ML18009A333

From kanterella
Jump to navigation Jump to search
Special Rept:On 891220,plant Vent High Range Noble Gas Monitor RM-21AV-3509-1SA Declared Inoperable When Monitor Found to Be Out of Calibr During Performance of Test Procedure.Caused by Detector Being Out of Calibr
ML18009A333
Person / Time
Site: Harris 
Issue date: 01/05/1990
From: Richey R
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
HO-900002-(O), NUDOCS 9001160281
Download: ML18009A333 (3)


Text

ACCELERATE)

UTION DEMONS'ATION SYSHM REGULATORY INFORMATXON DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9001160281 DOC.DATE: 90/01/05 NOTARIZED: NO FACIL:50-400 Shearon Harris Nuclear Power Plant, Unit 1, Carolina AUTH.NAME AUTHOR AFFILIATION RICHEY,R.B.

Carolina Power

& Light Co.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Special rept.:on 891220,operability of radiation monitor.

DXSTRIBUTION CODE:

IE22D COPXES RECEIVED:LTR ENCL SIZE:

TITLE: 50.73/50.9 Licensee Event Report (LER), Inciden Rpt, etc.

NOTES:Application for permit renewal filed.

DOCKET 05000400 05000400 RECIPIENT ID CODE/NAME PD2-1 LA BECKER, D XNTERNAL: ACRS MXCHELSON ACRS WYLIE AEOD/DSP/TPAB DEDRO NRR/DET/EMEB9H3 NRR/DLPQ/LHFB11 NRR/DOEA/OEABll NRR/DST/SELB 8D NRR/DST/SPLB8D1 NUDOCS-ABSTRACT RES/DSIR/EIB EXTERNAL: EGGG WILLIAMS,S LPDR NSIC MAYS,G NUDOCS FULL TXT COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 4

4 1

1 1

1 1

1 RECIPIENT ID CODE/NAME PD2-1 PD ACRS MOELLER AEOD/DOA AEOD/ROAB/DSP NRR/DET/ECMB 9H NRR/DET/ESGB 8D NRR/DLPQ/LPEB10 NRR/DREP/PRPBll NRR/DST/SICB 7E 8E REG FXLE RGN2 02 L ST LOBBY WARD'RC PDR NSIC MURPHY,G.A COPIES LTTR ENCL 1

1 2

2 1

1 2

2 1

1 1

1 1

1 2

2 1

1 1

1 1

1 1

1 1

1 1

1 1

1 NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTEI CONTACTTHE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISIRIBUTION LISIS FOR DOCUMENTS YOU DON'T NEEDl TOTAL NUMBER OF COPIES REQUIRED:

LTTR 38 ENCL 38 gI'

Carojjna Power 8 Ught Compan P. Q. Box t65 ~ New Hill, N. C. 27562 A. B. AlCHEY Manager Hanle Nuclear Project JAN -5 ig90 Letter Number.'HO-900002 (0)

United States Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, DC 20555 HARRIS NUCLEAR PROJECT UNIT 1 DOCKET NO. 50-400 LICENSE NO. NPF-63 NRC 14-DAY SPECIAL REPORT In accordance with Technical Specifications 3.3.3.6 and 6.9.2 for the Shearon Harris Nuclear Power Plant, Unit No.

1, Carolina Power

& Light Company hereby submits this Special Report.

This Special Report concerns the operability of a radiation monitor.

Very truly yours, R.

B. Riche/

Ma ager Harris Nuclear Project RBR:dgr Enclosure cc.'r.

R. A. Becker (NRR)

Mr. S.

D. Ebneter (NRC - RII)

Mr. J.

E. Tedrow (NRC - SHNPP) 9001160281 900105 PDR AGOCK 06000400 9

PDC MEM/HO-9000020/1/OS1

ACCIDENT RADIATION MONITOR SPECIAI REPORT Descri tion of Event On December 20, 1989 at 07:47, the Plant Vent High Range Noble Gas Monitor ARM-21AV-3509-1SA was declared inoperable when the monitor was found to be out of calibration during performance of test procedure MST-I0376, Plant Vent Stack Accident Monitor RM-21AV-3509-1SA Calibration.

This monitor is identified in the Harris Technical Specification Table 3.3.10 as Item 18.

The compensatory actions required by Technical Specification 3.3.3.11 to allow continued effluent releases are'(1) grab sampling every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and (2) continuous sampling with auxiliary sampling equipment.

These compensatory actions were performed while the monitor was inoperable.

The monitor was out of service for greater than 7

days, thus, a

Special Report is required to be submitted per the Technical Specifications.

Cause/Corrective Action On December 19, 1989, Monitor ARM-21AV-3509"1SA was taken out of service to perform MST-I0376.

The monitor failed the MST on December 20,

1989, due to the low range detector being out of calibration.

On December 21,

1989, radiation control personnel completed a

primary calibration on the monitor.

On December 26 1989, while preparing to reperform MST-I0376, a

separate problem was identified with the low range detector flow being too low.

On December 28,

1989, the low range flow pump was replaced to correct the problem.

RM-21AV-3509-1SA has been successfully tested per MST-I0376 and was declared operable on December 29, 1989.

MEM/HO-9000020/2/Osl