gccp~~yED DJSPBUTloN DEMONsTRQ]0.'i SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:8902240288 DOC.DATE: 89~~

NOTARIZED: NO FACIL:50-400 Shearon Harris Nuclear Power Plant, Unit 1, Carolina AUTH.NAME AUTHOR AFFILIATION HALE,M.W.

Carolina Power

& Light Co.

WATSON,R.A.

Carolina Power

& Light Co.

RECIP.NAME RECIPIENT AFFILIATION DOCKET N

05000400 S

05000400 NOTES:Application for permit renewal filed.

SUBJECT:

Monthly operat' for Jan 1989 for Harris Nuclear Power Plant, Unit 1. /89021 ltr.

DISTRIBUTION CODE:

IE24D COPIES RECEIVED:LTR L ENCL SIZE:

TITLE: Monthly Operating Report (per Tech Spec

)

RECIPIENT ID CODE/NAME PD2-1 LA BECKER,D INTERNAL: ACRS AEOD/DSP/TPAB NRR/DLPQ/PEB 11 EXTERNAL: EG&G SIMPSON, F LPDR NSIC COPIES LTTR ENCL 1

0 1

0 10 10 1

1 1

1 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME PD2-1 PD N

AEOD/DOA ARM TECH ADV NRR/DOEA/EAB 11 NUDOCS-ABSTRACT RGN2 EG&G WILLIAMS,S NRC PDR COPIES LTTR ENCL 5

5 1

1 2

2 1

1 1

1 1

1 1

1 1

1 R

I A

NOTE 'IO ALL "RIDS" RECIPZERIS'IZASE HELP US 'IQ REXJCE HASTE.'ONTACT 'IEE DOCUMEMI'XÃTROLDESK, ROOM Pl-37 (EXT. 20079) K) EIRUINATE KER NMK FMH DISTIKBUTIGN LISTS FOR DOCKMWZS YOU DON'T NEEDt TOTAL NUMBER OF COPIES REQUIRED:

LTTR 32 ENCL 30

4

DOCKET NO.:

050-400 UNIT:

Harris Unit 1

DATE:

January 1989 COMPLETED BY:

Mark Hale OPERATIONS

SUMMARY

Harris Unit 1 operated at a 96.05 percent Availability Factor for the month of January with a

95.18 percent capacity factor.

There was one maintenance

outage, one reactor trip, and two, load reductions.

Details are provided on the Unit Shutdowns and Power Reduction Sheet.

There are 157 fuel assemblies in the reactor vessel and 52 spent fuel assemblies in the Harris Unit 1 spent fuel pool and 0 assemblies in the new fuel pool.

8902240288 890131 PDR ADOCK 05000400 R

PDC MEM/DATAREpa/g/OS4

~

~

,f

CF'll

. CO RUN DATE 02/06/89 RUN TIME 88: 32: 2$ t Pl AHT PERFORMANCE DATA SY~.N OPERAT1HG DATA REPORT~

I-IARR IS UNIT PAGE RPD36-000 OPERATING STATUS DOCKET HO. 858-408 CONF'LETED BY HARK M.

HALE TELEF'I-IGNE, (939)362-2944 J

~

J 3*

4.

5

  • 6.

7 J 8.

UHIT NAME:

I IARR IS UNIT I

NOTES I'EPORTIHG PERXGD:

JANUARY 89 There are 157 'fuel assemblies in LXCEHBED THERNAI POWER

<MMT): 2775 the reactor and 52 spent fuel

< GROSS NWE >.

950 9

~

assemblies in the spent fuel pool~

DESIGN ELECTRICAL RATING (NET MME): 988 0

I I

MAX DEPENDABLE CAPACITY <GROSS NME): 928.8 I

I MAX DEPENDABLE CAF'ACITY <HET MWE): 860.0 IF CHANGES OCCUR IN CAPACITY RATINGS (1TEMS 3 Tl-IRU 7)

SINCE LAST REPORT, GIVF REASONS:

g/A V

9 18.

POWER LEVEL TG WHICH RESTRICTED IF AHY (NET NME>: gone.

REASONS FOR RESTRICTION IF ANY:

Tl-IXB MONTH YR TQ DATE CUMUL ATIVE

~

J 13*

14.

$ 5.

16.

17.

18.

20.

21 J

1 ".)

J J>>J 23 J 24 HOURS IN REPORTING F'ER IOD NUMBER OF HOURS RFACTOR CRI1'1CAL REACTOR RESERVE Sl-IUTDOWH I-IRS HOURS GENERATOR QN LINE UNIT RESERVE Sl-IUTDQWN HOURS GROSS 1'HERMAL ENI=RGY GEH.

(MWH>

GROSS ELEC.

ENERGY GEN.

(MWH)

NET ELEC.

EHERGY GENERATED (MWH)

UNIT SERVICE FACTOR UNIT AVA1LABILX7 Y FAC1'OR UNIT CAP.

FACTOR (USING MDC NET)

UNIT CAP.

FACTOR (USIHG DER NET>

UNIT FORCED OUTAGE RATE SI.IUTDOWHB SCHED.

OVER NEXT 6 MOHTI-IS 744.88 734.97

.08 714.63

.80 1939358.78 651899.88 608992.88 96.85 96 F 05 95.18 90.95 3.95 (TYPE,

DATE, 744.80 734.97

.88 714.63

.80

$ 939358.78 651899.00 608992.00 96.05 96.05 95.18 98*95 3.95 AND DURATIQN 15385.88 11769.97

.88 31498.86

.00 38188821.76 18851686.88 9315388.88 74.74 74.74

78. 40, 67.28 6.64 GF EACH):

25.

IF SHUTDOWN AT END QF REF'GRT F'FRIOD, FSTIMATED DATE QF START UP:

UNITS IH 1EBT B1A1US

<PRIOR TO COMMLRCIAL OPERATION):

FORECAST ACHIEVED IHITIAI CRITICAI ITY INXTIAI. ELECTRICITY COMMERCIAL GF'ERATIOH MEM/DAREPa/4/OS4 rc >0 l

1

Ct='i)L.C.O RUN DATE 02/06/89 RUN TIHF 08: 32: 5 9

~~LANT PERFORHANCE DATA SYPH AF'BENDIX.B AVERAGE DAILY F'O~

LEVEL HARRIS UNIT PAGE RPD39-000 JANUARY DAY AVG. DAILY O'OMER LEVEL (HWE-NET)

DOCKET NO. 050-400 CQHF'LETED BY HARK M..

HAI E TELEF'HONE (93 9) 362-2944 DAY AVG. DAILY POWER I FVEL (HME-NET) 218 879 884 2e 860 871 7

889 883 867 884 884 877 SS6 870 538

,24 26

.)7 28 870 876 870

$.16 8

MEM/DATAREPa/5/OS4

~

~

I'l

~ =

~

~

\\

~

I ~

~

~

I ~ 5 I

I I

II

~

~

\\

~

~

\\

~

~

I

~

~

I ~

~

~

~

~

I ~

~ t

~

~

~

~

~

I

~

~

~ I1

~

~

~

~

~

~

~

~

~

~

~

~

~

I I

4 I

~

~

~

~

~

~

~ ~

~

~

~

I

~

~

~.

~

~

I I ~

I

. ~;

~

I ~.;

~

~

~ '

I

~

~

I I

~

I I

4 lj

I ~

~

~

I II I

I II

~

~

~I I

I

~

~

~

~

~

~

~

~

~

~

~ t

~ ~

~

~

~

~

I ~

I ~

I ~

I

~

~ I

~

~

o

~

~ I '.

~

~

~

~

~

~ ~

~

~

1

~

~

~

~

I ~

~

~

~

I ~

~

~

~

I

~ ~

I

.~;

~

~

~.

~

~

~

I

~

~

I I ~

~

~

1 F

I

~

~

~"

I ~

I

~

I

~

~ ~

I I

I 'll

~

~

~

~

~

~

~

~

~

~

I

~

~

~ ~

~

~

~

~

I ~

I 'I

~

I ~

~

~

~

~

~

~

~

~

~

~

I

~

~

~

I ~

~

~

~

~

~

~

~

~

~

~

~

~

I

~

~

~

I

~ ~

I

~

~

~

~

~..

~

~

~

I

~

~

I I ~..

~

~

~

~ ~

C

~

~

0

'b

~ ~ ~

I I I II

~ I I

I

~

~

~

~

0

~

I

~

~

~ ~

~

~

~

~

~ ~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ '

~ '

~

~

~ '

~

~

~

~

~

~

~

~

~

~

~

~

~

~

I I ~

I It

~

~

I

~

~

~

~

~

~

I '

a

~

E A

<r.

s

'E

,~

4 Carolina Power & Light Company HARRIS NUCLEAR PROJECT FEB 14 1989 File Number.'HF/10-15505 Letter Number:

HO"893003 (0)

Document Control Desk United States Nuclear Regulatory Commission Washington, D. C.

20555 HARRIS NUCLEAR PROJECT DEPARTMENT UNIT NO.

1 DOCKET NO ~ 50-400 LICENSE NO. NPF-63 MONTHLY OPERATIONS REPORT Dear Sirs'.

In accordance with Technical Specification 6.9.1.5 for the Harris Nuclear Power Plant, Unit No.

1, Carolina Power

& Light Company herewith submits the report of'peration statistics and shutdown experience for the month of January 1989.

Yours very truly, g~~~v R. A. Watson Vice President Harris Nuclear Project MWH:msb Enclosure cc:

Messrs.

W. H. Bradford (NRC-SHNPP)

M. L. Ernst (NRC-R1I)

R. G. Oehl (DOE)

J.

M. Taylor (NRC)

MEM/DATAREPa/1/OS4

4 t.

~

5 5 g'1",