ML18003A922

From kanterella
Jump to navigation Jump to search
Forwards Open Items List of Resolve Questions Re Quality Group Classification to Be Included in Draft SER as Subitems of Section 17.5
ML18003A922
Person / Time
Site: Harris  
Issue date: 06/07/1983
From: Knighton G
Office of Nuclear Reactor Regulation
To: Utley E
CAROLINA POWER & LIGHT CO.
References
NUDOCS 8306240467
Download: ML18003A922 (7)


Text

7 88>

4 Docket Nos.:

50-1300 and 50-401 I<r. E. E. Utley Executive Vice President Carolina Power

5. Light Company Post Office Box 1551 Raleigh, North Carolina 27602 DISTRIBUTIOII

. Document Control 50-400/401 NRC PDR L

PDR NSIC PRC System I B83 Reading

-" JLee NPKadambi

Attorney, OELP TMNovak JSpraul RKirkwood ACRS (16)

Dear Vial. Utley:

Subject:

Request for Additional Information - Shearon Harris The review of Table 3.2.1-1 of the Shearon Hurris FSAR by the Mechanical Envineering Branch has revealed additional items regarding which information is required to resolve questions of guality Group classification.

Enclosed is a listing of the additional items and statements of the staff positions on each.

These items may be included in the Open Items list of Chapter 1

in the Draft SER as sub-itemsof Section 17.5.

To be consistent with the CPGL designation of Open Items, the sub-items could be included into Open Item 220.

Please contact the Project Nanager if you have any further uestions.

Sincerely,~

Original signed by George W. Knighton

Enclosure:

As stated George H. Knighton, Chief Licensing Branch No. 3 Division of Licensing cc:

See next page 8306240467 830607 PDR ADOCK 05000400 PDR OFFICE[

SURNAME/

DATEQ DL.'.LM>~~--

NPKadambi/y

~ LI@JO ~ @JL@S 0 ~ ~ ~ ~ 0 ~ @Co ~

b/b/'d

~t ~

~

83oooo ~ ~

~

~ ~ ~ oo ~ oo ~ ~ o ~

G nichton

~0006740

~

1/0 300 ~ 0

~

~ 0 ~ 4

~ 0 ~ 0 ~ 0 ~ ~ ~ ~ ~ ~ 0 ~ IAS ~

~ 0 ~\\ ~ ~ ~ ~ ~

~ 0 ~ ~I~ ~ ~ ~ ~ ~

~

~

~

L

~ ~

~ ~ ~

NRC FORM 31S t1040) NRCM 0240 OFFICIAL R ECOR D COPY USGPO! 198l'88 980

(

'0 d

~

4

Shearon Harris M. )

E.

E. Utley Executive Vice President Power Supply and Engineering and Construction Carolina Power 5 Light Company Post Office Box 1551

Raleigh, North Carolina 27602 cc:

George F. Trowbridge,

Esq, Shaw, Pittman, Potts 5

Trowbridge 1800 l1. Street, NW Washington, D,

C.

20036 Richard E

~ Jones, Esq.

Associate General Consel Carolina Power 8 Light Company 411 Fayetteville Street Mall

Raleigh, North Carolina 27602 Yi. David Gordon, Esq.

Associate Attorney General State of North Carolina Post Office Box 629

Raleigh, North.Carolina 27602 Thomas S. Erwin, Esq.

115 W. Morgan Street

Raleigh, North Carolina 27602 Mr. George Maxwell Resident Inspector/Harris NPS c/o U.ST Nuclear Regulatory Commission Route 1, Box 315B New Hill, North Carolina 27562 Charles D.

Barham, Jr.,

Esq.

Vice President 8 Senior Counsel Carolina Power 5 Light Company Post Office Box 1551

Raleigh, North Carolina 27602 Mr. John Runkle, Executive Coordinator Conservation Council of North Carolina 307 Granville Road Chapel Hill, North Carolina 27514 Yir. Wells Eddleman 718-A Iredell Street
Durham, North Carolina 27705 Mr..George Jackson, Secretary Environmental Law Project School of Law, 064-A University of North Carolina Chapel Hill, North Carolina 27514 Dr Phyll i s Lotchin Chapel Hill, North Carolina 27514 Mr. Travis Payne, Esq.

723 W. Johnson Street Post Office Box 12643 Raleigh, North Carolina 27605 Mr, Daniel F.

Read, President CHANGE Post Office Box 524 Chapel Hill, North Carolina 27514 Bradley W. Jones, Esq.

U.S. Nuclear Regulatory Commission Region II 101 Marietta Street Atlanta, Georgia 30303 Richard D. Wilson, M.

D, 725 Hunter Street Apex, North Carolina 27502 Regional Adminstrator - Region II U.S, Nuclear Regulatory Commission 101 Marietta 'treet Suite 3100 Atlanta, Georgia 30303 Karen E. Long, Esq.

Staff Attorney Public Staff -

NCUC Post Office Box 991 Raleigh, North Carolina 27602

Shearon Harris Nuclear Power Plant.

Units 1, 2-Docket Nos.

50-400/401, Table 3.2.1-1, Page 3.2.1-5 Verify that the containment air locks, equipment hatch and valve chamber are in accordance with Section III, Article NA-5000, of the ASME Boiler and Pressure Vessel Code.

Table 3.2.1-1, Page 3.2.1-4 Verify that the containment liner is in ac'cordance with Section III, Article NA-5000, of the ASME Boiler and Pr'essure Vessel Code.

Table 3.2.1-1, Pages 3.2.1-11 through -13 Components of the letdown and makeup loop of'he chemical and

'olume control system are incorrectly classified equality Group C.

These components which are identified in the attached marked-up sheets should be classified guality Group B and the reference to note (4) deleted.

The Safety Class and component code class are acceptable'able 3.2.1-1, Page 3.2.1-11 The mixed bed demineralizer, cation bed demineralizer, and the boric acid.blender of the chemical and volume control system are incorrectly classified guality Group"D.

These components deleted should be classified guality Group C and the reference t t

(4)

The Safety Class and component code class are acceptable.

c onoe Table 3,2.1-1, Page 3.2.1-12 The guality Group classification of the boric acid batching tank of the chemical and volume control system has been omitted.

This component should be classified guality-Group D.

Table 3.2.1-1, Page 3.2.1-12'he guality Group classification of the RCP'seal bypass orifice of the chemical and volume control system is incorrectly classified guality Group C.

This component should be classified guality Group A

and the reference to note (4) deleted.

The Safety Class and component code class are acceptable.

Table 3.2.1-1, Page 3.2.1-13 The guality Group classification of the pipi'ng and values of the

~

chemical and volume control system normally or automatically isolated from parts of the system covered by a, b or c has been omitted.

These components should be classiPied guality Group D.

Table 3.2.1-1, Page 3.2.1-15 The guality Group classification of the recy'cle evaporator rea ent tank of the boron recycle system has been omitted.

This component r agen should be classified guality Group D.

4

~4P k)'H Fi l

, Table 3.2.1-1, Page 3.2.1-1?

" The Duality Group classification of the BIT recirculation

pump, boron injection surge tank, and the boron injection flush orifice of the safety injection system has been omitted.

These components should be classified guality Group C and the reference to note (4) deleted.

The Safety Class and component code class are acceptable.

Table 3.2.1-1, Page 3.2.1-18 The quality Group classification of the piping and values of the safety injection system required for supply of boric acid to BIT has been omitted.

These components should be classified

" guality Group C and the reference to note (4) deleted.

The Safety Class and component code class are acceptable.

Table 3.2.1-1, Page 3.2.1-21 The component code class of the system piping and values connected

"", to penetrations of the containment penetration pressurization

'ystem has been omitted.

These components should be classified ASME Section III, Code Class 2.

Table 3.2.1-1, Page 3.2.1-21 The guality Group classification of the WPB cooling pumps, heat exchanger (tube and shell side) and the piping and values of the waste process building cooling system has been omitted.

These components should be classified guality Group D.

Table 3.2.1-1, Page 3.2.1-23 The guality Group classification of the delay coil of the sample system is incorrectly classified quality Group D.

This component should be classified guality Group B as it is a part of the reactor coolant pressure boundary and the reference to note (4) deleted.

The e

e Safety Class and component code class are acceptable.

Identify those components in Table 3.2.1-1 to which note (8) is applicable.

5.2.1.2 In addition to Code Cases 1528 and 1355 identif ed S t en i ie sn ection of the FSAR, identify all other ASME Code Cases (including those that are listed as acceptable in Regulatory Guides 1.84 and 1.85) that were used in the construction of each Quality Group A

" components within the reactor coolant pressure boundary.

These code cases should be identified by code case number, revision, applied.

and title, for each component to which the code h

b ASHE Section III, Division 1, Subsection HD, Class 3 Components, is identified in FSAR Section 3.8 (Page 3.8.1-7) as applicable to components of the containment structure.

We find this application of Subsection HD for containment components t b

t bl a

ss of all containment components that are constructed to should be c

Class 3 of the Code.

To be acceptable containment co t

omponen s

Components.

e constructed to Subsection HC or Subsection HE Cl 2

on ass

L

~

~