ML18008A293
| ML18008A293 | |
| Person / Time | |
|---|---|
| Site: | 07000036 |
| Issue date: | 01/04/2018 |
| From: | Westinghouse |
| To: | Office of Nuclear Material Safety and Safeguards |
| JASmith NMSS/DUWP/MDB 415.6103 T5B88 | |
| Shared Package | |
| ML18008A291 | List: |
| References | |
| LSA 08-10 | |
| Download: ML18008A293 (2) | |
Text
Survey Unit No.:
Activity (xi)
MDC Activity (xi)
MDC L08-10-16-T-S-S-00 L08-10-16-T-S-Q-00 Ra-226 0.532 0.129 0.8 0.0603 0.666 1.9 0.268 0.269 0.403 N
L08-10-16-T-S-S-00 L08-10-16-T-S-Q-00 Tc-99 1.87 0.215 3.86 0.22 2.865 25.1 1.99 3.552 5.321 N
L08-10-16-T-S-S-00 L08-10-16-T-S-Q-00 Th-232 0.73 0.0843 0.718 0.0765 0.724 2.0 0.012 0.283 0.424 N
L08-10-16-T-S-S-00 L08-10-16-T-S-Q-00 U-2341 0.445 N/A 4.189 N/A 2.317 195.4 3.744 27.649 41.425 N
L08-10-16-T-S-S-00 L08-10-16-T-S-Q-00 U-235 0.0167 0.411 0.231 0.164 0.124 51.6 NA 7.301 10.939 NA L08-10-16-T-S-S-00 L08-10-16-T-S-Q-00 U-238 0.887 0.672 0.999 0.725 0.943 168.8 0.112 23.885 35.786 N
Comments:
- 1. U-234 is inferred, no MDC available.
- 2. Duplicate assessment is not necessary if the result of either sample is < MDC.
Performed by:
Reviewed by:
Date:
Date:
Quality Record FIELD DUPLICATE SAMPLE ASSESSMENT LSA 08-10 Survey Unit
Description:
Central Open Land Area in "Area 6" Average Activity ( )
(pCi/g)
Nuclide DCGL (pCi/g)
Statistic2 Warning Limit Control Limit Statistic Exceeds Limit?
(Y/N)
Sample ID Field Duplicate Sample ID Radionuclide Sample (pCi/g)
Field Duplicate Sample (pCi/g)
FORM HDP-PR-FSS-703-1 Hematite Decommissioning Project Procedure: HDP-PR-FSS-703, Final Status Survey Quality Control Revision: 2 Page 1 of 1
LSA 08-10 Sys SOF Only 0.0 0.0 0.1 0.4 0.3 0.2 0.1 0.9 0.2 0.3 0.1 0.7 0.2 0.1 0.0 0.0 0.3
v4.65.2 Last updated 7 July 2017 at 6:30 by W. Clark Evers Descriptives N
17 Mean 95% CI Mean SE SD Variance LSA 08-10 Sys SOF Only 0.22 0.10 to 0.35 0.058 0.24 0.06 Minimum 1st quartile Median 95.1% CI 3rd quartile LSA 08-10 Sys SOF Only 0.0 0.07 0.18 0.08 to 0.26 0.27 Distribution: LSA 08-10 Sys SOF Only Sheet1 A1:A18 0
1 2
3 4
5 6
7 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Frequency LSA 08-10 Sys SOF Only 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
LSA 08-10 Sys SOF Only
Skewness Kurtosis 1.8 2.86 Maximum IQR 0.9 0.20