBJECT:

FEMA EVALUATION OF THE PROMPT ALERT AND NOTIFICATION SYSTEM FOR THE SHEARON HARRIS NUCLEAR POWER PLANT Enclosed is a

copy of the Federal Emergency Management Agency's Report documenting their analysis of the prompt alert and notification system for the Shearon Harris Nuclear Power Plant which was conducted on July 14, 1987.

As described in the enclosure, FEMA has determined that the alert and notification syste'm installed around the Shearon Harris Nuclear Power Plant satisfies the requirements of NUREG-0654/FEMA-REP-1, Rev.

1, and FEMA 43.

It should also be noted that the caveat on the alert and notification system contained in the March 28, 1989, Title 44

CFR, Part
350, approval of the North Carolina Emergency

Response

Plan site-specific to the Shearon Harris Nuclear Power

Plant, has been removed.

The Governor of North Carolina has been advised of this approval.

FEMA recommends that the State of North Carolina, the local jurisdictions, and the Carolina Power and Light, Company consider increasing the frequency of the full-cycle tests of the Shearon Harris alert and notification system to once a

month.

We encourage you to work closely with the State of North Carolina and the counties within the 10-mile EPZ in testing and maintaining the prompt alert and notification system.

Sincerely,

Enclosure:

(See page 2)

Douglas M. Collins, Chief Emergency Preparedness and Radiological Protection Branch Division of Radiation Safety and Safeguards 9010190244 9OOM8 PDR ADOCK 05000+00 F

PNU

Carolina Power and"Light Company

Enclosure:

FEMA Analysis of Shearon Harris Alert and Notification System cc w/encl:

R.

B. Richey, Manager Harris Nuclear Project Box 165 New Hill, NC 27562 C. S. Hinnant Plant General Manager Harris Nuclear Project Box 165 New Hill, NC, 27562 C.

S. Olexik, Jr., Director Regulatory Compliance Harris Nuclear Project P.

0.

Box.165 New Hill, NC 27562 Richard E. Jones General Counsel Carolina Power 8 Light Company P. 0.

Box 1551

Raleigh, NC 27602 Dayne H. Brown, Director Division of Radiation Protection N.

C. Department of Environment, Health 8 Natural Resources P. 0.

Box 27687 Ra 1 ei gh, NC 27611-7687 c w/encl:

Document Control Desk DRP Section Chief NRC Resident Inspector U.S. Nuclear Regulatory Commission Route 1,

Box 315B New Hill, NC 27562 RII:DRSS cBQs 9a,%go RI I RSS lN ankin

/A/90 RI I: DRP R arroll

/90