Docket Nos.

50-250 June 20, l9 and 50-251 Mr. J.

W. Williams, Jr., Vice President Nuclear Energy Department Florida Power and Light Company Post Office Box 14000 Juno Beach, Florida 33408

Dear Mr. Williams:

c e 1

NR L PDR Gray File ORB¹l Rdg CParrish DMcDonald DEisenhut OELD ACRS 10 EJordan JNGrace

SUBJECT:

RELIEF REQUEST FROM TECHNICAL SPECIFICATION INSERV ICE INSPECTION REQUIREMENTS By letter dated December 16,

1983, (L-83-591) you proposed to perform a visual (VT-2) examination of the regenerative heat exchanger, in lieu of Code required volumetric and surface examinations, to provide assurance that the required level of structural integrity has been maintained.

We do not consider that a VI-2 examination alone will provide such assurance.

Therefore, we request that you submit a revised program that includes inspections in addition to, or in lieu of, the VT-2 examination.

We request that the information be provided within 60 days from receipt of this letter.

The reporting and/or recordkeeping requirements of this letter affect fewer than ten respondents; therefore, OMB clearance is not required under P.L.96-511.

Sincerely,

/s/SVarga Steven A. Varga, Chief Operating Reactors Branch ¹1 Division of Licensing cc(

See next pa' ORB¹1:

DMcDona d;ps 6/gg84 RB¹ a

6

DL 8407i20250 840620 PDR ADOCK 05000250 6

PDR

gh I\\ i H

H g

i I

1.

'I lJ i f(

" '$>!""'3 I ') AI.~~<

1

t UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, O. C. 20555 Docket Nos.

50-250 and 50-251 Mr. J.

W. Williams, Jr., Vice President Nuclear Energy Department Florida Power and Light Company Post Office Box 14000 Juno

Beach, Florida 33408

Dear Mr. Williams:

SUBJECT:

RELIEF REQUEST FROM TECHNICAL SPECIFICATION INSERV ICE INSPECTION REQUIREMENTS By letter dated December 16,

1983, (L-83-591) you proposed to perform a

visual (VT-2) examination of the regenerative heat exchanger, in lieu of Code required volumetric and surface examinations, to provide assurance that the required level of structural integrity has been maintained.

We do not consider that a VI-2 examination alone will provide such assur'ance.

Therefore, we request that you submit a revised program that includes inspections in addition to, or in lieu of, the VT-2 examination.

We request that the information be provided within 60 days from receipt of this letter.

The reporting and/or recordkeeping requirements of this letter affect fewer than ten respondents; therefore, OMB clearance is not required under P.L.96-511.

Sincerely, cc:

See next page Steven A. Varga, Chief Operating Reactors Branch 81 Division of Licensing

0 J.

W. Williams, Jr.

-Florida Power and Light Company Turkey oint Plants Units 3 and

.4 cc:

Harold F. Reis, Equire Lowenstein,

Newman, Reis and Axelrad 1025 Connecticut
Avenue, N.W.

Suite 1214 Washington, OC 20036 Bureau of Intergovernmental Relations 660 Apalachee Parkway Tallahassee, Florida 33130 Norman A. Coll, Esquire

Steel, Hector and Oavis 1400 Southeast First National Bank Building Miami, Florida 33131 Mr. Henry Yaeger, Plant Manager Turkey Point Plant Florida Power and Light Company P. 0.

Box 013100 Miami, Florida 33101 Mr. M. R. Stierheim County Manager of Metropolitan Oade County Miami, Florida 33130 Resident Inspector Turkey Point Nuclear Generating Station U.S. Nuclear Regulatory Commission Post Office Box 1207 Homestead, Florida 33030 Regional Radiation Representative EPA Region IV 345 Courtland Street, N.W.

Atlanta, GA 30308 Mr. Jack Shreve Office of the Public Counsel Room 4, Holland Building Tallahassee, Florida

.32304 Administrator Oepartment of Environmental Regulation Power Plant Siting Section State of Florida 2600 Blair Stone Road Tallahassee, Florida 32301 James P. O'Reilly Regional Administrator, Region

'-I U.S Nuclear Regulatory Commission Suite 2900 101 Marietta Street

Atlanta, GA 30303 Martin H. Hodder, Esquire 1131 N.E. 86th Street Miami, Florida 33138 Joette Lorion 7269 SW 54 Avenue Miami, Florida 33143