Requests Certification for Each Proposed Tech Spec Exception to Be Granted Under Generic Ltr 87-09 That Remedial Measures Prescribed for Affected Action Statements Consistent W/ Updated FSAR & Supporting Safety Analyses
ML18005A999
Person / Time
Site: Harris 
Issue date: 07/13/1989
From: Becker R
Office of Nuclear Reactor Regulation
To: Eury L
CAROLINA POWER & LIGHT CO.
References
GL-87-09, GL-87-9, TAC-68339, NUDOCS 8907190072
Download: ML18005A999 (4)


Text

~R Rfgy

~o Oj)

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 July 13, 1989 Docket No. 50-400 Mr. Lynn W. Eury Executive Vice President Power Supply Carolina Power 5 Light Company Post Office Box 1551

Raleigh, North Carolina 27602

Dear Mr. Eury:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION ON THE LICENSEE AMENDMENT APPLICATION UNDER GENERIC LETTER 87-09 FOR SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1 (TAC NO. 68339)

By 1etter dated November 9, 1987, Carolina Power 8 Light Company (CPSL, applied for changes to the Shearon Harris Nuclear Power Plant, Unit 1, (Harris Technical Specifications (TS) pursuant to Generic Letter (GL 87-09) regarding:

TS Sections 3.0 and 4.0.

The NRC staff is reviewing this application and finds that additional information is needed to complete our review.

The basis for accepting Specification 3.0.4-related amendments under GL 87-09 is predicated on two assumptions:

1) that the remedial measures prescribed by the TS ACTION STATEMENTS for which the exception will be granted provide a sufficient level of protection to permit operational mode changes and safe long-term operation consistent with the licensing basis described in the Updated Final Safety Analysis Report (UFSAR) for Harris; and 2) that it wi 11 be the exception when plant startup commences to have important safety features inoperable, irrespective of the exceptions granted in response to applications under GL 87-09.

Therefore, in order for the NRC staff to conclude that the safety basis relative to the above stated assumptions is satisfied, we request that for each proposed TS exception to be granted under GL 87-09, you certify that remedial measures prescribed for the affected ACTION STATEMENTS are consiste'nt with the UFSAR and its supporting safety analyses.

In addition, we request that you identify those administrative controls (e.g.,

maintenance program provisions, plant operating procedures, management directives, onsite safety reviews, etc.)

that have been established to limit the use of the Specification 3.0.4 exceptions granted and certify their imp'Iementation.

Your certification should address training necessary for ensur ing that plant operators are made-aware of, and are instructed to exercise, the controls promulgated in limiting the use of such exceptions.

3907 190072 390713 PDR AOOCK 05000400 PDC (0

I

Nr. Lynn W. Eury July 13, 1989 Please advise, within five days after receipt of this letter, when we may expect to receive your response.

Should there be any questions concerning this request, please let me know.

The request in this letter affects fewer than ten respondents; therefore, ONB clearance is not required under P.L.96-511.

Sincere ly, ii Original Signed By:

cc:

See next page Richard A. Becker, Project Hanager Project Directorate II-1 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation DISTRIBUTION Docket F-i le NRC 5 Local PDRs

'DI I-1 Reading

SVarga, 14/E/4 GLai nas, 14/H/3 PAnderson RBecker OGC -(info. only)
EJordan, 3302HNBB
BGrimes, 9/A/2 ACRS (10)

EAdensam

[SH L

RAI LTR]

LA' PAn n

07/ fi/89 PH:

I -1 R:

d 07/]z/89 EAden sam 07/ ) /89

I'I li

.Il II I

8

~ l I'l e'I'l

~

II

~

II

'I l

II ll li Ii I

lt I

I l"

Ill 1

II III l~

I

)

I I

Ill I

~ v li II e

I

Mr. L. ll. Eury Carolina Power 8 Light Company Shearon Harris CC:

Mr.

R.

E. Jones, General Counsel Carolina Power 5 Light Company P.

0.

Box 1551

Raleigh, North Carolina 27602 Resident Inspector/Harris NPS c/o U. S. Nuclear Regulatory Commission Route 1,

Box 315B New Hill, North Carolina 27562 Mr. R.

B. Richey Manager - Harris Nuclear Project Harris Nuclear Plant P. 0.

Box 165 New Hill, North Carolina 27562 Mr. H. A. Cole Special Deputy Attorney General State of North Carolina P.

0.

Box 629 Raleigh, North Carolina 27602 Nuclear Energy Public Information Committee c/o Triangle J Council of Governments P.

0.

Box 12276 Research Triangle Park, NC 27709 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street Suite 2900 Atlanta, Georgia 30323 Mr. C. S. Hinnant Plant General Manager Harris Nuclear Plant P. 0.

Box 165 New Hill, North Carolina 27562 Mr. Dayne H. Brown, Chief Radiation Protection Section Division of Facility Services N.

C. Department of Human Resources 701 Barbour Drive Raleigh, North Carolin'a 27603-2008