'EGULA'NFORMATION,DISTRIBUTI

~YSTEN (R IDS)

ACCESSION NBR: 8604280229 DOC. DATE: 86/04/23 NOTARIZED:

NO DOCKET 8 FACIL:50-400 Shearon Harris Nuclear Power Plantp Unit 1 p Carolina 05000400

'UTH. NAl"lE AUTHOR AFFXLIATION ZINMERl>ANpS. R.

Carolina Power Cc Light Co.

REC IP. NANE RECIPIENT AFFILIATION DENTONp H. R.

Dppice op Reel ear Reactor Regulation.. Dirac to'r (poet SSIISB api C

Pc g)

SUBSECT:

Poruardo proprietarg "Sapetg Evaluation For.Operation op

,Shearon Harris to/positive moderator coefficient."

SER should be revised to incorporate new analyses.

Encl toithheld.

DISTRIBUTION CODE:

B001D COPXES RECEIVED: LTR ENCL SIZE:

TITLE: Licensing Submittal:

PSAR/FSAR Amdt s 5 Re lated Correspond en c'e NOTES: Application for permit renewal filed.

05000400 RECIPIENT COPIES ID CODE/NANE LTTR ENCL PWR-A ADTS f/'"

PWR-A EICSB,IO 2

2 PWR-A PD2 LA gg il 1

BUCKLEY B

@ IZ)l~ 2 2

PWR-A RSB Pif 1

1 RECIPIENT ID CODE/NANE

'WR-A EB P'7 PWR-A FOB Qb PWR-A PD2 PD AS'WR-A PSB COP XES LTTR ENCL 1

1 1

1 1

INTERNAL: ADN/LFNB IE FXLE gl$

IE/DGAVT/GAB Q(@

NRR PWR-A *DTS NRR ROE, N. L NRR/DHFT/NTB

/if'QNR

@fcllyal EXTERNAL: 24X DNB/DSS (ANDTS)

NRC PDR 02 PNL QRUEL. R 1

0 1

1 0

1 1

1 4/f ELD/HDS1 IE/DEPER/EPB gj NRR BWR ADTS NRR PWR-B ADTS NRR BF IB~"I RtPDDANI/RIB BNL(ANDTS ONLY)

LPDR 03 NSIC 05 0

0.

1 0

1 0

TOTAL NUllBER OF COPIES REQUIRED:

LTTR 34 ENCL 28

I<<P P<<P~<<1 <<Pl'N

<< t'P 0

<<L] t$,<<

"II > ~ j()kf I'"I $

~

II I

'I r >It tl g "

Ig i

Pt/

"I II)

I 1",. I<<'t I ~

l I

tl jill,'

tr lt i

II

~

P I

I P

H

SINK Carolina Power & Light Company APR 3 3 1986 SERIAL: NLS-86-110

,Mr. Harold R. Denton, Director'Office of Nuclear Reactor Regulation United States Nuclear Regulatory Commission Washington, DC 20555 SHEARON HARRIS NUCLEAR POWER PLANT UNIT NO.

1 DOCKET NO.50-000 MODERATOR TEMPERATURE COEFFICIENT

Dear Mr. Denton:

The Shearon Harris Nuclear Power Plant (SHNPP) Final Safety Analysis Report (FSAR) as currently written, assumes a non-positive moderator temperature coefficient (MTC) in a number of the safety analyses.

However, during the start up procedure preparation process and through contact with other utilities, Carolina Power 2 Light Company became aware of the potential for a positive MTC at less than full power. Carolina Power R Light Company initiated an evaluation and reanalysis of plant transients for which a positive MTC is non-conservative to prevent power restrictions during the early stages of core life. The results of the reanalysis are presented in this letter and demonstrate that the safety analyses remain within safety limits assuming a positive MTC.

The potential for a positive MTC arises from the SHNPP core configuration which includes a light (low reactivity worth) control bank D. The normal procedure utilized to maintain a non-positive MTC is control bank D insertion, however, there is insufficient negative reactivity to adequately maintain a non-positive MTC during ascension to power.

A summary of the analyses performed in support of a positive MTC is provided in. This summary addresses each FSAR Chapter 15 transient and either provides justification for not performing a reanalysis or a brief summary of the analysis and conclusions. provides a mark-up of the affected FSAR pages which willbe included in a future FSAR amendment. provides a mark-up of the affected Technical Specification (TS) pages to be included in the TS prior to issuance of an operating license.

Carolina Power R Light Company requests you review this information as soon as possible and revise the Safety Evaluation Report to incorporate this new analysis.

8604280229 8b0423 PDR

  • DOCK 05000400 E

PDR 411 Fayettevilte Street

~ P. O. Box 1551

~ Raleigh, N. C. 27602 Boo l t/

If you have any questions on this subject, please contact David McCarthy at (919) 362-2010 or (919) 836-7715.

Yours very truly, pV~~

S.. Zi merman ager Nuclear Licensing Section SRZ/3DK/ccc (36063DK)

Attachments cc:

Mr. B. C. Buckley (NRC)

Mr. G. F. Maxwell (NRC-SHNPP)

Dr. 3. Nelson Grace (NRC-RII)

Mr. Travis Payne (KUDZU)

Mr. Daniel F. Read (CHANGE/ELP)

Wake County Public Library Mr. Wells Eddleman Mr. John D. Runkle Dr. Richard D. Wilson Mr. G. O. Bright (ASLB)

Dr. 3. H. Carpenter (ASLB)

Mr. 3. L. Kelley (ASLB)

I r

ATTACHMENT 1 to NLS-S6-110 (3646 JDK/mrs )