t UNITEDSTATES NUCLEAR REGULATORY COMMISSION
- WASHINGTON, D. C. 20555 FLORIDA POl<ER AND LIGHT COMPANY DOCKET NO. 50-250 TURKEY POINT PLANT UNIT NO.
3 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 102 License No.
DPR-31 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Florida Power and Light Company (the licensee) dated December 28, 1983, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
C.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable reouirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 3.B of Facility Operating License No.
DPR-31 is hereby amended to read as follows:
84042700b2 840413 PDR ADOCK 05000250 P
I
{8)
Technical S ecifications The Technical Specifications contained in Appendix A and B, as revised through Amendment No.1OZ
, are hereby incorporated in the license.
The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective immediately.
FOR THE NUCLEAR REGULATORY COMMISSION
Attachment:
Changes to the Technical Specifications Gate of Issuance:
April 13, 1984 Steven A. V, Chief Operating Reactors Branch dl Division of Licensing
~
gpJE REgy
'+4 po 0 +
gC
+~
~O
++**+
t UNITEDSTATES t
NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 FLORIDA POllER AND LIGHT COMPANY DOCKET NO. 50-251 TURKEY POINT PLANT UNIT NO. 4 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 96 License No.
DPR-41 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Florida Power and Light Company (the licensee) dated December 28, 1983, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the h'ealth and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety o+ the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the ComIission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 3.B of Facility Operating License No.
DPR-41 is hereby amended to read as follows:
(B)
Technical S ecifications The Technical Specifications contained in Appendix A and B, as revised through Amendment No. 96
, are hereby incorporated in the license.
The licensee shall operate the facility in accordance with the Technical Speci ficati ons.
3.
This license amendment is effective immediately.
FOR THE NUCLEAR REGULATORY COMMISSION
Attachment:
Changes to the Technical Specifications Date of Issuance:
April 13, 1984 Steven A.
r a, Chief Operating Reactors Branch 41 Division of Licensing
ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO. 102 FACILITY OPERATING LICENSE NO.
DPR-31 AMENDMENT NO.
96 FACILITY OPERATING LICENSE NO.
DPR-41 DOCKET NO. 50-250 AND 50-251 Revise Appendix A as fo11ows:
~RP Tab1e 3.5-2 Insert Pa e
Tab1e 3.5-2
TABLE3.5-2 ENGINEERED SAFETY FEATURES ACTUATION NO.
FUNCTIONALUNIT 1.
SAFETY IN3ECTION 1.1 Manual 1.2 High Containment Pressure 1.3 High Differential Pressure between any Steam Line and the Steam Line Header+
1.4 Pressurizer Low Pressure+
1.5 High Steam Flow in 2/3 Steam Lines with Low Tavg of Low Steam Line Pressure++
2.
CONTAINMENT SPRAY 2.1 High Containment Pressure and High-High Containment Pressure (coincident) 3.
AUXILIARYFEEDWATER 3.1 Low-Low Steam Generator Level 3.2 Loss of Voltage (both 0KV busses)
MIN.
OPERABLE CHANNELS 1/line in each of 2 lines 2 per set
.2 2
MIN.
DEGREE OF REDUN-DANCY 1/set OPERATOR ACTION IF CONDITIONS OF COLUMN 1 OR 2 CANNOT BE MET Cold Shutdown Cold Shutdown Cold Shutdown Cold Shutdown Cold Shutdown Cold Shutdown Hot Shutdown Cold Shutdown 3.3 Safety Injection 3.0 Trip of both Main Feedwater Pump Breakers
(
See 1 above
)
Cold Shutdown This signal may be manually bypassed, when cooling down*the reactor and RCS pressure is below 2000 psig.
This signal may be manually bypassed, when cooling down the reactor and Tavg is below 543oF.
Amendment No.102 and No.
96
y3