Download: ML18004B669 (3)


Text

~l E'CCESSION NBR:

FACIL:50-400 AUTH. NA}'}E CUTTERS A. B.

REC IP. NANE DENTON> H. R.

REQC TORY INFOR}'}ATIONDISTRIBU N SYSTEN (RIDS) 8701120262 DQC. DATE: 87/01/05 NOTARIZED:

NO DOCKET Shearon Harris Nuclear Pover Pianti Unit 1> Carolina 05000400 AUTHOR AFFILIATION Carolina Potuer 8< Light Co.

RECIPIENT AFFILIATION Office of Nuclear Reactor Regulation~

Director (post 851125

SUBJECT:

Forwards investigative test results conducted on Phillips expansion anchors>maxibolt expansion anchors k emergency svc water intake structure shear p lates> in response to CASH/

Eddleman allegations.

DISTRIBUTION CODE:

YEOSD COPIES RECEIVED: LTR g ENCL J SIZE:

~ +

TITLE: Request f'r NRR Action (e. g.

2. 206 Petitions)

Zc Related Correspondenc NOTES: Application for permit reneu!al filed.

05000400 REC IP IENT ID CODE/NA}'}E PMR-A PD2 LA BUCKLEY'S B 01 INTERNAL EDO/ACB ELD/RED COPIES LTTR ENCL 1

1 1

1 REC IP IENT ID CODE/MANE PWR-A PD2 PD ELD/HDS1 NRR DIR COP IES LTTR ENCL 1

EXTERNAL: LPDR NSIC 03 05 1

1 NRC PDR 02 TOTAL NU}'}BER OF COPIES REQUIRED:

LTTR 11 ENCL 11

0 l

I II

CNK Carolina Power & Light Company SERIAL:

NLS-8 7-002 January 5,

1987 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation United States Nuclear Regulatory Commission Washington, DC 20555 SHEARON HARRIS NUCLEAR POWER PLANT DOCKET NO. 50-400/LICENSE NO ~ NPF-53

'FURTHER INVESTIGATIVE TESTING

Dear Mr. Denton:

On December 15, 1986, Carolina Power

& Light Company (CP&L) filed "Licensees'esponse to CASH/Eddleman Show Cause Petition" (10 CFR 2.206) which is fully responsive to the allegations raised by petitions and demonstrates that Petitioners have not presented any cogent evidence of the existence of significant health and safety issues at the Harris Plant.

Nevertheless, in order to further refute the basis for Petitioners'llegations, CP&L initiated additional testing, although such tests were not required to resolve the allegations.

Attached are the results of further investigative tests conducted on Phillips Expansion Anchors (Attachment 1), Maxibolt Expansion Anchors (Attachment 2),

and Emergency Service Water Intake Structure Shear Plates (Attachment 3).

This information should be considered a supplement to CP&L's December 15, 1986 response.

Each of the investigative tests further demonstrates that there are no health and safety concerns with respect to these Petitioner's allegations.

Yours very tru A. B. Cutter Vice Pre ident Nuclear Engineering

& Licensing ABC/SRZ/crs (SRZ-28) cc:

Mrs BE C. Buckley (NRC)

Dr. J. Nelson Grace (NRC-RII)

Mr. G. F. Maxwell (NRC-SHNPP)

(

8701120262 870105 PDR

  • DOCK 05000400 P

PDR 411 Fayettevilte Street

~ P. O. Box 1551

~ Raleigh. N. C. 27602

'I&