ML18009A601

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for June 1990 for Shearon Harris Nuclear Power Plant,Unit 1
ML18009A601
Person / Time
Site: Harris 
Issue date: 06/30/1990
From: Hale M, Richey R
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
HO-903023-(O), NUDOCS 9007190308
Download: ML18009A601 (10)


Text

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9007190308 DOC.DATE: 90/06/30 NOTARIZED: NO FACIL:50-400 Shearon Harris Nuclear Power Plant, Unit 1, Carolina AUTH.NAME AUTHOR AFFILIATION HALE,M.

Carolina Power 6 Light Co.

RICHEY,R.B.

Carolina Power 6 Light Co.

RECIP.NAME RECIPIENT AFFILIATION DOCKET 05000400

SUBJECT:

Monthly operating rept for June 1990 for Shearon Harris Nuclear Power Plant, Unit 1.W/900712 ltr.

DISTRIBUTION CODE IE24D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: Monthly Operating Report (per Tech Specs)

NOTES:Application for permit renewal filed.

05000400 D

A RECIPIENT ID CODE/NAME PD2-1 LA BECKER,D INTERNAL: ACRS AEOD/DSP/TPAB NRQ/~PQ/

B1 0 XTE 01 EXTERNAL: EGGG BRYCE,J.H NRC PDR COPIES LTTR ENCL 3

3 1

1 10 10 1

1 1

1 1

1 3

3 1

1 RECIPIENT ID CODE/NAME PD2-1 PD AEOD/DOA IRM TECH ADV NRR/DOEA/OEAB11 RGN2 LPDR NSIC COPIES LTTR ENCL 1

1 1

1 2

2 1

1 1

1 1

1 1

1 D

D

'D NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE lVASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 29 ENCL 29 gAl A

D D

CPLl Carolina Power 8 Ught Company P. O. Box 165 ~ New Hill, N. C. 27562 R. B. RCHEY Manager Nants Nuclear Project JUL 1

2 1990 File Number:

SHF/10-15505 Letter Number:

HO-903023 (0)

Document Control Desk United States Nuclear Regulatory Commission Washington, DC 20555 HARRIS NUCLEAR PROJECT DEPARTMENT UNIT NO.

1 DOCKET NO. 50-400 LICENSE NO. NPF-63 MONTHLY OPERATIONS REPORT

Dear Sirs:

In accordance with Technical Specification 6.9.1.5 for the Harris Nuclear Power Plant, Unit No.

1, Carol.ina Power

& l.ight Company herewith submits the report of operation stati,sties and shutdown experience for the month of June 1990.

Yours very tru y, R. B. Richey Manager Harris Nuclear Project MWH:mbr Enclosure cc:

Messrs.

E.

D. Ebceter (NRC-RjQ R.

Ge Oehl (DOE)

J.

E. Tedrow (NRC-SHNPP) 900719030S

. 900630 PDR ADOCK 05000400 R

PDC MEiA't'ARVpal', Ot 'l

/

~

~

5

~

~ '

\\ ~

I I

DOCKET NO 050-400 UNIT:

Harris Unit 1

DATE:

June 1990 COMPLETED BY:

Mark Hale OPERATIONS

SUMMARY

Harris Unit 1 operated at a

100 percent Availability Factor for the referenced month and a

94.11 percent Capacity Factor.

There was one continued event.

Details are provided on the Unit Shutdowns and Power Reduction Sheet.

There are 157 fuel assemblies in the reactor vessel and 266 spent fuel assemblies in the Spent Fuel Pools.

162 of..the spent fuel, assemblies are BWR and were shipped to Harris from CP&L's Brunswick Plant.

MEM/DATAREPa/1/OS4

CF'M Co

~

RLJN DATL.

i 'RLJ'N 1'IHE PLAN1'Ef<FORHANCE DATA AUSTEN 87/86/98 ~

opERATxNG 1)ATA I<Ep~

14:42:41 HAf<f<IS UNIT F'AGE r(pD36-ee<>

OPEftATING B1'ATLJS DQCI<ET No. 850-408 COHF'LETED K<Y NARY.

M ~

HALE 1'ELEPHONE (91 l)362-2944

.l A 3.

5.

6.

7.

8 ~

UNXT NAHE:

I.IARfhxs UN11'EI"ORTING I='I=IRXOD:

JUNI=

90 LICENSED THERNAL F'OMER (HMT>: 2775 NAHI-=PLArE RA rxNG

<GRoss NME): 95e.9 1)ESXGN ELECTRlCAL RAT3:NG (NE'I'ME): 988*8 HAX DEPENDABLE CAPACITY (GROSS HME):

9 0.8 NAX DEPENDAI<LE CAF'Acl:1'Y (NET HWE):

868 F 8 II= CHANGLB OCCUR IN CAPACI1'Y RATINGS (XTENS GJVE REASONS:

NA I

NOTFS There are 157 fuel assem-I I

blies in the reactor, 266 spent I

fuel assemblies in Spent Fuel I

I

Pools, 162 of the spent fuel I

assemblies are BWR and were I

I shipped from Brunswick.

I 3

TIIRU 7>

SXNCE LAST REI (3RT, 10.

POMEI'C LEVI=L To MHXCH RESTRICTL'D XF ANY (NET HWE): none f(EABONS FOR RESTf<XCl'XON XF ANY: NA rHxs MONTH YR ro DATE CUHUL ATXVE 13*

14.

15*

16.

17

'8.

19.

, P)0 21 k

~

23.

HOURS IN,REPORTXNG PERIOD NuHriER ol= HouRs RI='AcroR cRxlxcAL REACTOR RESERVE SHUTDOWN HRB IIOURS GENERATOR (3N LINE LJNXT RESERVE SHLJTDOWN HOURS GROSS TIIERHAL ENERGY GEN.

(HMH)

GROSS ELEC.

ENERGY GEN.

(NMI-I)

NET LI E(

  • ENER( Y GENERATED (HWH)

LJNI1'ERV3:CE FACTOR UNIT AVAILABILITYFACTOR UiNlT CAF'.

FACTOR

<USXNG HDC NE1')

LJNXT CAP.

FACTOR (USXNG DER NE'I)

UNIT FORCED OUTAGE RATE Bl IUTDOWNB BCI.IED.

OVER NFX'I' HONTHS 728.88 720.08

.88 r28.88

.80 1985(>33

~ 06 622947.00

,582718.00 18<). 88 188.00 89.93

.00 (TYPE, DA1'E, 4343 80 4075.97

.08 4(>58. 28 00 18573689.86 3531813 80 32'~5281.00 93.44 93.44 88.23 84.31 3.16 AND DURATION 27744.00 228 73*54

.88 21717.63

.88 57115367.46 18982075.80 17633449.88 78.28 78.28 73 ~ 9<)

78.62 4.62 OF EACH):

XF BHLJTDOWN AT END OF REPORT PEf<xol),

ES1'1NATED DA1'E OF STAf<T LJF':

UNITS xN.rEsT srArus

<I-RIOR ro CONHERCXAL OPERA'rxoN>:

I=ORECAB1 AcHxEVLD INITXAL CRlTICALXTY INlTIAI ELECTRICITY COHNEf<c XAL OF'ERAT 3: ON MEM/DATAREPa/2/OS4 1.16 9

'I 4

I

CP6L" CO PLAHT PERFORHAHCE DATA ~TEM ARUN DATE 07/Oh/9()

%~1"=NDIX 8 AVERAGE DAILY IVER LEVEI

~., RUH T IHE 1 4: 42: 38 HARRIS UNIT 4

PAGE RPD39-()ee DOCI(ET HO. ()50-400 COHPLETED BY NARK M.

HALE TELEPHONI= (919)362-2944 DAY AVG. DAILY POWER I EVI=I

( HME-HE'I')

DAY AVG. DAILY POWER LEVEL (NME-HET) 855 20 t72 851 85 861 854 85$

859 30 MEM/DATAREPa/3/OS4

).It m

t It I

r V'l II I

f I

t I

Ii It il t it II

~V II l tt V

w

~ t

>> ~

I ~

~

I

~

~

\\ ~

~

~

I

~

~

~

~ ~

~

~

~

~

I ~

~ ~

~ '

~

~

'I I ~'I

~

~

~

~

I

~

I '.

~

~

a ~

~

~

~

~ ~

~

~

~

~ ~ I

~

~

~

~

~

I

~

~

~

I I

-~,

~

~

~

~

~

~

~

~ ~

I

~

I I

~

l ri

\\

c t'