TURKEYPOINT PLANT UNIT NO. 3 ENGINEERING EVALUATION OF INSTRUMENTATIONS YSTEM FOR REGULATORY GUIDE 1.97, REV. 3 DATE: September 1983 l

840i310277 840126 PDR ADOCK 05000250 F ':,PDR'J

SECTION III.

IV.

V.

VI.

VII.

VIII.

TABLE OF CONTENTS DESCRIPTION Regulatory Guide 1.97, Rev. 3,Requirements Evaluation Criteria Methodology of Equipment Evaluation Type A Variable List of Parameters Parameter Listing Summary Sheets List of Systems Requiring Additions, Modifications or Analysis References Conclusions PAGE NO.

2f 3 4,5 7,8 10

SECTION I REGULATORY GUIDE 1.9V, REV. 3 REQUIREMENTS

Regulatory Guide 1.97, Rev. 3, titled "Instrumentation for Light-Water-Cooled Nuclear Power Plants to Assess Plant and Environs Conditions During and Following an Accident", divides all instrumentation used for Post Accident Monitoring into five functional types as shown below:

Type A Variables:

those variables to be monitored that provide the primary information r equired to permit the control r oom oper ator to take specific manually controlled actions for which no automatic control is provided and that are required for safety systems to accomplish their safety function for design basis accident events.

Primary information is information that is essential for the direct accomplishment of the specified safety functions; it does not include those variables that are associated with contingency actions that may also be identified in written procedures.-

Type B Variables: those variables that provide information to indicate whether plant safety functions are being accomplished.

Plant safety functions are (1) reactivity control, (2) core

cooling, (3) maintaining reactor coolant system integrity, and (4) maintaining containment integrity (including radioactive effluent control).

Type C Variables:

those variables that provide information to indicate the potential for being breached or the actual breach of the barriers to fission product releases.

The barriers are (1) fuel cladding, (2) primary coolant pressure boundary, and (3) containment.

Type D Variables:

those vari'ables that provide information to indicate the operation of individual safety systems and other systems important to safety.

These variables are to help the operator make appropriate decisions in using the individual systems important to safety in mitigating the consequences of an accident.'ype E Variables:

those variables to be monitored as required for use in determining the magnitude of the release of radioactive materials and continually assessing such releases.

Post Accident Monitoring Instrumentation is divided into three categories based on the degree of equipment qualification requirements, r edundancy, power sour ces, channel availability, quality assurance, and display and recording requirements.

In general, Category 1 provides for fullqualification, redundancy, and continuous real-time display and requires on-site (standby) power.

Category 2 provides for qualification but is less stringent in that it does not (of itself) include seismic qualification, redundancy, or continuous display and requires only a

high-reliability power source (not necessarily standby power).

Category 3 is the least stringent.

It provides for high-quality commercial grade equipment that requires only offsite power.

SECTION II EVALUATIONCRITERIA

Our review of RG 1.97, Rev. 3 requirements applicable to operating plants shows that the requirements of this guide cover the r equirements of 10 CFR 50.49 and NUREG 0737 and its subsequent clarification and generic letter 82-33.

The following is the evaluation criteria used in this report for the three different categories as defined in the Regualtory Guide 1.97, Rev. 3, Table 1.

1.

ENVIRONMENTAL UALIFICATIONCRITERIA a.

Cate or 1 Instr umentation (a).

Instrumentation located in harsh environment should comply with 10 CFR 50.49 requirements and NUREG 0588 Category 1

(IEEE-323, 1974).

(b).

Instrumentation located in mild environments do not have to be upgraded if they withstand their service location conditions under normal and emergency conditions.

b.

Cate or 2 Instrumentation (a).

For safety related instrumentation, follow the same criteria used for category 1 instrumentation.

(b).

Non-nuclear safety related instrumentation located in harsh environment has to be qualified per NUREG 0588 category 1.

(c).

Instrumentation located in mild environment should follow the same criteria used for category 1 instrumentation.

c.

'ate or 3 Instrumentation Non-nuclear safety related instrumentation has to withstand its service location conditions.

2.

SEISMIC UALIFICATIONCRITERIA Category 1 and Safety Related Category 2 instrumentation:

The equipment shall comply with IEEE-344, 1975.

(Reg.

Guide 1.100)

Category 3 and non safety related related category 2 instr umentation:

No specific provision required.

3.

REDUNDANCE Only category 1 instrumentation should be provided with redundant or diverse channels, electrically independent, and physically separated from each other, and from non-safety equipment, in accordance with Reg. Guide 1.75 "Physical independence of electric systems",

up to and including any isolation device.

Category 2

and 3

instrumentation do not require redundancy.

4.

POWER SOURCES a.

b.

~Cate or 1

Instrumentation to be supplied from 120 VAC uninterruptible power

source, or from 120 VAC Offsite Power supply, backed up by an Emergency Diesel Generator if momentary interruption of.power is acceptable.

~Cate or 2

Instrumentation to be supplied from high reliability power source which can be either from:

1.

2.

3.

4, 120 VAC uninterruptible, or 120 VAC Offsite Power backed by an Emergency Diesel Generator, or 125 VDC safety-related battery, or 125 VDC nonwafety related battery e.

~Cate or 3

No specific provisions required.

5.

UALITY ASSURANCE - Qualified equipment (category 1

and safety related category 2

should comply with the Regulatory Guides listed in Table 1 of Reg. Guide 1.97 Rev.3.

6.

DISPLAY AND RECORDING Category 1 Instrumentation should be displayed on a real-time display. The indicator may be on a'dial, digital display, CRT or strip chart recorder.

Recording of instrumentation readout should be provided for at least one redundant channeL Where dedicated strip chart recorder is not provided, recording should be updated and stored in computer memory and displayed on demand.

Category 2 Instrumentation should be displayed on an individual instrument or it may be processed for display on demand.

Signal from effluent radioactivity and area monitors should be recorded.

Category 3 Instrumentation.

(Same as Category 2).

Signal from effluent radioactivity, area and meteorology monitors should be recorded.

SECTION III METHODOLOGY OF EQUIP MENT EVALUATION

We have evaluated existing system arrangements and identified components for variables Types A thru E and their conformance to Reg.

Guide 1.97, Rev.

3 requirements applicable to existing plant.

Based on our interpretation of Reg.

Guide 1.97, Rev. 3 all Post Accident Monitoring instrumentation can be divided into three groups as shown below:

ORIGINALSAFETY RELATED INSTRUMENTATION The original, safety related instruments located in harsh environment has been or will be replaced by qualified instruments per our commitment in response to bulletin 79-01B, 10CFR 50.49 or by this report.

The instruments located in mild environment do not r equir e specific qualification until revision of the Regulatory Guide 1.89 is published.

The original safety related instrumentation generally comply with the seismic qualification program which was the basis for plant licensing.

2.

ADDED OR REPLACED SAFETY RELATED INSTRUMENTATION The added or replaced safety related instrumentaton generally comply with the requirements of 10 CFR 50.49 or the latest IEEE standards.

3.

NON SAFETY INSTRUMENTATION These instruments are high quality commercial grade equipment that require no specific qualification, however if the instrument is category 2

located in harsh environment, should be environmentally qualified.

Once the evaluation of all the instrumentation has been completed, a schedule for the implementation of the required modification to comply with the Reg.

Guide requirements has been included.

Section V of this report is the Parameter Listing Summary Sheets which includes all the plant instrumentation by tag numbers, grouped in the same order as the Reg. Guide 1.97, by type and categories.

The listing summarizes all the required information to perform the evalution and the results of the evaluation are shown on the column justification/schedule.

If this column is

blank, it means that the instrument complies with the requirements of the Reg. Guide 1.97.

The Parameter Listing Summmary Sheets provide the following information:

Item, tag number, variable description, type and category, instrument existing and requir ed r anges, Q.

A.

requirements, envir onmental and seismic qualification, redundance, power

supply, display
location, schedule for implementation or justifications.

Variable description

column, described the variable as listed in the Reg.

Guide 1.97, Rev. 3.

The tag number column, lists all the sensors, indicators, displays and recorders associated with variable described.

In the column "Display Locations, Control Room C.R.", Yes, means that the indicator is located in the control room; SAS means that the data is available in SAS.

In the Column "Display Location TSC and EOF", Yes, means that the data is available on the computer display in the TSC and EOF.

Finally, section VI, lists all systems requiring modification, additions or analysis to comply with the Regulatory requirements.

SECTION IV TYPE A VARIABLELIST OP PARAMETERS

t The type A variable list of parameters, the basis for which is given in Reg. 1.97, Rev.

3, was established.

The following Emergency Operational Procedures (EOPS) were reviewed:

a.

b.

C.

d.

Immediate Action and Diagnostics (E-1)

Loss of Reactor Coolant (E-1)

Loss of Secondary Coolant (E-2)

Steam Generator Tube Rupture (E-3)

As a result of these reviews the following parameters were designated as Type A variables:

1. 'ressurizer Pressure 2.

RCS Hot Leg Temperature 3.

RCS Cold Leg Temperature 4.

Steam Generator Level Narrow Range 5.

Refueling Water Storage Tank Level Pressurizer Pressure and RCS Hot and Cold leg temperatures were designed type A variables due to their use as inputs for calculating margin to subcooling.

The Subcooling margin will be displayed in the two channels "Inadequate Core Cooling System" (ICCS) displays in the Control Room.

Specifically the operator actions pertinent to subcooled margin concern are the following:

a) b)

Maintain the RCS hot leg temperature and pressurizer pressure

stable, using Auxiliary Feedwater, steam dump, or initiating Safety Injecton as indicated in the Emergency Operating Procedur es, when the pr essurizer pressure drops below 1723 psig or the subcooling margin drops below 30oF.

If voiding in the RCS should occur, subcooled margin,no longer exists, the operator must ensure that the R.C. pumps are shut off.

The Steam Generator Narrow Range Level is designed type A variable due to its use to determine the Auxiliary Feedwater initiation to maintain the Steam Generator Level above 15% in the narrow range span during loss of Secondary Coolant and for Steam Generator Tube Rupture Events.

The RWST Level is designed type A variable due to its use in determining the cold leg recirculation mode switchover or R.C. pump stop during Loss of Reactor Coolant Accident (LOCA).

SECTION V PARAMETER LISTING

SUMMARY

SHEETS

12/83 Sheet 1 of 2 UNIT 3 NOTES For Ta No:

(LS) ~ Limit switch associated with valve For Environmental Column:

1.

Comply with 10 CFR 50-49 and NUREG 0588 Category I.

2.

Will comply with 10 CFR 50-49 and NUREG 0588 Category I.

3.

Comply with 10 CFR 50-49 and NUREG 0588 Category II.

4.

Will comply with 10 CFR 50-49 and NUREG 0588 Category II.

5.

Original equipment environmentally qualified per 79-01B Report.

6.

Non-Safety-Related Category 2 instruments located in harsh environment'comply with 10 CFR 50-49 and NUREG 0588".

7.

Non-Safety-Related Category 2 instruments located in harsh environment 1

"will comply with 10 CFR 50-49 and NUREG 0588".

8.

Instruments located in mild environment (all categories)

"No specific qualification required".

For Seismic uglification Column:

9.

"Original Equipment":

comply with the seismic qualification program which was the basis for plant licensing.

10.

New and Re laced E ui ment:

Comply with Reg.

Guide 1.100.

ll.

New and Re laced E ui ment:

Will comply with Keg. Guide 1.100.

For Power Su 1

Column:

Power source is identified as:

12.

13.

Class lE, 120 VAC uninterruptible power supply (inverters).

Class lE, 120 VAC offsite power backed up by the Emergency Diesel Generator.

14.

Class 1E, 125 DC safety related battery.

15.

Non-Class 1E, 120 VAC offsite power (interruptible).

16.

Class 1E, 4.160 kV AC offsite power with no back up.

17.

Class 1E, 480 Volt AC offsite power with no back up.

P 18.

No electrical connection.

12/83 Sheet 2 of 2 UNIT 3 For Schedule/Justification Column 19.

Qualification Report for the ICCS will be issued by Combustion Engineering by January 31, 1984.

20.

Safety grade limit switches have been installed.

Wiring to SAS will be provided.

21.

-Deleted-.

22.

Single Channel SMM is now in operation.

The SMM will be displayed in the two-channel ICCS by January 1984.

23.

Auxiliary feedwater upgrade to be completed during next Unit 3 outage.

24.

To be replaced or added during 1985 refueling outage.

25.

A non-safety related steam generator feedwater level "Vide Range" instrument loop with readout in the main control boards also available.

26.

Category 1 redundancy does not apply because a secondary containment iso1ation valve is generally available from each line penetrating the containment.

27.

Range does not comply, however fixed area radiation monitors located at areas important to safety'will not be useful to an operator carrying a portable high range area detector on the trip to, at, or from the area important to safety.

GENERAL NOTES:

28.

Recording will be stored and displayed continually on demand in SAS.

29.

SAS Implementation Plan will be submitted by May 1, 1984.

30.

Only narrow range level indication is required.

Upon loss of narrow range level for a period of up to four (4) hours the unit should be placed in hot shutdown within seven (7) hours, and in cold shutdown within the following thirty (30) hours (Technical Specification 3.0).

PAIUNETER LI Y SHEETS UNIT 3 POINT TAG NO.

VARIASLE DESCRIPTION TYPE GORY CATE-EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE-MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN POWER DANCE SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULEI JUSTIFICATION PlhÃr SPECIFIC hl RCS PRESSURE RCS Prcssure 0-3250 PSIC Plant Speclflc Comply Note 1

Note 10 PT-406 Note 12 SAS Yes Ycs PT-406 ICCS A ICCS B

RCS Pressure Display A Display B Comply

'M Ill Comply Mill Comply Note 1

Note 2 Note 2 I

Note 10 Note 11 Note 11 ICCS B ICCS A SAS Yee Yes Yes Yes Note 19 Note 19 A2 RCS HOT LEC MTR TEMPERATURE TE-413A RCS Hot Leg Mtr. Tcep.

Loop h 0-750 P Plant Speclflc Comply Note 1

Note 10 TE 413B Note 12 SAS Yes es TE 413B TE 423A TE 423B RCS Hot Leg Mtr. Temp.

Loop h RCS Hot Leg 'Mtr. Tcep.

Loop B RCS Hot Leg Mtr. Temp.

Loop B TE 413A TE-423B TE-423A TE 433A TE-433B TR 413 ICCS A ICCS B

RCS Hot Leg 'Mtr. Temp.

Loop C RCS Hot Leg Mtr. Temp.

Loop C RCS Hot Leg Mtr. Temp.

Recorder Loop h, B, C Display A Display B

Ml1 1 Coeply Mf1 1 Coep ly Note 8 Note 2 Note 2 Note 11 Note 11 TE-433B TE-433A N/A ICCS B

ICCS A Yes Ycs Ycs Note 19 Note 19 cpo.NQN.x s ss

PARAMETER LI UMMARY SHEETS UNZP 3 TURKEY POINT 0

Sheet 2

of ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY'ATE.

EXISTING REQUIRED INSTRUMENTRANGE REOUIRE.

ENVIRONMENTAL MENT OUALIFICATION SEISMIC OUALIFICATION REDUN-DANCE POWER SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULEI JUSTIFICATION FIANT SPECIFIC (Continued)

TE-410A TE-4108 TEA20A TE-4208 TE-430A TE-4308 TR-410 ICCS h ICCS B RCS COLD IZC UTR TEMPERATURE RCS Cold Leg Ntr. Teap.

Loop h RCS Cold Leg Utr. Teap.

Loop h RCS Cold Leg Ntr. Tcap.

Loop 8 RCS Cold Leg Qtr. Teap.

Loop B RCS Cold Leg Ntr. Teap.

Loop C RCS Cold Lcg Qtr. Tcap.

Loop C RCS Cold Leg Ntr. Teap.

Recorder Loop h, B, C Display A Display 8 I

0 150 P

Plant Specific Coaply Coaply Hill Coaply NIII Coaply Note I Note 8 Note 2 Note 2

Note 10 Hots 10 Note 11 Note 11 TE 410B TE 410A TE 4208 TE-420A TE-430B TE 4304 NIA ICCS B ICCS A Note 12 SAS Yes Yes Ycs Yes Yes Note 19 Note 19 RUST LEVEL IT-6583A RUST Ch. A Level LI-6583A RUST Ch. A Level Ind.

LT-6583B RÃST Ch.

B Level LI-6583B RUST Ch.

B Level Ind I

0 330>000 Cal ~

0-330,000 Cal.

0 330,000 Cal.

0 330,000 Cal.

Plant Specific V

Hill Ccaply Note 2 Note 8 Note 2 Note 8 Note 11 LT 6583B LI-65838 LT-6583A LI-6583A Yes Yes Yes Yes Note 24 Note 24 Yes Yes Note 24 Note 24 ceo

'Jx>oo

>> s;ss

PARANETER LISTI UNIT 3 Y SHEETS QINP Sheet 3

of 46 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE CATE GORY EXISTING REQUIRED INSTRUMENTRANGE ENVIRONMENTAL MENT QUALIFICATION SEISMIC QUALIFICATION REDUN.

POWER DANCE SUPPLY DISPLAY LOCATION TSC EOF SCHEDULE/

JUSTIFICATION LT 474 LI-474 LT-475 LI 475 LT-416 Ll-416 Ut-478 LT-484 LI-484 LT-485 LI 485 LT-486 LI-486 LR-488 PIANt'PECIPIC (Conttnucd)

S.C.

LEVEL NARRtrt RANCE S.C. 'A'vl. Ch. I Narrow Range S.C. 'A'vl~ Ch. I Narrov Range Ind.

S.C. 'A'vl. Ch. II Narrow Range S.C. 'A'vl. Ch. II Narrow Range Ind.

S.C. 'A'vl. Ch. III Narrov Range S.C. 'A'vl. Ch. III Narrov Range Ind.

S.C. 'A'vl. Ch. I, II, 111 Narrow Range Recorder S.C. '8'vl. Ch. I Narrov Range S.C. '8'vl. Ch. I Narrov Range Ind.

S.C. '8'vl. Ch. II Narrov Range S.C. 'B'vl. Ch. II Narrow Range Ind.

S.C. 'B'vl. Ch.

111 Narrow Range S.C. '8'vl. Ch.

111 Narrow Range Ind.

S.C. '8'vl. Ch. I, II, III Narrov Range Recorder 30.1" to 138.22" Plant Spectflc 0 - IOOE 30.1" to 138.22" 0 - 1001 30.1" to 138.22"

- Ietyt 1002 30.10 to 138.22" 0 - 1002 30 1" to 138.22"

- IOOE 30 1" to 138.22"

) - 1002

) - 1002 Comply Note I Note 8 Note I Note 8 Note I Note 8 Rotc 8 Note 1

Note 8 Note 1

Note 8 Note I Note 8 Note 8 Note 10 Note 9 Note 10 Note 9 Note 10 Note 10 Note 10 Note 10 Note 9 Note 10 Note 9 Note 10 Note 10 Note 10 LT 475 LT-476 LI-475 LI-476 LT-474 LT-476 LI-474 LI-476 LT-474 LT 475 LI-414 LI-475 N/A LT-485 LT-486 LI-485 LI-486 LT-484 LT-486 LI-484 LI-486 LT-484 LT-485

- Ll-484 LI-485 N/A Note 12 Ycs Yes SAS Ycs Ycs Ycs Ycs cs Ycs Ycs Ycs Yes Yes Yes Yes Yes Yes Yes Ycs cto %000 ~ X 9/sl

PARAHETER LI HNIT 3 1 Y SHEETS POINT S)u 4

Ot 46 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY CATE.

EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE-

'ENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

POWER DANCE SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULEI JUSTIFICATION LT-494 LI-494 LT-495 LI-495 LT-496 LI-496 LR 498 S.C.

LEVEr. NARRal RANCE (Con tInoe d)

S 0 AC> Lvl. Ch. I Narrov Range S.C. 'C'vl. Ch. I Narrov Range Ind.

S.C. 'O'vl. Ch.

11 Narrov Range S.C. 'O'vl. Ch. II Narrov Range Ind.

S,C. 'C'vl. Ch. III Narrou Range S.C. 'C'vl. Ch. III Narrov Range Ind.

S.C. 'C'vl. Ch. I, II, III Narrov Range Recorder 30.1" to 138.22" 0 - 1002, 30.1" to 138.22" 0

1001, 30 I" to 138.22" 0 - ICOS 0 - 1001 Plant Specific Cooply Note I Note 8 Note I Note 8 Note I Note 8 Note 8 Note 10 Note 9 Note 10 Note 9 Note 10 Note 10 Note 10 LT 495 LT-496 LI-495 LI-496 LT-494 LT-496 L1-494 LI-496 LT-494 LT-495 LI-494 Ll-495 N/A Rotc 12 SAS Ycs Yes Yes SAS Ycs Yes Yes SAS Yes Yes Yes Yes GPD @000 ~ a 9 N

PARAHKIKR LIST Y SHEEtS UNIT 3 TURKEY POINt Sheet 5

of~a ITEM 81 TAG NO.

VARIABLE DESCRIPTION RKACFIVITY CONTROL - NEUTRON F UlX TYPE CATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE-MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION TSC EOF SCHEDULE/

JUSTIFICATION N 35 NI-35-B N-36 NI 36-B Neutron Flux (Interaedtate Range)

Neutron Flux (Interaedtate Range) Indtcator Neutron Flux (Interaedfate Range)

Neutron Plux (Interaedtate Range) Indicator 10 to 10 AHP 10 to 100K Full Fever ttI 1 1 Coop ly Note 2 Note 8 Note 2 Note 8 Note ll N-36 NI-368 N-35 NI 35B Note 12 SAS Yes.

SAS Yes Yes Yes Yes Yes Note 24 Note 24 Note 24 Note 24 82 70CR 71CR 72CR 73CR RFACTIVITY CONFROL CONTROL ROD POSITION Control Rod Bank

'h'od Bottoa Suttch Control Rod Bank

'8'od Bottoa Suftch Control Rod Bank

'C'od Bottoa Svltch Control Rod Bank

'D'od Bottoa Sultch Control Rod Bank

'h'od Bottoa Sultch Full In Or Not Full Io Full In Or Not Full In NIA N/A N/A N/A Note 14 SAS Yes Yes 75CR Control Rod Bank

'B'od Bottoa Snitch RFACFIVITY CONTROL - RCS SOLUBLE BORON CONCKNfRATION AK-6424 Boron hnalyter RCS Soluble Boron Concentration 0-6000 PPH 0-6000 PPH NIA N/h N/A NIA Note 15 SAS Yes Yes Gto sxxu x i es

PARAMETER LI Y SHEETS VNIT 3 TD POINT She 6 pf~

ITEM TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION RE DUN-POWER DANCE SUPPLY DISPLAY LOCATION TSC EOF SCHEDULE/

JUSTIFICATION TE-410A TE 410B TE-420A TE-420B TE-4304 TE 430B TR-410 ICCS h 1CCS B

REACTIVITY CONTROL RCS COLD LEC MTR. TEMP.

RCS Cold Leg Wtr. Temp.

Loop

'A'CS Cold Leg Wtr. Teap.

Loop

'h'CS Cold Leg Mtr. Temp.

Loop

'B'CS Cold Leg Mtr. Temp.

Loop sB ~

RCS CoLd Leg 'Mtr. Temp.

Loop

'C'CS Cold Leg 'Mtr. Teap.

Loop

'C'CS Cold Leg Mtr. Temp.

Recorder Loop A, B, C Display she Display 'B'

- 750 P 50 - 400 r SEE ITEM A3 B5 TE-413A TE.413B TE-423A TE-423B coRE cooLINc - Rcs Hot LEc MTR. TEMP.

RCS Hot Leg Mtr. Temp.

Loop

'A'CS Hot Leg Mtr. Temp.

Loop

'h'CS Hot Leg Wtr. Teap.

Loop

'B'CS Hot Leg Wtr. Temp.

Loop 'B'

- 750 j 50 700 P SEE ITEM A2 ciao aaam a e ea

P~R LI IJHIT 3 Y SHEETS poly She 7

of ~~

85 TAG NO.

VARIABLE DESCRIPTION CORE COOLINC - RCS HOI'EC lftR. TEIIP.

(C

~ t d)

ATE-ORY TYPE G INSTRUMENTRANGE EXISTING

~

REQUIRED Q.A.

REQUIRE.

MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN POWER DANCE SUPPLY DISPLAY LOCATION CR EOF TSC SCHEDULEI JUSTIFICATION TE-433A TE-4338 TR-413 ICCS A ICCS 8 RCS Hot Leg 'Mtr. Temp.

Loop

'C'CS Hot Leg Mtr. Temp.

Loop 'C' Recorder Loop h, 8, C

Display

'A'tsplay'8'

I 0 - 750 P 50 - 700 P

SEE ITEM A2 86 TE-410A TE 4108 TE 420A TE-4208 TE-430A TE 4308 TR 410 ICCS A ICCS 8 CORE CODLING RCS COLD IZC WTR. TEMP.

RCS Cold Leg Htr. Temp.

Loop

'h'CS Cold Leg Mtr. Temp.

Loop

'A'CS Cold Leg Mtr. Temp.

Loop

'8'CS Cold Leg IItr. Temp.

Loop

'8'CS Cold Leg Mtr'. Temp.

Loop

'C'CS Cold Leg Mtr. Temp.

Loop sos Recorder Loop h, 8, C

Display

'h'isplay'8' 750 P 50 - 700 P

SEE ITEM A3 cto lxmo x s ss

PARAMETER LI UNIT 3 TU Y SHEETS POINT Sh S

o(~4 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE ATE.

GORY EXISTING REQUIRED INSTRUMFNTRANGE Q.A.

REQUIRE-MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN POWER DANCE SUPPLY DISPLAY LOCATION TSC EOF CR SCHEDULE/

JUSTIFICATION B7 CORE COOLINC RCS PRESSURE RCS Prcssure 0

3230 PSIC 0 - 3000 PSIC SEE ITKH Al PT 406 RCS Pressure ICCS h ICOS B Display

'A'isplaysB BS TE-IE Thru TE-SIE ICCS A ICCS B CORE COOLIHC CORE EXIT TEHP.

Core Exit Teoperature Display

'A'isplay'B'00

- 2300 F 200 - 2300 F N/A N/A N/A N/A N/A N/A Note 12 Note 12 Hots 12 Yes Yes Yes Yes B9 ICCS RVL-A, (HJTC)

ICCS RVL B (IUTC)

ICCS A ICCS B CORE COOLINC COOIAHT IHVKÃIORY Reactor Vessel Mtr. Lvl.

Ch

>As Reactor Vessel Mtr. Lvl.

Ch

'B'isplay shs Display

'B Top of Core to Top of Vessel Bottom of Hot Leg to Top of Vessel Mill Coop ly Note 2

Note 11 RVL-B RVL-h ICCS B

ICOS A Note 12 SAS Yes Yes Ycs Yes Note 19 Yes

'Tes Note 19 Note 19 Note 19

'ciao'sxKxl ~ x s eJ

PARAHETER LIS UNIT 3 T Y SHEETS POINI' 9

OI~

ITEM TAG NO.

VARIABLE DESCRIPTION ATE.

ORY TYPE G EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE-MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULEI JUSTIFICATION BIO SHT-A SMf B, CORE COOLINC DECREES OF SUBCOOLINC RCS Temp. Saturation Margin Ch.

'A'CS Temp. Saturation Hargtn Ch.'8'100 co 700 F 200 F Subcoollng to 35 F Super-Caay ly Comply Note I Not'c I Note 10 Note 10 SHT-8 SHT-h Note 12 ICCS Yes SAS Note 12 ICCS Yes SAS Yes Ycs Note 22 Note 22 811 MAINfAININCRx COOIAÃf SYS.

INTECRIIY RCS PRESSURE RCS Pressure 0 - 3250 PSIC 0 - 3000 PSIC SEE ITEM Al Ff-406 RCS Prcssure ICOS A ICSS B

Display

'A'tsplay

'8'12 MABffAININCRx COOIANI'YS.

INTECRITY CIMf SUMP MIR.LVL.

LT-6308A Ctmt.

Sump Mtr. Lvl.

LI-6308A Ctmt.

Sump Mcr. Lvl. Ind.

LR-6308A Ctmt.

Sump Mtr. Lvl.

LT-63088 Ctmt.

Sump Mtr. Lvl.

LI-63088 Ctmc.

Sump Mcr. Lvl. Ind.

LR-6308B Ctmt.

Sump 'Mtr. Lvl.

lgept El. co El. 14'-0" 0 - 369" 0 - 369eI

-18'Pt. El. co El 14'-0" 0 - 369" 0

369" Nsrrou Range (S~)

Comply Note I Note 8

Note 8 Rote I Note 8 Note 8 Note 10 LT-63088 LI-63088 LR-63088 LT-6308A LI 63088 UI-63088 Note 12 SAS Yes Yes Yes SAS Yes Ycs Yes Yce Ycs GpD Sxxo ~ x ass

PARAHETER Ll Y SHEETS UNIT 3 TU Y POINf 10 Of 46 ITEM 813 TAG NO VARIABLE DESCRIPTION HAIIffAININCRx COOIANf SYS INfECRIIY CTNf. SUMP VIR.LVL.

GORY CATE.

INSTRUMENTRANGE EXISTING

'EQUIRED ENVIRONMENTAL SEISMIC MENT QUALIFICATION QUALI ICATI N REDUN.

DANCE POWER SUPPLY TSC EOF DISPLAY LOCATION SCHEDULE/

JUSTIFICATION LT-6309A Ctnt. Mtr. Lvl.

B El. 14'-0" to Ei. 22'-0" Mfde Range lant Spccfffc)

Coop ly Note I Note 10

'T-63098 Note 12 SAS Ycs Yce LI-6309A Ctnr.. Mtr. Lvl. Ind.

LR-6309A Ctnt. Mtr. I.vl.

LT 63098 Ctnt. Mtr. Lvl.

397" to 487" 397" to 487" El. 14'-0" to El. 22'-0" Note 8 Mote 8 Note 1

LI-63098 LR-63098 LT-6309A Yes Yes Yes LI-63098 Ctnt. Mtr. Lvl. Ind.

IR-63098 Ctnt. Mtr. Lvl.

397" to 487" 397" to 487" Note 8 Nots 8 LI-6309A LR 6309A Ycs Yes 814 HAIHfAIHINCRx COOIANI'YS.

INfECRITY-CfÃfPRESSURE PT-6306A CIHI. Press.

Mfde Range PI-6306A Ctnt. Prese.

Mfde Range lnd.

PR-6306A Ctnt. Press.

Mfde Range PT-63068 Ctnt. Press.

Mfdc Range PI-63068 Ctnt. Press.

Hide Range Ind.

PR-63068 Ctnt. Prese.

Mfde Range 0 - 180 PSIO 0 PSIC to Desfgn Pressure Coop ly Note I Note 8 Note 8 Note I Note 8 Note 8 Note 10 PT 6306B PI-6306B PR-6306B PT-6306A PI-6306A PR-6306A Note 12 SAS Yes Yce Yes Yes Yes Yes Yes Yes 815 HAINf*IHINOCfHf. INfECRITY CTHf. ISOLATION VALVE POSITI HOV 744A RHR to Cold Leg I.C.

HS 744A Mfth Ind. Lfghts HOV-7448 RHR to Cold Leg I.C.

HS 744B Mfth lnd. Lfghts Open Closed Closed Not Closed Coop ly Note 5

Note 8 Note 5 Note 8 Note 9

N/A N/A N/A N/A Note 13 SAS Ycs Ycs Yes Yes Yes Note 26 Ycs Note 26 CtD 4XXO.x 9 44

PARAMETER LI SIfEETS UNIT 3 TURKEY POINT ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY ATE.

INSTRUMENTRANGE EXISTING REQUIRED ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

POVVER DANCE SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULEI JUSTIFICATION MOV-716A RCP Thernal Barrfer CCW Open Closed Closed Not Closed Coop ly Note 8 Note 9 N/A Note 13 SAS Yei Yes Note 26 HS-716A NV-716B HS-7168 NV-626 HS-626 HOV-730 HS-730 CV-739 (LS)

HS-739 NV-1417 HS-141 7 NV-1418 HS 1418 CV-200A (LS)

HS-2004 CV 200B (LS)

HS-200B CV-2000 (LS)

HS 200C Wfth Ind. Lights RCP Thet>sal Bartfcr CCW With Ind. Lights RCP A, B, C Thats>al Barrier Coolfng Wtr.

With Ind. Lights CCW Ero>s RCP A> B, C

Cooler Beerfng With Ind. Lights Excess Letdovn Heat Exchanger With Ind. Lights CCW to Homal CINI. Cooling With Ind. Lights CCW Iros> Honsal Cte>t. Cooli With Ind. Lights Lctdovn Line Wfth Ind. Lights Letdovn Line With Ind. Lights Letdovn Line With Ind. Lights Note 5 Note 8 Note 5

Note 8 Note I Note 8 Note 1

Note 8 Note 1 Note 8 Note 10 Note 9 Note 10 Note 9 Note 10 Note 9 Yes SAS Yes Yes SAS Yes Yes SAS Ycs Yes Note 14 SAS Yes Note 14 Note 13 SAS Yes Yes SAS Yes Yes Note 14 SAS Yes Yes SAS Yes Yes SAS Ycs Yes Yes Ycs Yes Ycs Yes Yes Ycs Yes Ycs Note 26 Note 26 Note 26 Note 26 Note 26 Note 26 c>o l300o ~ x est

0

PARAHETER LI UNIT 3 RY SHEETS POINI' 12 PI 46 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY CATE.

EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN.

POWER DANCE SUPPLY DISPLAY LOCATION SCHEDULEI JUSTIFICATION CR TSC EOF CV-204 (LS)

HS-204 NOV-381 BS-381 CV-4658A (LS)

BS-4658A CV-46588 (LS)

BS-46588 CV-46684 (LS)

BS-4668A CV 46688 (LS)

HS 46688 CV-4659A (LS)

HS-4659A CV-46598 (LS)

BS-46598 HOV 866A HS-866A BOV-8668 BS 8668 Letdovn Line Lov Press.

With Iad. Lfghts RCP Seal 'Mtr. Return Vlv.

Mich Iad. Lights RCDT Vent Vlv.

Mich Ind. Lights RCDT Vent Vlv.

With Ind. Lights RCDI'fsch. to Hold Up Tank With Ind. Lights RCDT Dfsch.

Co Hold-Up Tank

'Mfth Ind. Lights RCDT Line to H2 baal.

With Iad. Lights-RCUI'ine to H2 Anal.

Mfth Iad. Lfghts Bf Head Safccy in]. Line Mfrh Ind. Lights Hf Head Safety In]. Line Mfth lnd. Lights Open Closed Closed Not Closed C

ly Mill Coop ly Coop ly Will Coop ly Coaply Will Conply Coop ly

'Mill Coop ly Mill Coop ly Coaply Mill Cooply Coop ly Note 8 Note 2 Note 8 Note 2

Note 8 Note 2 Note 8

Note 2 Voce 8 Noec 2 Note 8 Note 2 Note 8 Note I Note 8

Note 1 Note 8 Note 9 Note 11 Note 10 Note 11 Note 10 Noes 11 Noes 10 Note 11 Note 10 Note 11 Note 10 Note 11 Note 10 Note 10 Noce 9 Note 10 Note 9 NIA Note 14 SAS Yes Note 14 Ycs Note 13 SAS Ycs Note 13 Yes Note 14 SAS Yes Yes SAS Ycs Yes SAS Yes Ycs SAS Yes Ycs Yes SAS Ycs Note 13 SAS Yes Yes SAS Yes Yes Yes Yes Yes Ycs Yes Yes Ycs Ycs Note 26 Note 26 Noes 24 Note 24 Note 24 Note 24 Note 24 Note 24 tea sxoo ~ a 9 as

PARAHETER LI Y SHEETS UNIT 3 TDIUCEY POINT ITEM TAG NO VARIABLE DESCRIPTION TYPE CATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION TSC EOF CR SCHEDULE/

JUSTIFICATION NOV 869 Hf Head Safety In). Line Open Closed Closed Not Closed Comply Note 5 Note 9 N/h Note 13 Ycs Yes HS-869 NOV-880A With Ind. Lfghts Ctmt. Spray Pump A Disch.

Vlv.

Note 8 Note'5 Ycs SAS Ycs Yes NOV-880B Ctmt. Spray Pump 8 Dfsch.

Vlv.

HS-8808 Mich Ind. Lighcs HS-880A With Ind. Lights Note 8 Note 5 Note 8 Yes Yes Ycs Ycs CV 956A (LS)

PRZR Stm.

Space Sample Note 14 Ycs Ycs HS-956A With lnd. Lights Yes CV-956B (LS)

PRZR Liquid Space Sample Ycs Yes HS-9568 With lnd. Lights SV 6427A Hot Leg RCS Sasple HS-6427h Mfth Ind. Lights SV-6427B Hot Lcg RCS Sample HS 6427B With Ind. Ltghts SV-6428 Hot Leg RCS SampIe HS-6428 With Ind. Lights SV-2912 Cent. Air Sample HS-2912

'Mfth>>lnd. Lights SV-2911 Ctmt. Afr Saopte HS 2911

'Mlth Ind. Lights SV 2913 Cent. Air Sample HS-2913 Mfth lnd. Lights Hots 1

Note 8 Note I Note 8 Note I Note 8 Note 1

Note 8 Note 1

Note 8 Note 1

Note 8 Note 10 Note 10 Note 9 Note 10 Note 9 Note 10 Note 9 Note 12 Ycs SAS Ycs Ycs Yes

,Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Ycs Ycs Yes oto uoao.x s ss

PARAMETER LIS RY SHEETS IJNIT 3 POINI'4 pf 46 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY CATE.

EXISTING REQUIRED INSTRUMENTRANGE REQUIRE ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN-POWER DANCE SUPPLY DISPLAY LOCATION TSC EOF SCHEDULE/

JUSTIFICATION CV 519A (LS)

PRZR RelfeE Tnk. Deafn. 'Mtr.

Open Closed Closed Not Closed Coeply Note 8 Note 9 N/A Note 14 SAS Yes Yes HS-319A Mfth Ind. Lights POV 2600 (LS)

Ctnt. Purge HS 2600 Mlth Ind. Lights POV 2601 (LS)

Ctat.

Purge HS 2601 IIlth lnd. Lights POV-2602 (LS)

Ctnt. Purge HS-2602 Mlth Ind. Lfghts POV 2603 (LS)

Ctat. Purge HS-2603 Mlth lnd. Lights POV-2604 (LS)

Msfn Sta.

HSIV S.C.

'A'S-2604 Mlth Ind. Lights MOV-1400 Msfn St@. Line

'A'S-1400 Mfth lnd. Lights MOV-1403 Mala Stn. Line

'A'S-1403 Mlth lnd. Lights POV 2605 (LS)

HS-260$

Msfn Sta.

MSIV S.C.

'B'lth Ind. Lights MOV-1404 Msfn Stn. Line

'B'S-1404 Mlth lnd.. Lights MOV-1401 Mein Stra. Line 'Bs HS-1401 Mlth Ind. Lights Note 8 Note 8

Note 8 Note I Note 8 Note 8 Note 8 Note I Note 8 Note I Note 8 Note 8 Note 8 Note I Note 8

~

Note I Note 8 Note 5 Note 8 Note 8 Note 8 Note 9

Note 9 Note 9 Note 10 Note 9 Note 9 Note 9 Note 10 Note 9 Note 10 Note 9 Note 9 Note 9 Note 10 Note 9 Note 10 Note 9 Note 9 Note 9 Note 9 Note 9 Note 13 Note 14 Note 14 Note 13 Ycs Ycs Yes Ycs Yes Yes Yes Ycs Yes Ycs Yes Yes Yes Yes Yes Yes Yes Ycs Ycs Yes Ycs Yes Ycs Yes Yes Yes Yes Yes Yes Yes GIo.sxxu x s el

PARAHEIER LI UIVIARY SHEEIS UNIT 3 TURKEY POINT TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

ORY

EXISTING, REQUIRED INSTRUMENTRANGE REQUIRE ENVIRONMENTAL Q.A.

MENT QUALIFICATION SEISMIC QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION TSC EOF CR SCHEDULEI JUSTIFICATION POV-2606 (LS)

HS-2606 HOV-1405 HS-1405 HOV-1402 HS-1402 FCV-478 FCV-479 PCV-488 Hafn Stm. HSIV S.C.

'C'ith Ind. Lights Hain Stn. Line

'C'fth Ind. Lights Hain Stn. Lfne

'C'ith Ind. Lights S.C. 'h'ecdvater No Indication S.C. 'h'eedvater No Indicatfon S.C. '8'eedvater No Indication Open Closed Closed Not Closed Coup ly Will Coap ly Note I Note 8 Note 1 Note 8 Note 8 Note 8 Note 2 Note 10 Note 9 Note 10 Note 9 Note 9 Note 9 Note 11 NIA Yes Rotc 14 Yes Note 14 SAS Note 14 Ycs Note 13 Yes Yes Yes Yes Ycs Yes Yes Yes Yes Yes Note 24 Ycs Yes FCV-489 FCV-498 FCV-499 S.C. '8'eedvater No Indication S.C. 'C'eedvater No Indfcatfon S.C. 'O'eedvater No Indication SAS SAS Yes Yes Yes Yes Ycs Yes CV 2816 (LS)

HIC-1401A CV-2831 (LS) hux. Fecdvater to S.C.

'h'and Indicating Controller hux. Feedvatez'o S.C.'A'oup ly Note I Note 8 Note 1

Not'e 10 Note 9 Note 10 Ycs Note 12 Yes Note 14 SAS Yes Note 20 Note 20 HIC-14018 CV-2817 (LS)

HIC-1457h Hand Indicating Controller hux. Feedvatcr to S.C.

'8'and Indicating Controller Note 8 Note I Note 8 Note 9 Note 10 Note 9 Note 12 Yes Note 14 SAS Note 12 Yes Yes Yes Note 20 ceo moo x ass

PARAMETER LI Y SHEETS UNIT 3 T Y POINT 16 OI 46 ITEM TAG NO.

VAR I A()LE DESCRIPTION TYPE GORY CATE.

EXISTING REQUIRED INSTRUMENTRANGE ENVIRON ENTA SE SM C MfNT QUALIFICATION OUALIFICATION REDUN-DANCE POWER SUPPLY DISPLAY LOCATION TSC EOF SCHEDULE/

JUSTIFICATION CV-2832 (LS)

Aux. Peedvater to S.C. 'B'pen Closed Closed Not Closed Comply Note 1

Note 10 N/A Note 14 SAS Yes Yes Note 20 HIC-14578 Hand Indi cating Controller CV-2818 (LS) hux. Peedvater to S.C.

'C'IC-1458A Hand Indlcatlng Controller CV-2833 (LS)

Aux. Pcedvacer to S.C.

'C'V-6275A (LS)

S.C.

>As Blovdovn HS-6275A Mich Ind. Llghcs CV 6275B (LS)

HS-62758 CV-6275C (LS)

S.C. 'B'lovdovn Mlth Ind. Lights S.C.

~ Ce Blovdown HS-6275C Mlth 2nd. Lights HOV-1427 S.C. 'A'lovdovn Sample HS 1427 Mith Ind. Lights HOV-1426 S.C. '8'lovdovn Sample HS-1426 Mlth Ind. Lights HOV-1425 S.C. 'C'lovdovn Sample HS-1425 'lth Ind. Llghcs CV 2903 (LS)

HS 2903 CV 2904 (LS)

CCM to Emergency Ctmt.

Cooler 8 Mich Ind. Lights CCM to Emergency Cent Cooler C

HIC-14588 Hand indlcatlng Controller Mill Comp ly Comp ly MIII Comply Mote 8 Note 1

Note 8 Note 1

Note 8 Note 1

Note 8 Note I Note 8 Note 1

Note 8 Note 5 Note 8 Note 5 Note 8 Note 5 Note 8 Note 2 Note 8 Note 2

/

Note 9 Note 10 Note 9 Note 10 Note 9 Note 10 Note 9 Note 11 Note 9 Note 11 Note 12 Note 14 Note 12 Note 14 Note 12 Note 14 Note 13 Ycs Yes Yes Yes Yes Yes Ycs Yes Yes Yes Yes Note 20 Yes Yes Note 20 Ycs Yes Yes Yes Yes Yes Ycs Yes Yes Yes Yes Yes Yes Yes Note 24 Yes Yes Note 24 HS 2904 Mlth Ind. Lights Comply Note 8 Note 9 Ycs cto Nvoo ~ x s N

PARANEIER I.I SHEETS UNIT 3 T OINI 17 OI 46 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY ATE.

EXISTING

~

REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN.

POWER DANCE SUPPLY DISPLAY LOCATION EOF CR TSC SCHEDULEI JUSTIFICATION Note 13 SAS Yes Note 24 CV-2905 (LS)

HS-2905 CV-2810 (LS)

HS-2810 CV-2906 (LS)

HS-2906 CV-2812 (LS)

HS 2812 CV-2907 (LS)

HS-2907 CV-2814 (LS)

HS-2814 CV 2908 (LS)

S-2908

-872 IIS-872 p-)55 S-855 CV-956D (LS)

HS 956D CGI to Eaergency Ctat.

Cooler h Mith Ind. Lights CCM froa Eaergency Ctat.

Cooler B Mith Ind. Lights CCM fraa Eaergency'Ctat.

Cooler B Mfth Ind. Lights CCM froa Eaergency Ctat.

Cooler C Mith Ind. I.fghts CCM froa Eaergcncy Ctat.

Cooler C

Mfth Ind. Lights CCM froa Eaergency Ctat.

Cooler A Mith Ind. Lights CCM froa Eacrgcncy Ctat.

Cooler A Mfth Ind. Lights Lou Need Safety In]cct.

Mith Ind. Lights N2 Supply to Accuaulstors Mith Ind. Lights Accuaulctor Sasple Line

'Mith Ind. Lights f

7 Open Closed Closed Not Closed Mill Coeply Cocply Mill Caeply Coop ly Mill Caeply Coop ly Mill Caeply Coop ly Mill Caeply Coeply Mill Caaply Caeply Mf11 Coeply Coop ly Note 2 Note 8 Note 2 Note 8 Note 2 Nate 8 Note 2 Note 8 Note 2 Note 8 Note 2

~ Note 8 Note 2 Note 8 Note 5 Note 8 Note ll Note 9 Note 11 Matc 9 Note ll Note 9 Note ll Note 9 Note ll Note 9

Note ll Note 9 Note 11 Note 9 NIA Rotc 14 Yes SAS Yes Ycs SAS Yes Yes SAS Yes Yes SAS Yes Ycs SAS Yes Yes SAS Yes Ycs SAS Yes Ycs Ycs SAS Yes Yes Yes Yes Yes Ycs Yes Yes Yes Yes Note 24 Note 24 Note 24 Note 24 Note 24 Note 24

,PARAMEIER LI UNIT 3 Y SHEETS Y POINT S

OI 18 of~4 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY CATE.

EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN POWER DANCE SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULE/

JUSTIFICATION MOV 843A'S-843A Boron Iaj. Tank Out Stop Valve Mith Ind; Lights HS-843B CV-2821 (LS)

Mith Iad. Lights Ctet. S~ Disch.

MDV-8438 Boron In). Tk. Out Stop Vlv.

Open Closed Closed Not Closed Note 5 Note 8 Note 5

Note 8 Nocc 8 Note 9 Note 9 Note 9 Note 9 Nocc 9 N/A Note 13 SAS Yes Noes 14 SAS Ycs Yes Yes Yes Yes HS-2821 CV-28ZZ (LS)

HS-2822 CV-2819 (LS)

CV 2826 (LS)

Mith lnd. Lights Ctet.

Suep Disch.

Mith Ind. Lights Inst. Air Bleed Inst. Air Bleed Note 1 Note 8 Note 10 Note 9 Yes Ycs Yes Yes Yes Ycs Yes Yes CV-516 (LS)

HS-516 SV-6385 S-6385 Cas Analyser Saeple Vlv.

Mith Ind. Lights Cas Analycer Saeple Vlv.

'Mith Indicat lag Lights MOV-6386 RCP Seal HS-6386 Mith Ind. Lights Note I Note 8 Note 10 Note 10 Note 9 Note 9 Note 9 Note 10 Yes Ycs Yes Yes Yes Yes Yes Yes 816 MAIÃlAININCCOÃIAI MMES IMIECRITY CONTAINMENT PRESSURE PT-6306A Ctet. Mide Range Presa.

PI-6306A Ctet. Mide Range Press.

Ind.

PR-6306A Ctet. Mide Range Press.

0 - 180 PSIC

-5 PSIC to Design Pressure SEE ITEN B14 Gpo.ssxa.x slsl

PARAMEIER LI Y SNEETS UNIT 3 POINT ITEM TAG NO.

VARIABLE OESCRIPTION ATE.

ORY TYPE G EXISTING REQUIREO INSTRUMENTRANGE ENVIRONMENTAL SEISMIC REQUIRE-QUALIFICATION QUALIFICATION MENT REDUN.

OANCE POWER SUPPLY CR TSC EOF OISPLAY LOCATION SCHEOULEI JUSTIFICATION PT 6306B PI-6306B PR-6306B PT-6425A PI-642 5A PR-6306h PT 6425B PI-6425B PR 6306B MAINTAININCCONIAINMEÃf INIECRITY CONTAINMENr PRESSURE (Continued)

Ctnt. Nfdc Range Press.

Ctnt. Nfde Range Press.

Ind.

Ctfat. Nfde Range Press.

Ctett. Narrow Range Press.

Ctnt. Narrow Range Press.

Ind Ctnt. Narrow Range Press.

Ctatt. Narrow Range Press.

Ctot. Narrow Range Press.

Ind.

Ctnt. Narrow Range Press.

B I

0 - 180 PSIC

-6 to +18 PSIC

-5 PSIC to Desfgn Pressure

-5 PSIC to Des1gn Pressure Cocply SEE ITEN B14 Note I Note 8 Note 8 Note 1

Note 8 Note 8 Note 10 PT-64258 PI 6425B PR 63068 Pf-6425A PI 6425h PR-6306A Note 12 SAS Yes SAS Yes Ycs Yes Yes es oto-Koan.x Ass

PARAHEIER L UNIT 3 UHNARY SHEETS POINP Ot 4<

ITEM TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

GORY INSTRUMENTRANGE EXISTING REQUIRED Q.A.

REQUIRE-MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN-DANCE POWER SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULE/

JUSTIFICATION Cl TE-IE Thru TE 51E ICCS A ICCS B FUEL CIADDINC CORE EXIT TEHPERATURE Coze Exit Teoperature Display

'A'isplay sBs 200 F - 2300 F 200 F - 2300 F NIII Coop ly Note 2 Note 11 2 Channel Per Quadrant ICOS B ICCS A Note 12 SAS Yes Yes Yes Yes Note 19 Note 19 Note 19 None FUEL CIADDINC - RADIOACTIVITY CONCENIRATION OR RADIATION LVI.

IN CIRCUIATING PRIHARY COOIA Radioactivity Concentration or Radiation Level tn Prtnary Coolant Crab Saople

$ Tech. Spec.

Ltntt to 100 x Tech.

Spec. Ltutt No Inst, Exists In The Harket E-6372 FUEL CIADDINC ANALYSIS OF PRIHARY COOIANT Rx Cool. Ntr. Radtoacttvity Analysts 10 p. Ct/CC to 10 Ci/CC 10@. Ct/ml to 10 Ct/nl N/A N/A N/A N/A Note 15 SAS Yes Yes Rx COOIANI'RESSURE BOUNDARY RCS PRESSURE RCS Press.

0 - 3250 PSIC 0 - 3000 PSIC SEE ITEN Al PT-406 RCS Press.

ICCS A ICCS $

Dtsplay

>As Display'S'tO-%000 x 9 M

ITEM TAG NO VARIABLE DESCRIPTION TYPE CATE-GORY PARAHEIER LI Y SHEETS UNIT Y POINT INSTRUMENTRANGE EXISTING REQUIRED Q.A.

REQUIRE-MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION CR TSC EOF 21 OI 46 SCHEDULEI JUSTIFICATION C5 PT 6306A PI-6306A PR 6306A PT 63068 PI 6306B PR-63068 Rx COOIANF PRESSURE BOUNDARY CONIAIrDrENI'RESSURE Ctmt. Wide Range Press.

Ctmt. Mide Range Press.

Ind.

Ctmt. Wide Range Press.

Ctmt. Wide Range Press.

Ctmt. Mide Range Presa. Ind.

Ctmt. Wide Range Press.

C

~

0 - 180 PSIC

-5 PSIC to Design Pressure SEE ITEN B14 C6 PT-6425A PI 6425A PR 6306A PT-64258 PI 64258 PR-63068 Rx COOIAIrf PRESSURE BOUNDARY CONTAINHENT PRESSURE Ctmt. Narrov Range Press.

Ctmt. Narrov Range Press. Ind.

Ctmt. Narrov Range Press.

Ctmt. Narrov Range Press.

Ctmt. Narrov Range Press.lnd.

Ctmt. Narrov Range Press.

-6 to +18 PSIG

-5 PSIC to Design Pressure SEE ITEH B16 i

Ci LT-6308A Rx COOIANT PRESSURE BOUNDARY CONIAIh.KNT SUHP WATER IEVEL Ctmt.

Sump Water Level

-18 Ft. Elev. to El 14'-0" Narrov Range (Sump)

SEE ITEN B12 LI-6308A LR-6308A LT 63088 Ctmt.

Sump Mater Level Ind.

Ctmt.

Sump Mater Level Ctmt. Smy Water Level 0 - 369" 0 - 369"

-18 Ft. Elev. to El. 14'-0" LI-6308B IR-63088 Ctmt.

Sump Water Level Ind.

Ctmt.

Sump Water Level 0 - 369" 0 - 369" cpo. rxxo. x 9'a0

ITEM TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

GORY EXISTING REQUIRED PARAHETER LI UNIT 3 INSTRUMENTRANGE Y SHEETS POINT ENVIRONMENTAL O.A.

QUALIFICATION SEISMIC QUALIFICATION REDUN.

DANCE POWER SUPPLY CR TSC EOF DISPLAY LOCATION 46 SCHEDULE/

JUSTIFICATION LT 6309A LI 6309A LR-6309A LT-63098 LI 6309B LR 63098 Rx COOIANI'RESSURE BOU<<DARY CONIAINHKÃfSUHP WATER LEVEL Ctat. Mater Level Ctstt. Mater Level Ind.

Ctnt. Mater Level Ctnt. Mater Level Ctnt. Mater Level Ind.

Ctnt ~ 'Mater Level C

El. 14'" to El. 22'-0" 397" to 487" 397" to 487" El 14'-Oc to El. 22'-0" 397" to 487" 397" to 487" Wide Range

'lant Specific SKE ITKH B13 C9 D-631 1A RR 6311A D 6311B RR-6311B Rx COOIA<<f PRESSURE BOUNDARY CONTI<<HENT AREA RADIATION Ctcat.Hi Range Rad. Honitor

'h'tctt.HI Range Rad. )Smiter

'A'tnt.HI Range Rad. Honitor

'8'tnt.HI Range Rad. Hoaitor'8'0 10 R/HR.

IR/HR.

104 R/HR.

NIA N/A NIA N/A

<<ote 12 SAS Yes Yes SAS Yes Yes Yes C10 Rx COOIANF PRESSURE BOUNDARY EFFLUENT RADIOAC1'IVITY NOBLE CAS KFFLUK<<f FROH CO<<DE<<SKR AIR RE<<OVAL SYSTKH EXHAUST D 6417 Air Efector Condenser Exhaust 10 to 10 p Ci/CC 10 to 10

~C I/CC N/A NIA N/A N/A Note 12 SAS Ycs Yes CPO 9XXO x 9 al

PARANETER L UHNARY SHEETS UN1T Y POINT ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY CATE.

INSTRUMENTRANGE EXISTING

~

REQUIRED Q.A.

REQUIRE-MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

POWER DANCE SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULEI JUSTIFICATION Cll CONTAINMENT RCS PRESSURE RCS Press.

C 1

0 3250 PSIG 0 - 3000 PSIG SEE ITEN hl PT 406 ICCS A ICCS B Display shs Display

'8'E-6307h I-6307A RR-631lh E-63078 I 63078 RR-6311B CONTAINMENT Cliff H CONCENTRATION Ctat. H2 Honitor Ctat. H2 Indicator Ctat.

H2 Recorder Ctat. H2 Honitor Ctat.

H2 Indicator Ctat.

H2 Recorder C

1 0 - IOX 0 - 10 Vol.Z Coaply Note 1

Not'e 8 Note 8 Note I Note 8 Note 8 Note 10 AE 63078 Note 12 AI-63078 RR-6311B AE-6307A AI 6307A RR-6311A SAS Yes Ycs Yes Ycs SAS Yes Yes Ycs Yes C13 PT-6306A PI-6306A PR-6306A PT-6306B PI-6306B PR 6306B CONTAIlOENP CTHE. PRESSURE Ctat. Hide Range Press.

Ctat. Hide Range Press.

Ind.

Ctat. Hide Range Press.

Ctat. Hide Range Press.

Ctat. Mide Range Press.

Ind.

Ctat. Hide Range Press.

C 1

0 - 180 PSIG

-5 PSIG to 3X Design Pressure SEE ITEM B14 Ctn ~ %000 X 9/09

ITEM TAG NO.

VARIABLE DESCRIPTION GORY ATE.

EXISTING REQUIRED PARAMETER LI UNIT 3 INSTRUMENTRANGE Y SHEETS POINT REQUIRE ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN POWER DANCE SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULEI JUSTIFICATION CONTAIImtt CTNT.

PRESSURE (Continued)

PT-6425A Ctnt. Narrov Range Press.

PI-6425A Ctnt. Narrov Range Press.Ind.

FR-6425A Ctctt. Narrov Range Press.

FT-6425B Ctnt. Nsrrov Range Press.

PI-64258 Ctmt. Narrov Range Press.Ind.

PR-6425B Ctnt. Narrov Range Press.

C

~ I'6 to +18 PSIC

-5 PSIC to 3X Design Pressure SEE ITEN B16 C14 CONIAINHENI'l&l'.EFFLUENl'ADIOACIIVITY-NOBLE CAS PRON IDENTIFIED REIEASE POI ÃFS D-6304 Vent Stack Wfde Range Nonitor C

2 10 to 10

~Cf/CC k

10 to 10'Ci/CC NIA Note 8 NIA NIA Note 12 Yes Yes BAD-6417 Air E3ector Condenser Exh.

D-6426 Stean Line Rad. IIonftor SAS SAS Yes Yes Yes Yes CONTAINHEÃP - EFFUlENT RADIO ACTIVITYNOBLE CAS'(Froa Bldg or Areas, etc.)

D-6304 Vent Stack Wide Range Nonftor C

2 10 to 10

~CIICC 10 to 10

~ 0 I/CC SEE ITEN C14

PARAHETER L Y SHEETS UNIT POINT ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY ATE.

INSTRUMENTRANGE EXISTING

~

REQUIRED REQUIRE.

ENVIRONMENTAL SEISMIC MENT QUALIFICATION QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION CR EOF TSC SCHEDULE/

JUSTIFICATION Dl PT-605 PI-605 RHR SYSTEH RHR SYSTEH PLSJ RHR System Plov RHR System Plov Indicator 0 - 1102, Des(gn Plov I

Coeply Coeply Note Note 8 Note 10 Note 9 N/A N/A Note 12 SAS Note 12 cs Yes D2 TE-606 RHR SYSTEH RHR Hx OtEIET TEMPERATURE RHR Hx Outlet Temperature 50 - 400 P Note 6 Note 9 N/A Note 12 SAS Ycs Ycs TR-604 RHR Hx Outlet Temperature Recorder Co'uply Note 8 Note 10 N/A Note 12 es 03 LT-920 LI-920 LT-922 LI-922 LT-924 LI-924 LT-926 LI-926 LT-928 LI-928 LT-930 LI-930 S.I.S.

ACCIMllATOR TAMC LEVEL Accumulator Tank Level A'ccuaaalator Tank Level

'A'nd, Accumulator Tank Level

'A'ccumulator Tank Level

'A'nd.

Accumulator Tank Level

'8'ccumulator Tank Level

'8'nd, hccuamlator Tank Level

'8'ccueulator Tank Level

'8'nd.

Accumulator Tank Level

'C'ccuamlator Tank Level

'C'nd.

Accumulator Tank Level

'C'ccumulator Tank Level

'C'nd.

D 2

6133 6761 CAL (Harrov Range) 6000 7000 CAL 6133-6761 CAL (Narrov Range) 6000 7000 CAL 6133-6761 CAL (Narrov Range) 6000-7000 CAL 6133-6761 CAL (Narrov Range) 6000-7000 CAL 6133-6761 CAL (Nsrrov Range) 6000-7000 CAL 6133-6761 CAL (Narrov Range) 6000 7000 CAL IOE to 90E Volume H111 Cockily Comply

'H111 Comply Comply N111 Coeply Comply Hill Coeply Coop ly Hill Coop 1y Coeply N111 8

Comply Coeply Note 2 Note 8 Note 2 Note 8 Note 2 Note 8 Note 2 Note 8 Note 2 Note 8 Note 2 Note 8 Note 11 Note 9 Note 11 Note 9 Note 11 Note 9 Note 11 Note 9 Note 11 Note 9 Note 11 Note 9 LT-922 LI 922 LT-920 LI-920 LT-926 Ll-926 LT-924 LI-924 LT-930 LI-930 LT-928 LI-928 Note 12 SAS Yes SAS Yes Yes Ycs Ycs Ycs Yes Ycs Ycs Ycs Yes Yes Ycs Ycs Yes Ycs Note 24 6 30 Note 24

& 30 Note 24 6

30 Nots 24 6 30 Note 24 6 30 Note 24

& 30 cao.axan-a s sl

PARAHETER Ll Y SHEETS UNIT 3 POINT ITEM TAG NO.

VARIABLE DESCRIPTION TYPE ATE.

ORY INSTRUMENTRANGE EXISTING REQUIRED Q.A.

REOUIRE.

MENT ENVIRONMENTAL SEISMIC OUALIFICATION QUALIFICATION REDUN.

POWER DANCE SUPPLY DISPLAY LOCATION TSC CR EOF SCHEDULE/

JUSTIFICATION PT-921 PI-921 PT-923 PI-923 PT-925 PI-925 Ff-927.,

PI-927 PT-929 PI-929 PT-931 PI-931 S.I.S. - ACCUNUIATOR TANK PRES SURE Accumulator Tank Pressure

'A'ccumulator Ind.

Accumulator fe~usmlator Accumulator Accumulator Ind.

Accumulator Accumulator Ind.

Aecusmlator Accumulator Ind.

Accumulator Tank Pressure

'A'ank Prcssure

'A'ank Pressure

'A'ant Prcssure

'B'ank Prcssure

'B'ank Pressure

'8'ant Prcssure

'B'ank Pressure

'C'ank Pressure

'C'ank Pressure

'C'ccumulator Tank Prcssure

'C'nd.

0 800 PSIC 0 - 750 PSIC Comply Note I Note 8 Note I Note 8

Note 1

Note 8 Note 1

Note 8 Note I Note 8 Note 1

Note 8 Note 10 Note 9 Note 10 Note 9 Note 10 Note 9 Note 10 Note 9 Note 10 Note 9 Note 10 Note 9 PI-923 PT-921 PI-921 Yes Yes PT-927 PI-927 PT-925 PI-925 PT-931 PI-931 PT-929 PI-929 Ycs Ycs Yes Yes PT-923 Note 12 SAS Yes Yes Yes Yes Ycs Ycs Yes Yes Yes Yes HOV-865A HS 865A

-8658 HS-865B

. OV-865C 8-8650 S.I.S.

ACCUMIIATOR ISOIATIOI VALVE POSITION Accusalator Tank Isolation Valve 'As Aecusmlator Tank Isolation Valve she Accumulator Tank Isolation Valve

'B'ccumulator Tank Isolation Valve

'8'ccumulator Tank Isolation Valve

'C'ccumulator Tank Isolation Valve

'C'losed or Open Closed ot Open Comply See Schedule/

Justification See Schedule/

Just ii cation N/A Note 13 Ycs Ycs Yes Yes Ycs Ycs Yes Yes Yes These Valves hre Locked Open Epo ~ 1xos s siM

PARAMETER II UNIT 3 1 SHEETS POINT S> ~yaf 46 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE ATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE REQUIRE ENVIRONMENTAL Q.A.

MENT QUALIFICATION SEISMIC QUALIFICATION REDUN-POWER DANCE SUPPLY DISPLAY LOCATION TSC CR EOF SCHEDULE/

JUSTIFICATION D6 PT-943 FI-943 S.I.S.

BORIC ACID CHARCINC FFISKS Boric Acid Charging Flow Boric Acid Charging Flov Ind.

0 1000 CPM 0

I ICE Des iga Plov Coop ly Coop ly Note 1 Note 8 Note 10 Note 9 N/A N/A Note 12 SAS Note 12 Yes Yes Yes Dy PT-940 FI-940 S.I.S.

FLOM IN HPI SYSTEM HPI Systea Flow HPI Systea Flov Ind.

2 0 - 1000 CPH 0 - IIOI Desiga Flov Coaply Cocply Note 1

Note 8 Note 10 Note 9 N/A N/A Note 12 SAS Note 12 Ycs Yes Yes DB IT-605 F1-605 S.I.S. - FL$1 IN LPI SYSTEM LPI Systea Flow LPI Systes Flow Ind.

0 - 1000 CPM 0 - LION Design Plov Coaply Coaply Note 1

'Note 8 Note 10 Note 9 N/A Note 12 N/A Note 12 Yes 09 LT-6583A LI-6583A LT-6583B Ll-6583B S.I.S. - REFUELINC HATER STORACE TANK RUST Level INST Level Indicator RMST Level INST Level Indicator 2.

0 - 330,000 Cal.

Top to Bottoa SEE ITEH A4 cital sxoo x s ss

0

PARAMETER LI Y SHEETS UNIT 3 POINT 12 OI 46 ITEM TAG NO.

VARIABLE DESCRIPTION GORY CATE.

EXISTING REQUIRED INSTRUMENTRANGE REQUI'RE ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN POWER DANCE SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULE/

JUSTIFICATION D10 3P200C RCP 'B'tz'. Current Indfcato RCP 'C'tr. Current RCP 'C'cr. Current Indfeato PRIMARY COOIAHT SYSTEM RCP MOIOR STATUS 3P200A RCP 'A'tr. Current RCP 'A'tr. Current Indfcato 3P200B RCP 'B'tr. Current D

3 0 - 1200 AHP Htr. Currenr.

N/A N/A N/A N/A Note 16 Hotc 14 Note 16 Note 14 Hoes 16 Note 14 No Yes No Yes Ycs No No No No No No Dll PRIMARY COOIANt SYStEM PRIMARY SYSTEM SAFETY RELIEF VALVE POSITION PCV. 455C PRZR PORV PCV-456 PRZR PORV Posftfon Indfeatfon LfBhts for PCV 455C 4 456 ZS-6303A Prfuary Sysccn Safety R,V.

Code Safety Valve ZS-6303B Prfnary Systcn Safety R.V.

Code Safety Valve ZS-6303C Prfnary Systems Safety R.V.

Code Safety Valve Open Closed Closed Noc Closed Closed Not Closed Cosply Conply Coop ly Note 1 Mote 1 Note 1

Note 10 Note 10 Note 10 N/A N/A N/A N/A N/A Note 14 Note 14 Hoes 12 Rote 12 Note 12 Yes Ycs Yes Ycs Yes Ycs Yes Ycs Yes Yes Yes Readout In CR for ZS-63064, B> C N/A Note 12 ceo sÃoo ~ a 9 ss

PARAMETER LI UNIT 3 SHEETS POINT S ~of 46 ITEM TAG NO.

D12 VARIABLE DESCRIPTION PRIMARY COOLANT SYSTEM TYPE CATE-GORY EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE-MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN DANCE POWER SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULE/

JUSTIFICATION LT-459 LI-459 LT-460 LI-460 LT-461 Ll-461 LR-459 PRESSURIZER lEVEL PRZR Level Ch. I PR2R Level Ch. I Ind.

PRZR Level Ch. II PRZR Level Ch. II Ind.

PRZR Level Ch. III PR2R Level Ch, 111 Ind.

PRZR Level Recorder for LT 459, 460, 461 0 - 181" 0 - 100'Z 0

181" 0 - IOOZ 0

181" 0

IOOZ 0 - 1001 Top to Bottom Comply Note I Note 8 Note 1

Note 8 Note 1

Note 8 Note 8 Note 10 Note 9 Note 10 Note 9 Note 10 Note 9 Note 10 LT-460 LT-461 I.I 460 LI-461 LT 459 LT 461 LI-459 LI 461 LT 459 LT-460'I-459 LI 460 N/A Note 12 SAS Yes Ycs Ycs Yes SAS D13 3811 3812 3813 PRIMARY COOLANP SYSTEM PRESSURIZER HEATER STATUS PRZR Heater Status PRZR Heater Status Indicating Light PRZR Heater Status PRZR Heater Status Indicating Light PRZR Heater Statue PRZR Heater Status Indicating Light On-Off Light On-Off Light On-Off Light Current Hill Comply Comply Hill Comply Comply

'Hi1I Comply Comply Note 2 Note 8 Note 2

Note 8 Note 2 Note 8 Note ll Note 9

-Note 11 Note 9 Note 11 Note 9 N/A Note 17 Note 14 Yes Note 17 SAS Note 14 Nota 17 SAS Note 14 Ycs Yes Yas Yes Yes Note 24 Ycs Note 24 Yes Note 24 014 PRIMARY CMIANP SYSTEM UENCH TANK LEVEI LT-470 LI-470 PRZR Relief Tank Level (Oucnch Tank)

PRZR Relief Tank Level Indicator (quench tank) 0 IOOZ Top to Bottocs N/A N/A N/A N/A N/A N/A NIA N/A Note 12 SAS Nota 12 Yes Yes Ycs ciao $Ã0o x s.ss

PARAMETER LISTI Y SHEETS UNIT 3 INP.

12/

Sn ITEM TAG NO.

D15 VARIABLE DESCRIPTION PRIMARY COOIANY SYSTEM UENCH TANK TEMPERATURE TYPE GORY CATE.

EXISTING

~

REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN-POWER DANCE SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULE/

JUSTIFICATION TI-471 PRZR Rcllef Tank Teaperature Indicator TE-471 PRZR Rclfsf Tank Tecperaturc 50 350 P N/h NIA NIA NIA N/A Note 12 SAS Note 12 Yce Yes Yes D16 PI-472 PRZR Relfef Tank Pressure Indicator PRIMARY COOlhNl'YSTEM UENCH TANK PRESSURE Pl'-472 PRZR Relief Tank Pressure 0 - 120 PSIC 0-Design Press.

NIA NIA NIA N/h NIA NIA NIA N/A Note 12 SAS Note 12 Ycs Ycs Ycs D17 IT-474 LI-474 LT 475 LI&75 LT-476 LI 476 LR-478 SECONDARY SYSTEM (Stean Cen.)

S.C.

LEVEL S.C. 'h'evel Ch. I Narrow Range S C

<<As Level Ch. I Narrow Range Ind.

S,C. 'A'evel Ch.

11 Narrow Range S.C. lh'evel Ch. Il Narrow Range lnd.

S 0 ahab Level Ch. III Narrow Range S.C. 'A'evel Ch. III Narrow Range Ind.

S.C. 'A'evel Ch. I, 11, 111 Recorders

- Narrow Range D

1 30 1" to 138.11" 0 - IOOZ 30.1" to 138.22" 0 - IOOZ 30.1" to 138.22" 0 - IOOZ 0 - IOOZ Pron Tube Sheet to Separators SEE ITEM h5 Note 25 llXO~ X %el

PARAMETER Ll RY SHEETS UNIT 3 'I POINI'1 0I 46 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE-MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN POWER DANCE SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULEI JUSTIFICATION LT-484 LI-484 LT-485 LI 485 LT 486 LI-486 LR-488 SECONDARY SYSTEM STEAM CENERA R

S.C.

LEVEL (Continued)

S.C. '8'evel Ch. I Narrov Range S.C. '8'evel Ch. I Harrow Range Ind.

S.C. '8'evel Ch. II Narrow Range S.C. '8'evel Ch. 11 Narrow Range Ind.

S.C. 'B'evel Ch. III Narrow Range S.C. 'B'evel Ch. III Nsrrov Range Ind.

S.C. '8'evel Ch. I; 11, 111 Recorders 30.1u to 138.22u 0 - 1007 30.1" to 138.22" 0 - 100%

30.1u to 138.22" 0 - IOOE 0 - ICOS Froa Tube Sheet to Separators SEE ITEM A5 Note 25 LT<94 LI-494 LT-495 LI 495 LT-496 LI-496 LR 498 S.C. 'C'evel Ch. I Harrov Range S.C, 'C'evel Ch. I Narrou Range Ind.

S C AC> Level Ch. 11 Narrow Range S.C. 'C'evel Ch. II Narrow Range Ind.

S.C. 'C'evel Ch. 111 Narrov Range S.C. 'C'evel Ch.

111 Hsrrov Range Ind.

S.C. 'O'evel Ch. I, II, III Recorders 30.1" to 138 22u 0 - 1001 30 lu to 138.22" 0

100X 30.1" to 138.22" 0

1001 0

1002 cpo axKu x s/sl

PARAHETER L Y SHEETS UNIT POINI'18 TAG NO VARIABLE DESCRIPTION SKCONUARY SYSTKH S.C.

S.C.

PRESSURE TYPE ATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN-DANCE POWER SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULEI JUSTIFICATION PT-474 PI-474 PT-415 PI-475 Pf-416 PI-476 S.C. 'A'tcam Pressure Ch. II S.C. 'A'team Pressure Ch. II Ind.

S.C. 'A'team Prcssure Ch. III S.C. 'A'team Prcssure Ch.

111 Ind.

S.C. 'A'team Pressure Ch. IV S.C. 'A'tcam Pressure Ch. IV Ind.

0 - 1400 PSIC PROH ATHOS.PRESS TO 201 Above Loucst S.V.

Settfn Comply Note I Note 8 Note I Note 8 Note I Note 8 Note 10 Note 9 Note 10 Note 9 Note 10 Note 9 PT-475 PT-476 PI-475 PI-476 PT<74 PT-476 PI474 PI<76 PT-474 PT-475 PI-474 PI-475 Note 12 SAS Ycs Ycs SAS Yes SAS Ycs Yes Yes Ycs Yes PT-484 PI-484 PT-485 PI-485 PT-486 PI-486 S.C. '8'tcam Pressure Ch. II S.C. '8'team Prcssure Ch. II Ind.

S.C. 'B'team Pressure Ch. III S.C. '8'team Pressure Ch. 111 Ind.

S.C.

8'tcam Pressure Ch. IV S.C, '8'team Pressure Ch. IV. Ind.

Note I Note 8 Note I Note 8 I'ote I Note 8 Note 10 Note 9 Note 10 Note 9 Note 10 Note 9 PT-485 Pr-486 PI-485 PI<86 PT-484 PT-486 PI-484 PI-486 PT<84 PT-485 PI-484 PI-485 SAS Yes Yes SAS Ycs Ycs SAS Yes Yes Yes Yes Yes PT-494 Pl-494 PT-495 S.C. 'O'team Pressure Ch. II S.C. 'C'team Pressure Ch. Il Ind.

S.C. 'C'team Pressure Ch. 111 Note 1

Note 8 Note 1

Note 10 Note 9 Note 10 PT-495 PI<96 PI-495 PI-496 PT-494 PT-496 SAS Yes Yes SAS Yes Yes Yes rto ~ aaaoo x 9 el

PARAHETER LIST UNlT 3 TU Y SHEETS POINT She OI 46 ITEM TAG NO VARIASLE DESCRIPTION SECON(WRY SYSTEM S.C STEAN CENERATOR PRESSURE (Continued)

GORY CATE-INSTRUMENTRANGE EXISTING

~

REQUIRED Q.A.

REQUIRE-MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

POWER DANCE SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULE/

JUSTIFICATION PI-495 PT-496 PI-496 S.C. 'C'tean Pressure Ch. IIIInd, S.C. 'C'tean Pressure Ch. IV S.C. 'C'tean Pressure Ch. IV lnd.

0 - 1400 PSIC:

FROM AIHOS.PRESS TO 202 Above Louest S.V.

Setting Coop ly Note 8 Note 1

Note 8 Note 9 Note 10 Note 9 PI-494 Pl-496 PT-494 PT 495 PI-494 PI-495 Note 12 Yes SAS Yes Ycs Yes 019 RV-1400 RV-1405 SECONDARY SYSTEH S.C.

SAFEIY/RELIEF VAIVE POSITIONS OR HAIN STEAN FUN Hain Stean Safety Valve Position Hain Stean Safety Valve Position None Closed Not Closed ee Schedu ustificsti See Schedule/

Justification Sec Schedule/

Justification The Hain Stean Safety Valve Pos-ition Indication ls Honltored by Heasurlng Hain Stean Flou RV-1410 RV 1401 RV 1406 Hain Stean Safety Valve Position Hain Stean Safety Valve Position Hain Stean Safety Valve Position RV-1411 RV-1402 RV 1407 Hain Stean Safety Valve Position Hain Stean Safety Valve Position Hain Stean Safety Valve Position RV-1412 RV 1403 Hain Stean Safety Valve Position Hain Stean Safety Valve Position cto ~ aaxo. a 9."s)

PARAMETER LISTING

SUMMARY

SIIEETS UNIT 3 TURKEY POINT

. 12/83 Sheet~ of~

ITEM TAG NO.

VARIABLE OESCRIPTION TYPE ATE.

GORY EXISTING

~

REQUIREO INSTRUMENTRANGE ENVIRONMENTAL Q.A.

QUALIFICATION SEISMIC QUALIFICATION REOUN-POWER DANCE SUPPLY IIISPLAY LOCATION TSC EOF SCHEDULE/

JUSTIFICATION RV 1408 RV 1413 SECONDARY SYSTEH S:C.

SAFETY/RELIEF VALVE POSITIONS OR HAIN STEAM FLOM (Contfnued)

Hain Stone Safety Valve Position Hain Stean Safety Valve Position None Closed Not Closed See Schnhte/

Justf fice See Schedule/

Justi fcation See Schedule/

Justi fcation The Hain Stean Safety Valve Pos-ition Indication ls Monitored by Measuring Main Stean F lov D20 FT-476 FI-476 rf-477 FI-477 FT-486 FI-486 IT-487 FI-487 FT-496 FI-496 PT-497 FI-497 S.C. ~A'.'M.

Ind.

S,c.

sAs F.M.

Flov Ch. III Flov Ch. IV Flov Ch. IV Flov Ch. III Flov Ch. III Flov Ch. IV Flov Ch. IV Flov Ch. III Flov Ch. III Flov Ch. IV S.G. 'A'.M.

Ind.

S.G. 'B'.M.

S.C. '8'.'M.

Ind.

s.c. '8'.M.

s.c. '8'.M.

Ind.

s.c. 'c'.M.

s.c. 'c'.M.

Ind.

S.C.

CI F M S.C. 'C'.M. Flov Ch, IV 1nd.

SECONDARY SYSTEM S.c HAIN FKKDMATKR FLOM S.C. 'A'.M. Plov Ch. III 0 - 4 x 10 LB/BR 0 - IIOE Desi8n Flow N/A N/A N/A N/A Note 12 SAS Yes

'cs Yes Yes Yes Ycs Tes Yes Tes Yes Yes Yes Yes Ycs Tes Yes Ycs Yes l'po sxoo x s ss

PARAMETER LISTINC SIDDIARY SHEETS UNIT 3 TURKEY POIIrr 12/83 Sheet~ Of~4 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE ATE.

GORY INSTRUMENTRANGE

~

REQUIRED EXISTING Q.A.

REQUIRE-MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN.

POWER DANCE SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULEI JUSTIFICATION D21 FT-1401A FI 1401A FT-14018 FI 14018 PT-1457A FI-1457h IT-14578 FI-14578 FT-1458A FI 1458A FT-14588 FI-14588 AUXILIARYFEEDWATER AUXILIARYFEEDWATER FUN Aux. F.'W. Flow to S.C.

'h'ux.

P.W. Flow to S.C she Ind.

Aux. F.W. Flow to S.C.

'h'ux.

P.'W. Flow to S.C.

'A'nd.

Aux. P.W. Flow to S.C sB Aux. P.W. Flow to S.C.

'8'nd.

Aux. P.'M. Flov to S.C.

'B'ux.

P.'W. Flov to S.C.

'B'nd.

Aux. P.W. Flow to S.C

'Cs hux. F.W. Plov to S.C.

'C'nd.

Aux. F.Q. Flow to S.C.

'C'ux.

F.N. Flov to S.C sC Ind.

0 - 300 CPM 0 - IIDE Destgn Flov Conply Note I Note 8 Note I Note 8 Note 1

Note 8 Note 1

Note 8 Note I Note 8 Note I Note 8 Note 10 FT-14018 Note 12 FI-1401B FT 1401A FI 1401A FT 14578 PI 14578 FT-1457A FI 1457A FT 14588 FI-14588 FI-1458A PI-1458A SAS Ycs Ycs SAS Yes Yes SAS Ycs Yes SAS Yes Yes SAS Yes Yes SAS Yes Ycs Note 23 D22 AUXILIARYFEEDWATER CONDENSATE STORAGE TANK WATER LEVEL LT-6384A LI-6384A LT-6384B LI-63848 Condensate Storage Tank Condensate Storage Tank Ind.

Condensate Storage Tank Condensate Storage Tank Ind.

0 - 1002 Plant Spcctftc Coeply Note I Note 8 Note I Note 8 Note 10 LT-63848 Note 12 LI-63848 LT-6384A LI 6384A SAS Yes Ycs SAS Yes Ycs

PARAHEIER LISTING SUHHARY SHEETS UNIT 3 TURKEY POINT 12/83 ShOBI 36 OI 46 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY'TE.

EXISTING REQUIRED INSTRUMENTRANGE O.A.

REQUIRE-MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

POWER DANCE SUPPLY DISPLAY LOCATION TSC EOF SCHEDULEI JUSTIFICATION D23 None CONIAIIOfENF COOLING SYSTEH CONIAINHENI'PRAY FLOW Contafnmcnt Spray Floe D

~

2 0 - IIOZ Design Flou See Sdadule/

Justfffcatbn See Schedule/

Justification See Schedule/

Just fficat1on The Operation of the Ctat. Sprar System fs Honftor ed by the Ctmt.

Spray hctuatfon Signal, The indic-ation of Pump Starting and Vair Position Indfcaucr fn the Control Roca D24 CONTAINHENT COOLING SYSTEH HEAT REHOVAL BY THE CIHF FAN HEAT REHOVAL SYSTFJI TE-1481 Ctet. Cooler Air Teep. Outlet TE-1483 Ctmt. Cooler Air Teep. Inlet TE 1482 Ctat. Cooler Air Teep. Outlet TE-1484 Ctet. Cooler Air Temp. Inlet TE-1485 Ctat. Cooler Afr Temp. Outlet TE-1487 Ctat. Cooler Air Teep. Inlet TE-1486 Ctmt. Cooler hlr Temp. Outlet TE-1488 Ctet. Cooler Air Temp. Inlet R-1413 Ctat. Temp. Recorder D

2 0 - 300 F Plant'pecific N/A Note 3 Note 8 Note 9 N/A Note 15 Yes Yes Yes D25 R-1413 Ctat. Temperature Recorder CONIAINHENF COOLING SYSTEH CIHI'. ATHOS. TEHPFRATURE TE-1497 Ctat. Atmos. Temperature TE-1498 Ctat. Atmos. Temperature.

TE-1499 Ctat. Atmos. Temperature D

2 0

300 F 40 - 400 F N/A Note 3

Note 8 Note 9 TE-1498 TE-1499 TE-1497 TE-1499 TE-1497 TE-1498 N/A Note 15 Yes Yes Turkey Point Hax Ctet.

Temp.275OF ceo. %000 ~ x assi

PARAHETER LISTINC SURIARY SHEETS UNIT 3 TURKEY POINT 12/83 Sheet~ otic ITEM 026 TAG NO.

Noae VARIABLE DESCRIPTION CONTAINMENP COOLINC SYSTEM CONTAINMENI'UMP MIR. TEMP.

Ctmt.

Sump Ntr. Temperature TYPE CATE.

GORY INSTRUMENTRANGE EXISTING REQUIRED 50 - 250 F Q.A.

REQUIRE-MENT See Schofule/

Justfffasfon ENVIRONMENTAL QUALIFICATION See Schedule/

Justfffcatfon SEISMIC QUALIFICATION See Schedule/

Justfffcatfon REDUN.

DANCE POWER SUPPLY TSC EOF DISPLAY LOCATION SCHEDULEI JUSTIFICATION A Heasuremcnt of the ctmt.asap Nrr.

Temp. fs Accom-plfshed vfth the R.C. Hot Leg Tesp.

The Hater In tbe Sump vfll be Aluays Belov the Hot Leg Tempera-

ture, D27 CHEHICAL & VOLUME CONIROL SYSIEM - MAKEUP FllN PT-122 Chargfng Flov PI-122 Chargfng Plov Ind.

0 - IIOE Des fgn Flov Comply Comply Note I Note 8 Note 10 Note 9 N/A N/A Note 12 SAS Note 12 Yes Yes D28 CHEMICAL & VOLUME CONIROL SYSTEM IETDOMN FIAM FI-150 Lo Pressure Letdoun Plou Ind.

FT-150 Lo Pressure Letdoun Flov 0

150 CPH 0 - IIDE Deaf gn Plov Comply Comply Note 1

Note 8 Note 10 Note 9 N/A N/A Note 12 SAS Note 12 Yes Tcs Yes D29-CHEMICAL & VOIJIME COÃIROI.

SYSTEM VOLUME CONTROL TANK LEVEL LT-115 Vol. Control Tank Level LI-115 Vol. Control Tank Level Ind.

LT-112 Vol. Control Tank Level LI-112 Vol. Control Tank Level Ind.

0 - 1002, Top to Bottom Comply Note 3 Note 8 Note 3 Note 8 Note 9 N/A Note 12 SAS Yes SAS Ycs Ycs Yes Yes Yes ruo 22ooo x 2 s2

PARAHKIER LISTING SUNHARY SHEETS UNIT 3 TURKEY POINT 12/83 Sheet~ oi~4 TAG NO.

VARIABLE DESCRIPTION TYPE GORY ATE.

EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN POWER DANCE SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULE/

JUSTIFICATION D30 COOLING MATER SYSTEH COHPONKNT COOLING MATER TEMP.

TO ESF SYSTKN TE-607A TI-607A TE-607B TI-607B Component Cooling Hx Outlet Te mp cra 'tu're Component Cooling Hx Outlet Temperature Ind.

Companent Cooling Hx Outlet Temperature Component Caoling Hx Outlet Temperature Ind.

D 2

50 - 200 F 40 - 200 F Comply Nate 3

Note 8 Note 3 Nota 8 Note 9 N/A Note 12 Ycs SAS Tes Yes Yes D31 COOLING WATER SYSIKH CCHPONKNT COOLING 'MATKR FLOW TO KSP SYSTEN FT-613A CCM Header Flov FI-613A CCM Header Flow Ind.

FT-613B CCM Header Plow PI-6138 CCW Header Plow Ind. '

- 14000 CPH 0 - IIOK, Design Flov Comply Comply Comply Comply Note 1

Note 8 Note 1

Note 8 Nate 10 Note 9 Note 10 Note 9 N/A Note 12 SAS Yes Yes SAS Yes Yes Yes Yes D32 RADMASTE SYSTKHS - HIGH LEVEL RADIOACTIVITY D. TANK LEVEL LT-1001 Masts Holdup Tank Level LI-1001A Masts Holdup Tank Level Ind.

0 -.IOOK Top to Bottom N/A N/A N/A N/A N/A N/A Note 15 SAS Yes Note 15 Yes Yes Pneumat ic cpo oooo x s,ss

ITEM TAG NO.

VARIASLE DESCRIPTION TYPE GORY ATE.

PARAMElER LISTINC SWARY SHEETS llNIT 3 TURKEY POINT INSTRUMENTRANGE EXISTING

~

REQUIRED O.A.

REQUIRE-MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN.

DANCE POWER SUPPLY 12/83 DISPLAY LOCATION CR TSC EOF SCHEDULE/

JUSTIFICATION Sheet ~9 Of 46 D33 PY-1036 PI-1036 PY-1037 Pl-1037 PT-1038 PI-1038 FI-1039 PI-1039 PT 1052 PI-1052 PI-1053 PI-1053 RADUASTE SYSTEIlS RADIOACTIV CAS HOLDUP TANK PRESSURE Cas Decay Tank

'A'Holdup)

Pressure Cas Decay Tank

'A'Holdup)

Pressure Ind.

Cas Decay Tank

'8'Holdup)

Pressure Cas Decay Tank

'8'Holdup)

Pressure Ind.

Cas Decay Tank

'C'Holdup)

Pressure Css Decay Tank

'C'Holdup)

Pressure Ind.

Cas Decay Tank

'Ds (Holdup) Pressure Cas Decay Tank

'D'Holdup)

Pressure Ind.

Cas Decay Tank

'E'Holdup)

Pressure Cas Decay Tank

'E'Holdup)

Pressure Ind.

Cas Decay Tank

'P'Holdup)

Pressure Cas Decay Tank

'P'Holdup)

Pressure Ind.

D 3

0 - 100 PSIC 0 to 1502 Design Pressure N/A N/A N/A Note 15 Note 18 Note 15 Note 18 Note 15 Note 18 Note 15 Note 18 Note 15 Note 18 Note 15 Rotc 18 SAS Yes Ycs Yes SAS Yes Ycs Yes SAS Yes Yes SAS Yes Yes SAS Ycs Yes Ycs SAS Yes Ycs Dl D2 VFNFIlATION SYSTEH-EHERCENCV VFNFIIATION OAHFFR FOSlTION C.R. Homal Intake Deeper Posltlon C,R. Energency Intake Deeper Posltlon 4

6 Open Closed Open Closed Coeply Coop ly Note 1

Note 8 Note 10 Note 9 N/A Note 13 Note 13 SAS Yes Yes

@to. Nooo ~ x s sj

PARAMETER LISTIIC SUIOIARY SHEETS UNIT 3 TURKEY POINT 12/83 Sheef 40 Of 46 ITEM TAG NO.

VARIABLE DESCRIPTION VENI'IihTIOH SYSTEM-EMERGENCY VEHTIIATION DAMPER POSITION (Continued)

TYPE CATE.

GORY EXISTING

'REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE-MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN-POWER DANCE SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULE/

JUSTIFICATION D3 C.R. Emergency Intake Damper Pos itioa D

Open Closed Open Closed Comply Note 8 Note 9 N/A Note I SAS Yes Dl1 C.R. Recirculating Damper Position Comply Note 8 Note 9 N/A Note 1

D35 3K4 AMP 3K4 AMP PIKIER SUPPLIES-STATUS OF STANDBY PiNER 6 OTHER ENERGY SOURCES IMPORTANT TO SAFETY Emergency Diesel Cen.

'h'urrent to Unft 3 Emergency Diesel Cen.

'A'urrent to Unit 3 Emergency Diesel Cen.

'A'urrent to Unit 4 0 - 600 AMPS AMPS 0

600 AMPS AMPS AMPS Note 8 Note 9 N/A Note 1

SAS Yc9 Yes SAS Yes Yes Emergency Diesel Cen.

'A'urrent to Unit 4 Yes 3K4 VOLTS DC VOLTS Onsite Emergency Pouet Unit 3 One ite Emergency Pouer'nit 3

0 5000 VAC VOLTS VOLTS VOLTS SAS Yes Yes Ycs 3B05 3B06 3B07 3808 3BOI LC3A MCC 3A Bus Voltage MCC - 38 Bus Voltage MCC - 3C Bus Voltage MCC - 30 Bus Voltage Load Center 3A Volt Status Load Center 3A Volt Status 0 - 600 VOLTS VOLTS 0 - 600 VOLTS 0 - 600 VOLTS 0 - 600 VOCI'S VOLTS VOLTS VOLTS VOLTS VOLTS 0

600 VOLTS

'VOLTS SAS Yes Yes Yes

~ SSXm a 9 99

PARAMETER LISTING SUHMARY SHEETS UNIT 3 TURKEY POIlfP 12/83 Sheet 41 of 46 ITEM TAG NO.

VARIABLE DESCRIPTION GORY CATE.

EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE-MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION RE DUN.

POWER DANCE SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULEI JUSTIFICATION 3B02 LC38 3B03 LC3C 3804 LC3D 3YOl 3YOl 3Y02 3Y02 3Y04 3Y05 3Y05 3Y06 3Y06 3YOT 3YOF PS-2322 PS-2323 Later POUER SUPPLIES STATUS OF STANDBY PONER 6 OIBER ENERCY SOURCES IMPORTANT TO SAFETY (Continued)

Load Center 3B Volt Status Load Center 3B Volt Status Load Center 3C Volt Status Load Center 3C Volt Status I.oad Center 3D Volt Status Load Center 3D Volt Status 120 VAC Invertcr 3A Cuerent 120 VAC Inverter 3A Voltage 120 VAC Inverter 3B Current 120 VAC Inverter 3B Voltage 120 VAC Inverter h5 Current 120 VAC Inverter A5 Voltage 120 VAC Inverter 3C Current 120 VAC Inverter 3C Voltage 120 VAC Inverter C5 Current 120 VAC Inverter C5 Voltage 120 VAC Inverter 3D Current 120 VAC Inv rtcr 3D Voltage N2 Supply for hux. F.N. Cont.

Valves Pressure N2 Supply for Aux. F.N. Cont.

Valves Prcssure N2 Supply for PORV'S 0 - 600 VOLTS VOLTS 0

600 VOLTS VOLTS 0

600 VOLTS VOLTS 0 - 100 AMPS 0

150 VOLTS 0 - 100 AHPS 0

150 VOLTS 0 - 100 AHPS 0 - ~ 150 VOLTS 0

100 AMPS 0 - 150 VOLTS 0

100 AMPS 0 - 150 VOLTS 0 - 100 AHPS 0 - 150 VOLTS 300 to 2500 PSIC VOLTS VOLTS VOLTS VOLTS VOLTS VOLTS VOLTS AHPS VOLTS VOLTS AMPS VOLTS VOLTS AMPS

, VOLTS Pressure Coop ly Note 8 Note 9 N/A Note 13 SAS Yes Ycs Yes SAS Yes Yes Yes SAS Yes Yes Ycs Note 12 SAS Yes Yes Note 14 SAS Yes Yes Note 14 cd

~ ssxo x s sl

0

PARAHETER LISTING SUIOIARY SHEETS UNIT 3 TURKEY POINf 12/83 Sh OUI 42 Of <<

ITEM TAG NO.

VARIASLE DESCRIPTION TYPE CATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE QJI.

REQUIRE-MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION TSC EOF SCHEDULEI JUSTIFICATION RAD-631IA RR-6311A RAD 63118 RR-63118 CONfAINHENf RADIATION CONfAII&EÃfAREA RADIATION Hl RANGE Ctnt. High Range Rad.

Nonitor Ch.

'A'tnt.

High Range Rad. Honitor Ch. 'A'ecorder Ctnt. High Range Rad.

Ch.

sB'tnt.

High Range Rad. Honltor Ch. 'B'ecorder 10 to 10 R/HR.

I R/HR to 10 R/HR Coop ly Note 1

Note 8 Note 1 Note 8 Note 10 RAD 63118 RR-63118 RAD-631 IA RR 6311A Note 12 SAS Yes Yes Yes Yes Yes Yes E2 RD-1417 RD-1418 RD 1419 RD-1420 RD 1415 RD-1416 RD-1413 RD-1414 R-1405 AREA RADIATION RADIATION EXPOSURE RATE East End of E/N Corridor Nest End of E/N Corridor Spent Fuel Pit Exhaust Control Roon North End of N/S Corridor South End of N/S Corridor Outside Sasple Rn. - Unit 3 Outside Sanple Rs4 - Unit 4 Recorder 10-1 to 103 HR/HR.

10-1 to 104 R/HR.

N/A Note 8 N/A N/A Note 12 SAS Yes Yes Yes Note 27 cto.lxxo.x i ss

0 0

PARAMETER LISTINC SUNIARY SHEETS UNIT 3 TURKEY POINT 12/83 Sheet~ oi~

ITEM TAG NO.

VARIABLE DESCRIPTION TYPE CATE-GORY EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE-MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN POWER DANCE SUPPLY DISPLAY LOCATION TSC EOF CR SCHEDULE/

JUSTIFICATION E3 AIRBORNE RADIOACTIVE MATERIA RELFASKD FROM FIAT'OBLE CAS 4 VKHT FUKI RATE None Ctnt. or Purge Effluent 10 p'Ct/CC to 10 /ACt/CC No Inst. Kxfsrs None Ctnt. or Purge Kffluenr (Flov)

E 0 - 1107 Design Flov No Inst. Exists Reactor Shield Blg. Annulus THIS DESIGN N USED ON TURKEY IHT No Inst. Exfsts None Auxiliary Building Auxiliary Building (Flov)

NOTE:

TURKEY 10 J1Cf/CC to 10 p.Ct/CC 0 - IIOK Design Flov OINT HAS CONN IAHT VERI' R ALL THE ABOVE No Inst. Exists No Inst. Exfsts CONDENSER AIR REMOVAL SYS.EXH.

RAD-6417 Afr E5ector Condenser Exh.

lr Ejector Condenser Flov 10 to 10

~t/CC 10 to 10

~Cf/CC N/h Note 8 N/A N/A Note 12 SAS Yes Yes No Inst. Exists E5 COMMON VENT RAD-6304 Vent Stack H.R. Rad. Monitor E

FT-6584 Vent Stack - Flov VKHP FROM STKAH GENERATOR SAFETY RELIEF VALVE RAD-6426 Stean Line Rad. Honttor 10 to 10

/A.Ct/CC 0 - 150,000 cfa lo to 10 5 p.CI/CC IO-'O'f 5CC 0 - 1107.

Design Flov 10 to lo p.Ct/CC NIA N/A N/A Note 8 Note 8 Note 8 N/A N/A N/A N/A N/A Note 12 Note 12 Mott 12 SAS SAS SAS Yes Yes Yes Yes Yes Yes cto sxxo x Ksl

PARAMETER LISTING SUIRQRY SHEETS UNIT 3 TURKEY POItiT 12/83 Sheet 44 of 46 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY CATE-INSTRUMENTRANGE EXISTING REQUIRED Q.A.

REQUIRE.

MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUAUFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION CR TSC EOF

- SCHEDULEI JUSTIFICATION Ey RD-14 RD-11 PARTICULATES & NALOCENS ALL IDENTIFIED PIANT RELEASE POINTS Vent Stack htnos.

Conte lnnent htnos.

E 3

0-10 CPS 3

>> p Cl/CC to 10 P Cl/CC N/A N/A N/A N/A Note 12 SAS Yes Yes RD 12 Containment Atnos.

10 H.

M.D.

So.Dade HETEOROLOCY - MIND DIRECTION 4 SPEED ESTIMATE OF ATMOSPHERIC STABILITY Meteorology 10 Meter Mind Direct ton 0- 540 0

360 N/h N/A N/h N/A Note 12 SAS Yes Yes 10 M.

M.D.

Turkey Point Meteorology 10 Heter Mind Direction 60 H.

'M.D.

So.Dade Meteorology 60 Meter Mind Dlrectlon 10 N.

M,S So.Dade Meteorology 10 Heter Mind Speed 0

120 HPN 0 - 50 MPN 10 H.

M.S.

Turkey Po tnt 60 H.

M.S, So.bade Meteorology 10 Heter Mind Speed Meteorology 60 Heter Mind Speed can.ssxo a s M

PARAHETER LISTING SmhRY SHEETS UNI'T 3 TURKEY POINT 12/83 Sheet ~4 of~

ITEM TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

GORY INSTRUMENTRANGE EXISTING

~

REQUIRED REQUIRE-ENVIRONMENTAL Q.A.

QUALIFICATION SEISMIC QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULEI JUSTIFICATION Delta T

'A'.D.

De IC'a T

'B'.D.

10 H.

SIBma Theta T.P.

HEYEOROLOCY MIND DIRECTION 4 SPEED ESTIHATE OF AIHOSPNERI C STABILITY (Cont Inue 4)

Estimate of Atmos. Scability Estimate of Atmos. Stability Estimate of Atmos. Stability Temp.

'B'.D.

Estimate of Atmos. Stability Temp.'A'stimate of Atmos. Stability S.D.

-5 to +5 F

-5 to +5 F 0 - looo 0 - 120 F 0 - 120 F BASED ON VERTI CAL TEHPERATURE DIPFERENCE FROH PRIHARY HETEO-ROLOCICAL SY 5oC TO leoC

(-Soc TO IB F)

AND + 0 15oC ACCURACY PIR 50.

HETER INIERVALS

(+ 0.3 F ACCU-RACY PER 164 FOOT INZERVALS)

OR ANALOCOUS RANCE FOR ALTERNATIVE STABILITf ESTIHATES, N/A N/A N/A QTIB ~

N/A

'emp

'Bs Temp she Note 12 SAS

10. H.

Dev Pt ~

S.D.

60 H.

Der Pt.

S.D.

Estimate of Atmos. Stability Estimate of Atmos. Stability 0 - 120 F 0 -120F N/A Rainfall Escimate of Atmos. Stability S.D.

0 - I" Direct Solar S.D.

Total Solar S.D.

Estimate of Atmos. Stability Estimate of Atmos. Stability cpo sxoo x 9>sl

PARAMETER LISTING SWARY SHEETS UNIT 3 TURKEY POINt 12/83 Sheet 46 OI 46 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN.

DANCE POWER SUPPLY CR TSC EOF DISI LAY LOCATION SCHEDULE/

JUSTIFICATION AE-6373 Ctat. Air - Isotopic Analysis CaIaea Spectrua ACCIDENT SAMPLING CAPABILITY PRIMARY COOIANI'ND SUMP AK-6372 RCS Activity Cross CPS 10 - 10 CPS 10 - 10 CPS 10 ~Ct/al to 10 Ct/al Isotopic Analysis N/A N/A N/A N/A N/A N/A Note 15 SAS Yes Yesfl AE-6424 AK-6455 AE 6453 AE-6456 AE-6454 Boron Analyzer RCS Soluble Boron Concentration RCS Chloride Analysts of Prtaary Coolant Dissolved H9 Analysts of Prtasry Coolant Dissolved 02 Analysts of Priaary Coolant RCS pH Analysis of Priaery Coolant 0

6000 ppa 0 - 20 ppa 100K of Vol.

0 20 ppII I - 13 ph 0

6000 ppa 0 - 20 ppa 0 to 2000 CC/IIB 0-20ppa I - 13 ph SEE ITEN B3 N/A N/h N/h Note 15 SAS Yes Yes AK-63078 Ctat.

H2 Concentration Ch.

B None Ctat.

02 AE-6373 Ctat. Atr Ceane Spectrua CONTAINMENI'IR AE-6307A Ctat.

H2 Concentration Ch. A 0 - 10X end 0-20X 0 - IOX and 0

20X Crab Seaple 10 - 10 CPS 0 - 10 Vol. 'X 0- IOVol. X 0 - 30 Vol. 7.

Isotopic Analysis SEE ITEM C12 SEE ITEM C12 SKE ITEN C12 No Inst. Exists cIn Igloo ~ a asl

SECTION VI LIST OP SYSTEMS REQUIRING ADDITIONS, MODIPICATIONS OR ANALYSIS

The following is a list of the Turkey Point Unit P3 instrument system, which as a result of this evaluation, r equires addition, modification or analysis.

Item B-1 Neutron Flux Two additional redundant safety grade loops for full range neutron flux indication in the control room and in the hot shutdown panel will be provied for long ter m accident monitoring capability and to satisfy the requirements of Appendix R (10CFR50) regarding shutdown from outside the control room.

This system will be completely independent of the existing neutron flux detectors and willbe operational dur ing the 1985 refueling outage.

2.

Item B-15 Containment Isolation Valve Position Indication.

Safety grade limit switches willbe provided for the following containment isolation valves during the 1985 refueling outage:

CV-4658 Ad(B CV-4668 Ad(B CV<659 Ad(B CV-2903 CV-2904 CV-2905 CV-2906 CV-2907 CV-2908 CV-2810 CV-2812 CV-2814 FCV<78 FCV-479 FCV-488 FCV-489 FCV-498 FCV-499 3.

Item B-15 Containment Isolation Valve Position Indication.

Safety gr ade limit switches have been installed for the following containment isolation valves.

Wiring to SAS willbe provided.

CV-2816 CV-2831 CV-2817 CV-2832 CV-2818 CV-2833

4.

Item D-13 Pressurizer Heater Status Three ammeters will be added to the control room and indication in SAS/TSC and EOF for the Pressurizer Heater Status by the end of the 1985 r efueling outage.

5.

6.

7.

Item D-3 Accumulator Tank Level The following transmitters will be replaced by qualified Rosemount Transmitters during the 1985 refueling outage.

LT-920 LT-922 LT-924 LT-926 LT-928 LT-830 Item A-4 RWST Level Two new safety grade completely independent level indication loops willbe provided for RWST level indication in the control room, SAS, TSC and EOF by the 1985 refueling outage.

LT<583 A 8( B ICCS qualification r eport willbe available by January 31, 1984.

SECTION VII REFERENCES

REFERENCES Regulatory Guide 1.97, Rev. 3 10 CFR 50.49 Regulatory Guide 1.89 Regulator y Guide 1.100 NUREG 0737, Supplement 1

NUREG 0588 IEEE-323, 1974 IEEE-344, 1975

SECTION VIII CONCLUSIONS

CONCLUSIONS Based on the information presented in this report, Turkey Point Plant Unit 43 willconform with the requirements of Reg. Guide 1.97, Rev.

3 by the end of 1985 refueling outage.

For some instrumentation which does not fully comply with the requirement of Reg. Guide 1.97, Rev. 3, a justification has been provided (Section V).

TURKEYPOINT PLANT UNIT NO. 4 ENGINEERING EVALUATION OF INSTRUMENTATIONSYSTEM FOR REGULATORY GUIDE 1.97, REV. 3 DATE: September 1983

SECTION III.

IV.

V.

VI.

VII.

VIIL TABLE OF CONTENTS DESCRIPTION Regulatory Guide 1.97, Rev. 3 Requirements Evaluation Cr iteria iVIethodology of Equipment Evaluation Type A Variable List of Parameters Parameter Listing Summary Sheets List of Systems Requiring Additions, iVIodifications or Analysis Refer ences Conclusions PAGE NO.

2i 3 4,5 7,8 10

SECTION I REGULATORY GUIDE 1.9Z, REV. 3 REQUIREMENTS

Regulatory Guide 1.97, Rev. 3, titled "Instrumentation for-bight-Water-Cooled Nuclear Power Plants to Assess Plant and Environs 6

'.ions During and'ollowing an Accident", divides all instrumentation usa.cf for Post Accident Monitoring into five functional types as shown below:

Type A Variables:

those variables to be monitored that provide the primary information required to permit the control room operator to take specific manually controlled actions for which no automatic control is provided and that are required for safety systems to accomplish their safety function for design basis accident events.

Primary information is information that is essential for the direct accomplishment of the specified safety functions; it does not include those variables that are associated with contingency actions that may also be identified in written procedures.

Type B Variables: those variables that provide information to indicate whether plant safety functions are being accomplished.

Plant safety functions are (1) reactivity control, (2) core

cooling, (3) maintaining reactor coolant system

.integrity, and (4) maintaining containment integrity (including radioactive effluent control).

Type C Variables:

those variables that provide information to indicate the potential for being breached or the actual breach of the barriers to fission product releases.

The barriers are (1) fuel cladding, (2) primary coolant pressure boundary, and (3) containment.

Type D Variables:

those variables that provide information to indicate the operation of individual safety systems and other systems important to safety.

These variables are to help the operator make appropriate decisions in using the individual systems important to safety in mitigating the consequences of an accident; Type H Variables:

those variables to be monitored as required for use in determining the magnitude of the release of radioactive materials and continually assessing such r eleases.

Post Accident Monitoring Instrumentation is divided into three categories based on the degree of equipment qualification requirements, redundancy, power sour ces, channel availability, quality assurance, and display and recording requirements.

In general, Category 1 provides for fullqualification, redundancy, and continuous real-time display and requires onwite (standby) power.

Category 2 provides for qualification but is less stringent in that it does not (of itself) include seismic qualification, redundancy, or continuous display and r equires only a

high-reliability power source (not necessarily standby power).

Category 3 is the least stringent.

It provides for high-quality commercial grade equipment that requires only offsite power.

SECTION II EVALUATIONCRITERIA

4

Our review of RG 1.97, Rev. 3 requirements applicable to operating plants shows that the'requirements of this guide cover the requirements of 10 CFR 50.49 and NUREG 0737 and its subsequent clat ification and generic letter 82-33.

The following is the evaluation criteria used in this report for the three different categories as defined in the Regualtory Guide 1.97, Rev. 3, Table 1.

1.

ENVIRONMENTAL UALIFICATIONCRITERIA a.

Cate or 1 Instrumentation (a).

Instrumentation located in harsh environment should comply with 10 CFR 50.49 requirements and NUREG 0588 Category 1

(IEEE-323, 1974).

(b).

Instrumentation located in mild environments do not have to be up-graded if they withstand their service location conditions under normal and emergency conditions.

b.

Cate or 2 Instrumentation (a).

For safety related instrumentation, follow the same criteria used for category 1 instrumentation.

(b).

Non-nuclear safety related instrumentation located in harsh environment has to be qualified per NUREG 0588 category 1.

(c).

Instrumentation located in mild environment should follow the same criteria used for category 1 instrumentation.

c.

Cate or 3 Instrumentation Non-nuclear safety related instrumentation has to withstand its service location conditions.

2.

SEISMIC UALIFICATIONCRITERIA Category 1 and Safety Related Category 2 instrumentation:

The equipment shall comply with IEEE-344, 1975.

(Reg.

Guide 1.100)

Category 3 and non safety related related category 2 instr umentation:

No specific provision required.

3.

REDUNDANCE Only category 1

instr umentation should be provided with redundant or diverse channels, electrically independent, and physically separated from each other, and from nonwafety equipment, in accordance with Reg. Guide 1.75 "Physical independence'of electric systems",

up to and including any isolation device.

Category 2

and 3

instrumentation do not requir e redundancy.

4.

POWER SOURCES a.

~Cate or 1

Instrumentation to be supplied from 120 VAC uninterruptible power

source, or from 120 VAC Offsite Power supply, backed up'y an Emergency Diesel Generator if momentary interruption of power is acceptable.

b.

~Cate or 2

Instrumentation to be supplied from high reliability power source which can be either from:

1.

2.

3.

4.

120 VAC uninterruptible, or 120 VAC Offsite Power backed by an Emergency Diesel Generator, or 125 VDC safety-related battery, or 125 VDC non-safety related battery e.

~Cate or 3

No specific provisions required.

5.

UALITY ASSURANCE - Qualified equipment (category 1

and safety related category 2

should comply with the Regulatory Guides listed in Table 1 of Reg. Guide 1.97 Rev.3.

6.

DISPLAY AND RECORDING Category 1 Instrumentation should be displayed on a real-time 'display.

The indicator may be on a dial, digital display, CRT or strip chart recorder.

Recording of instrumentation readout should be provided for at least one redundant channeL Where dedicated strip chart recorder is not provided, recording should be updated and stored in computer memory and displayed on demand.

Category 2 Instrumentation should be displayed on an individual instrument or it may be processed for display on demand.

Signal from effluent radioactivity and area monitors should be recorded.

Category 3 Instrumentation.

(Same as Category 2).

Signal from effluent radioactivity, area and meteorology monitors should be recorded.

SECTION III METHODOLOGY OF EQUIP MENT EVALUATION

We have evaluated existing system arrangements and identified components for variables Types A thru E and their conformance to Reg.

Guide 1.97, Rev.

3

'equirements applicable to existing plant.

Based on our interpretation of Reg.

Guide 1.97, Rev. 3 all Post Accident Monitoring instrumentation can be divided into thr ee groups as shown below:

1.

ORIGINALSAFETY RELATED INSTRUMENTATION The original, safety related instruments located in harsh environment has been or will be replaced by qualified instruments per our commitment in response to bulletin 79< lB, 10CFR 50.49 or by this report.

The instr uments located in mild environment do not require specific qualification until revision of the Regulatory Guide 1.89 is published.

The original safety related instrumentation generally comply with the seismic qualification program which was the basis for plant licensing.

2.

ADDED OR REPLACED SAFETY RELATED INSTRUCT(IENTATION The added or replaced safety related instrumentaton generally comply with the requirements of 10 CFR 50.49 or the latest IEEE standards.

3.

NON SAFETY INSTRUMENTATION These instruments are high quality commercial grade equipment that require no specific qualification, however if the instrument is category 2

located in harsh environment, should be environmentally qualified.

Once the evaluation of all the instrumentation has been completed, a schedule for the implementation of the required modification to comply with the Reg.

Guide requirements has been included.

Section V of this report is the Parameter Listing Summary Sheets which includes all the plant instrumentation by tag numbers, grouped in the same order as the Reg. Guide 1.97, by type and categories.

The listing summarizes all the required information to per form the evalution and the results of the evaluation are shown on the column justification/schedule.

If this column is

blank, it means that the instrument complies with the requirements of the Reg. Guide 1.97.

The Parameter Listing Summmary Sheets provide the following information:

Item, tag number, variable description, type and category, instrument existing and required

ranges, Q.

A.

requirements, environmental and seismic qualification, redundance, power

supply, display
location, schedule for implementation or justifications.

Variable description

column, described the variable as listed in the Reg.

Guide 1.97, Rev. 3.

t The tag number column, lists all the sensors, indicators, displays and recorders associated with variable described.

In the column "Display Locations, Control Room C.R.", Yes, means that the indicator is located in the control room; SAS means that the data is available in SAS.

In the Column "Display Location TSC and EOP", Yes, means that the data is available on the computer display in the TSC and EOP.

Finally, section VI, lists all systems requiring modification, additions or analysis to comply with the Regulatory requirements.

0

SECTION IV TYPE A VARIABLELIST OP PARAMETERS

The type A variable list of parameters, the basis for which is given in Reg. 1.97, Rev.

3, was established.

The following Emergency Operational Procedures (EOPS) were reviewed:

a.

b.

Co d.

Immediate Action and Diagnostics (E-1)

Loss of Reactor Coolant (E-1)

Loss of Secondary Coolant (E-2)

Steam Generator Tube Rupture (E-3)

As a result of these reviews the following parameters were designated as Type A variables:

1.

2:

3.'.

5.

Pressurizer Pressure RCS Hot Leg Temperature RCS Cold Leg Temperatur e Steam Generator Level Narrow Range Refueling Water Storage Tank Level Pressurizer Pressure and RCS Hot and Cold leg temperatures were designed type A variables due to their use as inputs for calculating margin to subcooling.

The Subcooling margin will be displayed in. the two channels "Inadequate Core Cooling System" (ICCS) displays in the Control Room.

Specifically the operator actions pertinent to subcooled margin concern are the following:

a)

Maintain the RCS hot leg temperature and pressurizer pressure

stable, using Auxiliary Feedwater, steam dump, or initiating Safety Injecton as indicated in the Emergency Operating Procedures, when the pressurizer pressure drops below 1723 psig or the subcooling margin dr ops below 30oF.

b)

If voiding in the RCS should occur, subcooled margin no longer exists, the operator must ensure that the R.C. pumps ar e shut off.

The Steam Generator Narrow Range Level is designed type A variable due to its use to deter mine the Auxiliary Feedwater initiation to maintain the Steam Generator Level above 15% in the narrow range span during loss of Secondary Coolant and for Steam Generator Tube Rupture Events.

The RWST Level is designed type A variable due to its use in determining the cold leg recirculation mode switchover or R.C. pump stop during Loss of Reactor Coolant Accident (LOCA).

SECTION V PARAMETER LISTING

SUMMARY

SHEETS

12/83 Sheet 1 of 2 UNIT S NOTES For Ta No:

(LS) ~ Limit switch associated with valve For Environmental Column:

1.

Comply with 10 CFR 50-49 and NUREG 0588 Category I.

2.

Will comply with 10 CFR 50-49 and NUREG 0588 Category I.

3.

Comply with 10 CFR 50-49 and NUREG 0588 Category II.

4.

Will comply with 10 CFR 50-49 and NUREG 0588 Category II.

5.

Original equipment environmentally qualified per 79-01B Report.

6.

Non-Safety-Related Category 2 instruments located in harsh environment "comply with 10 CFR 50-49 and NUREG 0588".

7.

Non-Safety-Related Category 2 instruments located in harsh environment "will comply with 10 CFR 50-49 and NUREG 0588".

8.

Instruments located in mild environment (all categories)

"No specific qualification required".

For Seismic ualifi'cation Column:

9.

"Original Equipment":

comply with the seismic qualification program which was the basis for plant licensing.

10.

New and Re laced E ui ment:

Comply with Reg.

Guide 1.100.

11.

New and Re laced E ui ment:

Will comply with Reg.

Guide 1.100.

For Power Su 1

Column:

Power source is identified as:

12.

Class 1E, 120 VAC uninterruptible power supply (inverters).

13.

Class 1E, 120 VAC offsite power backed up by the Emergency Diesel Generator.

14.

Class lE, 125 DC safety related battery.

15.

Non-Class 1E, 120 VAC offsite power (interruptibl'e).

16.

Class lE, 4.160 kV AC offsite power with no back up.

17.

Class 1E, 480 Volt AC offsite power with no back up.

18.

No electrical connection.

UNIT 4 12/83 Sheet 2 of 2 For Schedule/Justification Column 19.

Qualification Report for the ICCS will be issued by Combustion Engineering by January 31, 1984.

20.

Single Channel SMM is now in operation.

After next refueling outage, the SMM will be displayed in the two-channel ICCS.

21.

To be replaced during next refueling outage.

22.

To be replaced during the 1985 refueling outage.

23.

A non-safety related steam generator feedwater level "Wide Range" instrument loop with readout in the main control boards also available.

24.

Category 1 redundancy does not apply because a secondary containment.

isolation valve is generally available from each line penetrating the containment.

25.

Range does not comply, however fixed area radiation monitors located at areas important to safety will not be useful to an operator carrying a portable high range area detector on the trip to, at, or from the area important to safety.

GENERAL NOTES:

26.

Recording will be stored and displayed continually on demand in SAS.

27.

SAS Implementation Plan will be submitted by May 1, 1984.

28.

Only narrow range level indication is required.

Upon loss of narrow range level for a period of up to four (4) hours the unit should be placed in hot shutdown within seven (7) hours, and in cold shutdown within the following thirty (30) hours (Technical Specification 3.0).

PARANETER L IDDIARY SHEETS UNIT Y POIÃY Sheet I

of 46 ITEM TAG NO.

VARIASLE DESCRIPTION TYPE ATE.

GORY INSTRUMENTRANGE EXISTING REQUIRED Q.A.

REQUIRE-MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

POWER DANCE SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULEI JUSTIFICATION PIAMF SPECIFIC Al PT-404 RCS PRFSSURE RCS Prcssure 0-3250 PSIC Plant Specific Coaply Note I Note 10 PY-406 Note I SAS Yes Yes PT-406 RCS Pressure 0 3250 PSIC Coap ly Note 1 Note 10 PT-404 SAS Ycs ICCS A ICCS B Dtsplay A Dfsplay B 0-3250 PSIC 0 3250 PSIC Mill Coaply

'Mill Coap ly Note 2 Note 2 Note 11 Note 11 ICCS B ICOS A Yes Ycs Note 19 Note 19 A2 RCS HOT IZC MYR TDIFERATURE TE-413A TE-4138 TE 423A TE-423B TE-433A TE 433B TR 413 ICCS A ICCS B

RCS Hot Leg Mtr. Teap.

Loop A RCS Hot Leg Mcr. Teap.

Loop A RCS Hot Leg 'Mtr. Tecp.

Loop B

RCS Hot Leg Mtr. Teap.

Loop B RCS Hoc Lcg Mtr. Teap.

Loop C RCS Hot Leg Mtr. Teap.

Loop C

'RCS Hot Leg 'Mcr. Trap.

Recorder Loop A ~ B, C Display A Display B

0-750 P

Plant SPecf ffc Coaply Comply

'Mf11 Coaply Mill Coaply Note 1

Note 8 Note 2 Note 2 Note 10 Note 10 Note 11 Note 11 TE-413B Note I TE-413A TE-423B TE-423A TE-433B TE-433A ICCS B ICCS A SAS Yes Yes Yes Ycs

~s Note 19 Note 19 cso

~ xKQ < s4)

PARANETKR L RY SHEETS'NIT POINF Sheet 2

Of 46 ITEM TAG NO.

VARIABLE DESCRIPTION PE GO ATE.

EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN-POWER DANCE SUPPLY DISPLAY LOCATION TSC EOF CR SCHEDULE/

JUSTIFICATION PIANF SPECIFIC (Continaed)

A3 TE-410A TE 410B TE 420h TE-4208 TE-430h TE 4308 RCS COLD IEC MTR TEMPERATURE RCS Cold Lcg Mtr. Temp.

Loop h RCS Cold Lcg Mtr. Temp.

Loop A RCS Cold Leg Mtr. Temp.

Loop B RCS Cold Leg Mtr. Temp.

Loop 8 RCS Cold Leg Mtr. Temp.

Loop C RCS Cold Leg Mtr. Temp.

Loop C 0-750 P

Plant Spectflc Cockily Note 1 Note 10 TE-410B Note 12 SAS TE-410A TE-4208 TE-420A TE-4308 TE-430A Yes Ycs TR-410 ICCS A ICCS B RCS Cold Lcg Mtr. Temp.

Recorder Loop A, B, C

Display h Display 8 Coop ly Mill Comply

'Mill Comply Note 8 Note 2 Note 2 Note 10 Note 11 Note 11 N/A ICCS 8 ICCS A Ycs Yes Yes Note 19 Note 19 RUST LEVEL

'T-6583A RMST Ch.

A Level LI-6583h RMST Ch. h Level Ind.

LT 65838 RMST Ch.

B Level LI-6583B RMST Ch. 8 Level Ind 0-330,000 Cal.

Plant Spe<<lflc 0-330,000 Cal.

0-330,000 Cal.

0-330,000 Gal.

'MIII Comply Note 2 Note 8 Note 2 Note 8 Note 11 LI-65838 LT 6583h LI-6583A Yes SAS Yes LT-65838 Note 12 SAS Yes Yes Yes Yes Note 21 Note 21 Note 21 Note 21

PARAMETER UNARY SNEEYS UNiT Y POINI 3

OI 46 ITEM TAG NO.

A5 VARIABLE DESCRIPTION PIANI'PECIFIC (Continued)

S.C.

LEVEL NARR(M RANCE TYPE GORY'TE INSTRUMENTRANGE EXISTING

'EQUIRED REQUIRE ENVIRO'ENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN POWER DANCE.

SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULEI JUSTIFICATION LT 474 LI 474 LT-415 LI-475 S.C.

'A>> Lvl. Ch. I Narrow Range S.C. 'A'vl. Ch. I Narrov Range Ind.

S.C. 'A'vi. Ch. II Narrov Range S.C. 'A'vl. Ch. II Narzov Range Ind.

30.1" to 138.22" plant Specpffc 0

100X 30.1" to 138.22" 0 - 100X Coal ly Note I Note 8 Note 1 Note 8 Note 10 Note 9 Note 10 Note 9 LT 475 LT-476 LI 475 LI 476 LT 474 LT&76 LI 414 Ll<76 Nate 12 Yes

~ s Ycs Yes Yes LT-476 LI&76 IR-478 I.T-484 I.I-484 LT 485 LI-485 LT 486 LI-486 IR 488 8:C. 'A'vl. Ch. III Narrov Range S.C. 'A'vl Ch. III Narrov Range Ind.

S.C. 'A'vl. Ch. I, II, III Narrow Range Recorder S.C. '8'vl. Ch. I Narrav Range S.C. '8'vl. Ch. I.

Narrov Range Ind.

S.C. '8'vl. Ch. II Narrov Range S.C. '8'vl. Ch. II Narrow Range Ind.

S.C. '8'vl. Ch. III Narrov Range S.C. '8'vl. Ch. III Narrov Range Ind.

S.C. 'B'vl. Ch. I, 11, 111 Narrow Range Recorder 30 1" to 138.22" 0 - IOOX 0 - IOOX 30.1v to 138 22v 0 - 100X 30.1" to 138.22" 0 - IOOX 30.V'o 138.22" 0 - 100X 0 - 100X Note I Note 8 Note 8 Note 1

Note 8 Note I Note 8 Note I Note 8 Note 8 Note 10 Note 10 Note 10 Note 10 Note 9 Note 10 Note 9 Note 10 Note 10 Note 10 LT 474 LT 475 LI 474 LI 475 N/A LT-485 LT-486 LI-485 LI<86 LT-484 LT-486 LI 4S4 LI486 LT-484 LT<85 LI-484 LI-485 N/A Yes Ycs Yes Ycs Ycs Ycs Yes Ycs Ycs Yes Yes Yes Yes aro soooo.x os>

PARAHEIER LIS UNIT 4 RY SHEerS POINT Sheet 4

of 46 ITEM TAG NO.

VARIABLE DESCRIPTION GORY CATE.

EXISTING REQUIRED INSTRUMENTRANGE ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION EOF CR TSC SCHEDULEI JUSTIFICATION LT-494 LI-494 LT 495 LI-495 LT<96 LI 496 LR 498 S.C.

IZVEL NARR(Xt RANCE (Conttnued)

S C eCl Lvl. Ch. I Narrov Range S.C. 'C'vl. Ch. I Narrov Range Ind.

S.C. 'C'vi. Ch. II Narrov Range S.C. 'C'vl. Ch. II Narrov Range Ind.

S.C.

'Cl Lvl. Ch. III Narrov Range S.C. 'C'vl. Ch. III Narrov Range Ind.

S.C. 'C'vl. Ch. I> II, III Narrov Range Recorder A'

30.1" to 138.22" Plant Specfftc 0

100E 30.1" to 138.22" 0 -

ICONS 30.1" to 138.22" 0 - 100K 0 - 1004 Cosy ly Note I Note 8 Note 1

Note 8 Note 1

Note 8 Note 8 Note 10 Note 9 Note 10 Note 9 Note 10 Note 10 Note 10 LT-495 LT-496 LI-495 LI 496 LT-494 LT-496 LI-494 LI 496 LT-494 LT-495 LI-494 LI-495 NIA Note I SAS Yes Yes Yes Yes Yes Yes Yes Yes Yes cpo ssooo

~ x 9(ss

PARAMETER L UNIT 4 UNNARY SHEETS POINT ITEM TAG NQ.

VARIASLE DESCRIPTION GORY CATE.

EXISTING REQUIRED INSTRUMENTRANGE REQUIRE.

Q.A.

MENT,QUALIFICATION SEISMIC QUALIFICATION REDUN-POWER DANCE SUPPLY DISPLAY LOCATION EOF CR TSC SCHEOULEI JUSTIFICATION N-35 NI 35 B N-36 NI 368 REACTIVITY CONTROL NEUTRON FLUX Neutron Flux (Inceraedface Range)

Neutron Flux (Internedfate Range) Indicator Neutron P lux (Incernediate Range)

Neutron Flux (lnteraedfate Range) Indtcetoc'\\

8' 10 11 co 10 3

ANP 10 co 1002 Full Pover NfII

" Coup ly Note 2 I

Note 8 Note 2 Note 8 Note ll N-36 NI 36B N 35 NI-35B Note I SAS Tee Yes SAS Tes Yes Tes Note 22 82 70CR 71CR 72CR REACTIVITY CotrIROL CONTROL ROD POSITION Control Rod Bank

'A'od Bottoa Svitch Control Rod Bank

'B'od Boctos Switch Control Rod Bank

'C'od Boctoa Switch Control Rod Bank

'D'o4 Bottoa Svttch 8

3 Full ln Or Not Full In Full In Or Not Full In N/A N/A NIA NIA Note 14 SAS Yes 75CR Control Rod Bank lhl Ro4 Bottoa Svfcch Concrol Rod Bank

'8'od Bottoa Switch 83 REACTIVITY CONTROL RCS SOLUBLE BORON CONCENTRATION AE-6424 Boron hnalycer RCS Soluble Boton Concencratfon B

3 0-6000 PPII 0 6000 PPII N/A NIA N/h N/A Note 15 SAS Yes Yes CAD SXOO X S Sl

PARANETER C SUIRIARY SHEETS UNIT TURKEY POINT Sheet 4

oI~4 ITEM TAG NO.

VARIABLE DESCRIPTION GORY CATE.

EXISTING REQUIREO INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REOUN POWER DANCE SUPPLY DISPLAY LOCATION TSC EOF CR SCHEOULEI JUSTIFICATION TE 410A TE-410B TE 420A TE 420B TE-430B TR 410 ICCS A ICOS B REACTIVITY CONYROL RCS COLD LEC MIR. TEMP ~

RCS Cold Leg Mcr. Tea@.

Loop 'A~

RCS Cold Leg 'Mtr. Teap.

Loop 'Ai RCS Cold Leg Mtr. Teap.

Loop

'B'CS Cold Leg Mcr. Tcap.

Loop

'b'CS Cold Leg Mtr. Taap.

Loop

'C'CS Cold Leg Mtr. Teop.

Loop

'C'CS Cold Leg Mcr. Tee@.

Recorder Loop A, B, C Dtaplap

>As Dfepley 'B' 750 P

50 - 400 P SEE ITEN A3 BS TE 413A TE-413B TE 423A TE-423B CORE COOLINC RCS HOI'EC MTR. TEMP.

RCS Hot Leg Mtr. Temp.

Ae RCS Hot Leg Mtr. Teap.

Loop

'A'CS Hot Leg Mtr. Teep.

Loop

'B'CS Not Leg Mcr. Teop.

~ 'B'

- 250 P

50 - 700 P SEE ITEN A2 cpo 44444 ~ x 9 41

PARAMETER L UNIT 4 UMMARY SHEETS POINT Sheet 7 of~

ITEM TAG NO.

S5 VARIABLE DESCRIPTION CORE COOLINC RCS HOT LEC dddd. Tddd.

(d ll d)

TYPE ATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE REQUIRE ENVIRONMENTAL Q.A.

QUALIFICATION SEISMIC QUALIFICATION REDUN-POWER DANCE SUPPLY DISPLAY LOCATION TSC EOF SCHEDULEI JUSTIFICATION TE 4334 TE&33B TR-413 ICCS A ICCS b RCS Hot Leg 'Mtr. TeedP.

~

'C'CS Hot Leg Mtr. Teedp.

Loop

'C'ecorder Loop A, B, C Dleplay

'h'leplaytbo 0 - 750 j 50 - 700 P SEE ITEM A2 B6 TE<10b TE-420A TE-420B TE-430A CORE COOLINC RCS COLO IEC MIN. TEMP.

RCS Cold Leg Mtr. Teedp.

Loop

'h'CS Cold Leg Mtr. Teedp.

Loop

'h'CS Cold Leg Mtc'. Teop.

Loop

'B'CS Cold Leg Mtr. Teedp.

Loop

'B'CS Cold Leg IItr. Teop.

~ 'c'

- 750 P 50 700 P

SEE ITEM A3 TE-430S RCS Cold loop 'C'eg 'Mt'r-Teedp.

TR 410 ICCS A ICCS B Recorder Dleplay

'h'leplay

'B'oop A, B, C ceo-exKxl~ a alee

ITEM TAG NO.

VARIABLE DESCRIPTION ATE.

GORY PARAHETER UNIT EXISTING REQUIRED INSTRUMENTRANGE SURIARY SHEETS URKEY POINT ENVIR0 NMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

POWER DANCE SUPPLY DISPLAY LOCATION EOF CR TSC SCHEDULE/

JUSTIFICATION 87 pf-404 CORE COOLINC RCS PRESSURE RCS Pressure 8'

- 3250 PSIC 0

3000 PSIC SEE ITEN hl PT-406 RCS Pressure ICCS A Display

'A'CCS 8

Display

'8'8 TE-IE Thru TE-51E ICOS A ICCS 8 CORE COOLINC CORE EXIT TEMP.

Core Exit Tcopcrature Display sh e Display'8'00 2300 P

200 - 2300 P N/A N/A N/A N/h Note 12 SAS Yes Yes Yes 89 ICCS RVL-A (HJTC) coRE cooLIHO coolhÃr INVENTORY Reactor Vessel 'Mtr. Lvl.

Ch.'A'op of Core to Top of Vessel Bottou of Hot Leg to Top of Vessel Coup 1y Note 2

Note 11 RVL 8 Note 12 SAS Yes Yes Note 19 ICCS RVL 8 (tuTC)

Reactor Vessel Mtr. Lvl.

Ch.'8'oup ly RVL-A SAS Yes Yes Note 19 ICCS A

~

Display

'h'CCS 8

Display'8'ill Cocply Mill Coup ly ICCS 8 ICCS A Yes Yes Note 19 Note 19

0

PARAMETER LI UNIT 4 'I MMARY SHEETS POINT Sheet 9 CI~

ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY CATE.

EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE-MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REOUN.

OANCE POWER SUPPLY CR TSC EOF DISPLAY LOCATION SCHEOULEI JUSTIFICATION B10 SMY-A CORE COOLING DECREES OF SUSCOOLINC RCS Temp. Saturation Harbin Ch. 'h' 2

-2100 to 700 F 200 F Subcooli to 35 F Super-Coup ly Note 1

Note 10 SHY-B Note 12 ICCS Yes SAS Yes Note 20 SMY-B RCS Temp. Saturation Harbin Ch

<be Comply Note 1

Note 10 Note 12 ICCS Ycs SAS Ycs Note 20 Bll FI-404 MAINPAIMINCRx COOIAÃl'YS INTEGRITY RCS PRESSURE RCS Pressure 0 - 3230 PSIC 0 - 3000 PSIC SEE ITEM Al FT-406 RCS Pressure TCCS A ICSS b Display

'A'isplay

'B'12 LT-6308A LI-6308A IR 6308A IT 6308b MAIMfhININCRx COOIANI'YS INTECRITY CIMP SUMP WIR.IVI.

Cmst. S~ Wtr. Lvl.

Ctnt.

Sump Wtr. Lvl. Ind.

Ctmt.

Sump Iltr. Lvl.

Ctmt.

Sump Iltr. Lvl.

b 2

-18'Ft. El. to El. 141-0'I 0

369" 0

369"

-18'Ft. El. to Ei. 14'"

Narrow Ranbe (S~)

Comply Note 1

Note 8 Note 8 Note 1

Note 10 LT-63088 LI-63088 LR-63088 LT-6308A Note 12 SAS Yes Ycs Ycs SAS Ycs Yes Yes LI-63088 LR-6308b Ctmt.

Sump Wtr. Ivl. Iud ~

Ctmt.

Sump Wtr. Lvl.

0 - 369" 0 - 369" Note 8 Note 8 LI-6308A LR-6308A Ycs Yes Gpo lxxo x esl

PARANETER L UNIT 4 SU)e)ART SHEETS YPOINI'heet of ITEM TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

GORY INSTRUMENTRANGE EXISTING

'EQUIRED QA.

REQUIRE.

MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN-POWER DANCE SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULE/

JUSTIFICATION 813 NAINIAWNINORx COOIANI SYS INIECRIIY CI)II'. SUNP MTR. LVL LT-63094 Ctnt. 'Mtr. Ivl.

El. 14'-0" to El. 22'-0" Mldo Range lant Spcciftc)

Coop 1y Note I Note 10 LT 63098 Note 12 SAS Yes Yes LI-6309A Ctaat. 'Mtr. Lvl. Ind.

LR 6309A Ctnt. Mtr. Lvl.

LT-63098 Ctnt. Mtr. Lvl.

LI-63098 Ctaat. Mtr. Lvl. Ind.

LR 6309b Ctnt. Mtr. Lvl.

397" to 487" 397" to 487" El. 14'-0" to El. 22'"

397" to 487" 397" to 487" Note 8 Note 8 Note 1

Note 8 Note 8 LI 6309B LR-63098 LT 6309A LI-6309A LR 6309A 4,

Ycs Yes Ycs Yes Yes Ycs 814 NAINTAININORx COO)ANI'YS.

INIECRITY-CINI PRESSURE PT-63064 CBC'. Press.

'Mlde Range B

0 - 180 PSIC 0 PSIC to Design Pressure Coaaply Note 1

Note 10 PT-63068 Note 12 SAS Yes Ycs PI-6306A Ctaat. Press.

Mldc Range Ind.

PR-63064 Ctaat. Press.

Hide Range PT-6306B Ctnt. Press.

Mlde Range PI-63068 Ctnt. Press.

Mide Range Ind.

PR-6306B Ctnt. Press.

Mlde Range Note 8 Note 8 Note 1

Note 8 Note 8

PI-6306B PR 6306B PT 6306A PI-6306A PR-6306A Yes Yes Yes Yes Yes Ycs B15 NAINIAININCCI)tr. INIKCRITY CI)II. ISO)ATION VALVE POSITI NOV-744A RHR to Cold Leg, I.C.

HS 744A Mtth Ind. Lights

)NV-7448 RHR to Cold Leg I.C.

HS-744b

'Mlth Ind. Ltghts Open Closed Closed Not Closed Coup 1y Note 5

Note 8 Note 5

Note 8

Note 9 N/A N/A N/A N/A Note I SAS Yes Yes Yes Yes Ycs Note 24 Yes Note 24 oto aao00 a s sa

PARAMETER SUHHARY SHEETS IINIT Tmum POINT Sheet ITEM TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MEN I'NVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN POWER DANCE SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULE/

JUSTIFICATION HOV-716A HS-716A INV-716B HS-716B HOV-626 HS-626 HOV-730 HS-730 CV-739 (LS)

HS-739 HOV-1417 HS-1417 HOV-1418 HS-1418 CV-200h (LS)

HS-2004 CV 200B (LS)

HS-200B CV-200C (LS)

HS 200C RCP Thereal Barrfsr CCQ

'Qith Ind. Lights RCP Thereal Barrfer CCQ Qith Ind. Lights RCP h, B, C Thereal Barrier Coolfng Qtr. "

Qfth Ind. Lights CCQ froe RCP A, B, C

Cooler Bearing Qlth Ind. Lights Excess Letdovn Hect Exchanger Qtth Ind. Lights CCQ to Noreal CPtr. Coolfng Qith Ind. Lights CCQ free Noreal Ctet. Cooli Qith Ind. Lights Letdovn I.fne Qith Ind. Lights Letdovn Line Qfth Ind. Lights Lctdovn Lfne Qith Ind. Lights Open Closed Closed Not Closed Coeply Hill Coeply Coeply Hill Coop ly l~ly Qi 1 1 Coop ly Coep ly Note 8 Note 5 Note 8 Note 5

Note 8 Note 2 Note 8 Note 2 Note 8 Note 2 Note 8 Note 9 Note 11 Note 9 Note 11 Note 9 Note 11 Note 9 NIA Note 13 SAS Ycs Yes SAS Yes Yes SAS Yes Yes SAS Yes Ycs Note 14 SAS Yes Note 14 Yes Note 13 SAS Ycs Yes SAS Yes Yes Note 14 SAS Yes Yes SAS Yes SAS Yes Yes Yes Yes Yes Ycs Ycs Yes Yes Yes Yes Note 24 Note 24 Note 24 Note 24 Note 24 Note 24 Note 24 Note 21 Note 21 Note 21 Gto ~ Nooo ~ x s ss

r PARAHETER L SUmRY SHEETS UNIT 4 TURKEY POINT Sheet ot ITEM TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE'NVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION TSC EOF CR SCHEDULEI JUSTIFICATION CV 204 (LS)

BS 204 HOV-381 BS-381 CV-4658A (LS)

BS-4658A CV 46588 (LS)

BS 46588 CV-4668A (LS)

BS-4668A CV 46688 (LS)

BS 4668B CV&659A (LS)

HS-4659A CV-46598 (LS)

BS 4659B IIOV-866A HS 866A HOV-866B BS 8668 Letdovn Line Lou Press.

With Ind. Lights RCP Seal Wtr. Return Vlv.

With Ind. Lights RCUt Vent Vlv.

With Ind. Lights RCUI'ent Vlv.

'Mfth Ind. Lfghts RCUt Dtsch. to Hold-Up Tank With Ind. Lights RCUt Dtsch. to Hold-Up Tank With Ind. Lights RCUt Lfne to B2 Anal.

With Ind. Lights RCPt Line to H2 Anal.

With Ind. Lfghts Hi Head Safety In). Line With Ind. Lights Ht Bead Safety Inj. Lfne Mtth Ind. Lights Open Closed Closed Noc Closed Comply Comply Comply Coop ly Will Coop ly Cosply Will Comply Coep ly

'Mill Comply Corp ly Mill Comply Coop ly Will Comply Corp ly Will Comply Comply Mill Coop 1y Coep ly Will Coop ly Corp ly Note 8 Note 8 Note 8 Note 8 Note 2 Note 8 Note 2 Note 8 Note 2 Note 8 Note 2 Note 8 Note 2

Note 8 Note 2 Note 8 Note 2 Note 8 Note 2 Noes 8 Note 9 Note 9 Note 9 Note 9 Note 11 Note 10 Note ll Note 10

'ote ll Note 10

'ote 11 Note 10 Note il Note 10 Note 11 Note 10 Note 11 Note 9 Note 11 Note 9 NIA Note 1

Note I Note I Note I Note 14 Note 13 Ycs Yes Yes Ycs SAS Yes Yes Yes Yes Yes SAS Yes Yes Yes Note 24 Yes Yes Note 24 Yes Yes Note 22 Yes Yes Note Ycs Ycs Note 22 Ycs Yes Note 22 Yes Ycs Note 22 Ycs Yes Note 22 Ycs Ycs Note 21 Yes Yes Note 21

@to smoo x 9/89

PARAHETER L i

SWARY SHEETS UNIT 4 TURKEY POINT Sheet oI 46 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY CATE INSTRUMENTRANGE EXISTING REQUIRED ENVIRONMENTAL SEISMIC MENT QUALIFICATION QUALIFICATION REOUN.

DANCE POWER SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULEI JUSTIFICATION HOV-869 Hf Head Safety In). Lfne Open Closed Closed Not Closed Coop ly Note 5

Note 9 NIA Note u SAS Yes Yes HS-869 HOV 880A Mfth Ind. Lfghts Ctac.

Spray Punp A Dfsch.

Vlv.

Note 8 Note 5 Yes SAS Ycs Ycs HS-880A Mfth lnd. Lfghts IIOV 880B Ctnt. Spray Punp B Dfsch.

Vlv.

HS-880B Mfth Ind. Lfghts CV 956A OS)

PRER Scn.

Space Sanple HS 956A Mfth Ind. Lfghts CV 956B (LS)

PRZR Lfqufd Space S~le HS-956B

'Mfth Ind. Lfghts SV-6427A Hot Lcg RCS Sanple HS-6427A Mfth Ind. Lfghts SV-64278 Hot Leg RCS Sasple HS-6427B

'Mfth Ind. Lfghts SV-6428 Hoc Leg RCS Saaple HS-6428 Mich lnd. Lfghts SV-2912 Ctnt. Afr Sanple HS-2912 Mfch lnd. Lfghts SV-2911 Ctnt. Afr Ssnple HS-2911

'Mfth Ind. Lfghts SV-2913 Ctnt. Afr Sanple HS-2913 Mfth Ind. Lights Note 8 Note 5

Note 8 Note 8 Note 8 Note 8 Note 8 Note 1

Note 8 Note 1

Note 8 Note 1

Note 8 Note I Note 8

Note 1

Note 8 Note 1

Note 8 e 10 Not Note 9 Note 10 Note 9 Note 10 Note 9 Note 14 Note 12 Yes SAS Yes Yes Yes SAS Ycs Yes Ycs SAS Yes Yes Yes SAS Ycs Ycs Yes SAS Yes Ycs SAS Yes Yes SAS Ycs Yes Ycs SAS Yes Yes Yes SAS Yes Ycs Ycs ciao LxKo.x sts)

PARAHEIER SIR0IARY SHEETS UN Y POINT et 14 OI 46 TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL QUAUFICATION SEISMIC QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULEI 4USTIFICATION CV-519h (LS)

HS 519A POV-2600 (LS)

HS-2600 POV-2601 (LS)

HS-2601 POV-2602 (LS)

HS-2602 POV-2603 (LS)

HS-2603 POV 2604 (LS)

HS 2604 HOV 1400 HS-1400 HOV 1403 BS 1403 POV-2605 (LS)

BS-2605 HOV-1404 BS-1404 HOV-1401 BS 1401 PRER Relief Tnk. Dcmta. Mtr.

B Mtth Ind. Lights Cent.

Purge

'Mtch Iad. Lights Ctet. Purge Mith Iad. Lights Ctmt. Purge

'With Ind. Lights Ctmt. Purge Mith Ind. Lights Hain Scm. HSIV S.C.

'A'ich Ind. Lights Hctn Ste. Ltae ehe Mfch Ind. Lights Hain Ste. Ltne

'A'tth lnd. Lights Heim Stm. HSIV S,C.

'8'ith Ind. Lights Hcfn Scm. Line

'8'tth Ind. Lights Heim Sce.

Lfne

'8'Mich Ind. Lights Open Closed Closed Noc Closed Coop ly Comply Comply Coeply Mill Comply Coeply Coep ly Coeply

'Mill Coeply Coeply Mi1I Corply Coeply Coolly Comply Coop ly Coaply

'MtII Comply Comply Note 8 Note 8 Note 8 Note 8 Note 2 Note 8 Note 8 Note 8 Note 2 Note 8 Note 2 Note 8 Note 8 Note 8 Note 1

Note 8 Note 2 Note 8 Hole 5

Note 8 Note 8 Note 8 Note 9 Note 9 Note 9 Note 9 Note 11 Note 9 Note 9 Mote 9 Note 11 Note 9 Note 11 Rote 9

Note 9 Note 9 Note 10 Note 9 Note 11 Note 9 N/A Note 14 Note 13 Note 14 Note 14 Note 13 SAS Yes Yes Yes SAS Yes Yes Yes SAS Yes Yes Yes SAS Yes Yes Yes SAS Yes Yes Ycs SAS Yes Yes Ycs SAS Yes Yes Yes SAS Yes Yes Yes SAS Yes Yes Ycs SAS Yes Yes Ycs SAS Ycs Yes Yes Note 21 Note 21 Note 21 Note 21 ceo xxoo.x s ss

PARAMETER SmARY SHEETS UM RKEY POINI S fcgi IS Of 46 ITEM TAG NO VARIABLE DESCRIPTION GORY ATE.

EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

DANCE POWER SUPPLY TSC EOF DISPLAY LOCATION SCHEDULEI JUSTIFICATION POV-2606 (LS)

HS-2606 HOV 1405 HS-1405 HOV 1402 HS-1402 FCV-478 FCV-479 FCV-488 Hain Stm. HSIV S.C.

'C'fth Ind. Lights Hain Stm. Lfne eCa liith Ind. Lights Hain Stm. Line

'C'ith Ind. Lfghts S.C. 'A'eedvater Np Iadfcatioa S.C. 'A'eedvatcr No Iadfcatton S.C. '8'eedvater Mo Indtcatioa Open Closed Closed Not Closed Nfll Comply Comply Comply Comply Corp ly Comply Nfll Comply Note 2 Mote 8 Note I Note 8 Note 8 Note 8 Note 2 Note 11 Note 9 Note 10 Note 9 Note 9 Note 9 Note ll N/A Note 14 SAS Yes Yes Ycs Ycs Yes Yes Yes Yes Ycs Ycs Rotc 21 Ycs Yes Yes Note 22 Yes Yes FCV-489 FCV 498 FCV-499 CV-2816 (LS)

HIC-1401A CV-2831 (LS)

HIC-14018 CV 2817 (LS)

HIC-1457A S.C

'8'eedvater No Indication S.C. 'C'eedvater No Indication S.C. 'O'ecdvater No Indicatioa hux. Pcedvater to S.C.

'h'and Indicating Controller Aux. Feedvater to S.C.

h' Hand Indicatfng Controller Aux. Feedvater to S.C.

'8'ead Indicating Controller ly Note I Note 10 SAS Note 14 SAS Note 12 Yes Note 14 SAS Note 12 Yes Note 14 SAS Note 12 Yes Yes Yes Yes Ycs Yes Ycs Yes Yes Yes Ycs Ycs Ycs

@to sxxo x s ss

PARAMETER UNIT SIÃMARY SHEETS POINI'heet of TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALtFICATION REDUN.

DANCE POWER SUPPLY TSC EOF DISPLAY LOCATION SCHEOULEI JUSTIFICATION CV-2832 (LS)

Aux. Feedvater co S.C. 'b'pen Closed Closed Hot Closed Comp ly Note I Note 10 N/A Note 14 SAS Yes CV 2818 (LS)

Aua. Feedvater to S.C.

C'IC-1458A Hand Indfcating Controller CV 2833 (LS) hux. Feedvater to S.C.

'C'IC-14588 Hand Indicating Coatrol ler CV-6275A (LS)

S C.

ehe Blovdovn HS-6275A With Ind. Lights CV 6275B (LS)

HS 6275B CV-6275C (LS)

S.C.

eB ~ Blovdovn With Iad. Lfghts S.C. 'C'lovdova HS-6275C Wfth Ind. Lights HOV-1427 S C ehe Blovdovn Sacpl HS-1427 With Iad. Lights IIV-1426 S.C. '8'lovdova Sample HS-1426 With Iad. Lfghts

'RRI-1425 S C eC'lovdova Sample HS 1425 CV 2903 (LS)

HS-2903 CV 2904 (LS)

HS-2904 WfCh Ind. Lights CCW to Emergency Ctmt.

Cooler 8 With Ind. L1ghts CCW to Emergency Ctmt Cooler C With Ind. Lfghts HIC-14578 Head IndfcaCfag Coatrollcr W111 Coop ly Comply W111 Comply Ccmp ly Note I Note 8 Note 1

Note 8 Note 1

Note 8 Note 5 Note 8

- Note 5

Note 8 Note 5 Note 8 Note 2

Mote 8 Note 2 Noes 8

Note 9 Note 11 Hots 9 Note ll Note 9 Note 12 Ycs Note 14 Note 12 Ycs Note 14 SAS Note 12 Yes

.ote 14 SAS Yes Yes Yes

. ote 13 SAS Yes Ycs Yes Yes Yes Yes Ycs Yes Yes Ycs Ycs Yes Yes Yes Yes Yes Yes Yes Yes Note 22 Ycs Nocc 22

'PARANETER SUIDIARY SHEETS HNIT Y POINT 17 0 I 46 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY ATE.

INSTRUMENTRANGE EXISTING REQUIRED ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN-DANCE POWER SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULE/

JUSTIFICATION CV-2905 (LS)

HS-2905 CV-2810 (LS)

HS-2810 CV 2906 (LS)

HS 2906 CV-2812 (LS)

HS-2812 CV 2907 (LS)

HS 2907 CV 2814 (LS)

HS-2814 CV-2908 (LS) 8-2908

-872 HS-872 P-IW55 IS-855 CV-956D (LS)

S-956D CCM to Emecgency Ctat.

Cooler h Mtth Ind. Lfghts CCM froa Emergency Ctmt.

Cooler B Mtth Ind. Lfghts CCM frocc Emergency Ctat.

Cooler 8 Mfth Iad. Lfghts CCM from Emezgency Ctcct.

Cooler C

'Mfth Ind. Lfghts CCM from Emergency Ctmt.

Cooler C

'Mtth Iad. Lfghts CCM froa Emergency Ctmt.

Cooler A Mtth lnd. Lfghts CCM from Emergency Ctmt.

Cooler A Mtth Iad. Lfghts Lou Bead Safety Inject.

Mfth Ind. Lfghts N2 Supply to Accucculators Mtth Ind. Lfghts Accumulator Sacple Ltne Mtth Ind. Lfghts B

1 y

V Open Closed Closed Not Closed Mtl1 Coop ly Comply

'Mf11 Comply Comply Mfll Comply Comply Mf11 Comply Comply Mtll Comply Comply Mfll Comply Comply

. Mill Comply Comply Note 2 Note 8 Note 2

Note 8 Note 2 Note 8 Note 2 Note 8 Note 2 Note 8 Note 2 Note 8 Note 2 Note 8 Note 5 Note 8 Note 11 Note 9 Note 11 Note 9 Note 11 Note 9 Note 11 Note 9 Note 11 Note 9 Note ll Note 9 Note 11 Note 9 N/h Note 13 SAS Ycs Yes Yes Yes Ycs Yes Yes SAS Yes Note 14 SAS Note 14 Yes Note 14 SAS Hots 14 Yes Yes Yes Yes Ycs Yes Ycs Yes Ycs Yes Yes Note 22 Yes Note 22 Yes Note 22 Yes Note 22 Ycs Note 22 Yes Note 22 Yes Note 22 Ycs Yes ceo scooo x c sc

PARAMETER L UITKRY SHEETS UNIT POI NP S

eI 18 OI~4 ITEM TAG NO.

. VARIABLE DESCRIPTION TYPE CATE.

GORY INSTRUMENTRANGE EXISTING

'EQUIRED Q.A.

REQUIRE.

MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN POWER DANCE SUPPLY DISPLAY LOCATION EOF CR TSC SCHEDULEI JUSTIFICATION HOV-843A HS 843A

%V 8438 HS-8438 CV-2821 (LS)

HS-2821 CV 2822 (LS)

HS-2822 CV-2819 (LS)

CV-2826 (LS)

HOV 6386 HS 6386 CV-516 (LS)

HS 516 SV-6385 HS-6385 Boron Inj. Tank Out Stop Valve

'With Ind. Lights Boron In). Tk. Out Stop Vlv.

With Ind. Lights Ctnt.

Sunp Disch.

With Ind. Lights Ctaat.

Suaap Disch.

With Ind. Lights Inst. Air Bleed Inst. Air Blccd RCP Seal

'With Ind. Lights

~

Cas Analyzer Sanple Vlv.

With Ind. Lights Cas Analyzer Sanple Vlv.

With Indicating Lights Open Closed Closed Not Closed Coaaply Note 5

Note 8 Note 5 Note 8 Note 1

Note 8 Note 1

Note 8 Note 9 Note 10 Note 9 Note 10 Note 10 Note 9 Note 9 Note 9 Note 10 N/h Note 13 Yes SAS Yes Yes Note 14 SAS Yes Ycs SAS Yes Yes SAS Yes SAS Yes Note 13 SAS Yes Note 13 Yes Note 14 SAS Yes Ycs SAS Ycs Yes Yes Yes Yes Ycs Yes Yes Yes Ycs 816 PT-6306A PI 6306A PR 6306A NAINEAININCCONTAINMENP INTEGRITY CONTAINHENT PRESSURE Ctmt. Wide Range Press.

Ctnt. Wide Range Press. Ind.

Ctnt. 'Wide. Range Press.

0 - 180 PSIC

-5 PSIC to Design Pressure SEE ITEN B14 cao aaaoa

~ a s aa

ITEM TAG NO VARIABLE DESCRIPTION TYPE ATE.

GORY EXISTING REOUIRED PARAMETER UNIT INSTRUMENTRANGE SUIOULRY SHEETS TURKEY POINT RFPUI RE ENVIRONMENTAL SEISMIC MENT QUALIFICATION OUAUFICATION REDUN.

DANCE POWER SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULEI JUSTIFICATION HAINTAIHING coNIAIIOIENT INTECRITY CONTAINMENT PRESSURE (Continued)

PT-63068 Ctnt. Hide Range Press.

PI-6306B Ctnt. Qide Range Press.

Ind.

PR-6306B Ctnt. Ntde Range Press.

b 0

180 PSIC 5 PSIC to Design Pressure SEE ITEN B14 PT-6425h Ctnt. Narrov Range Press.

PI-6425B Ctnt.

PR-6306B Ctnt.

Narrov Range Press. Ind.

Narrov Range Press.

PI-6425A Ctnt. Narrov Range Press. Ind.

PR-6306A Ctnt. Narrov Range Press.

PT-64258 Ctnt. Narrov Range Press.

-6 to +18 PSIC

-5 PSIC to Design Pressure Coop ly Note I Note 8 Note 8 Note 1

Note 8 Note 8 Note 10 PT-64258 PI-6425B PR 63068 PT-6425A PI 6425A PR-6306A Note 12 SAS Ycs Ycs SAS Yes Yes Yes Yes cs cs oto saLLLO ~ a 9 99

ITEM TAG NO VARIABLE DESCRIPTION TYPE ATE.

GORY PARAMETER L UNIT INSTRUMENTRANGE EXISTING

'EQUIRED SmARY SHEETS Y POINf REQUIRE ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULE/

JUSTIFICATION Cl TE-IE Ihru IK 51E ICCS A ICCS 8 FUEL CIADDINC CORE EXIT TKNPERAT0 RE Core Exit Tenperature Dtsplay

'A'isplay'8'00 F - 2300 F 200 F 2300 P

Util Coop ly IIIII Coop ly Witt Coeply Note 2 Note 2 Note 2 Note 11 Note 11 Note 11 2 Channel Per Quadrant ICOS B

ICOS A Note 12 Note 12 Note 12 SAS Yes Yes Yes Yes Note 19 Note 19 Note 19 FUEL CIADDINC RADIOACTIVITY CONCENIRATION OR RADIATION LV IN CIRCUIATINC PRINARY COOIA Radtoactivtty Concentration or Radiation Level in Prhsary Coolant Crab Sanple II Tech. Spec.

Lhsit to 100 x Tech.

Spec. Lhsit No Inst. Exists In The Narket E 6312 FUEL CIADDINC ANALYSIS OF PRIIIARY COOIAÃI'x Cool. Utr. Radioactivity Analysis 10 p Ct/CC to 10 Ci/CC 10@. Ct/nl to 10 Ci/nl N/A N/A N/A N/A Note 15 SAS Yes Yes Pf-404 Rx COOIANf PRESSURE BOUNDARY RCS PRESSURE RCS Press.

0 3250 PSIG 0 - 3000 PSIC SEE ITEN Al PT-406 RCS Press.

ICCS A ICCS B Display

<Ac Display 'Bs cso. sxxo ~ x scat

PARAMETER LI SIItIARY SHEETS UNIT 4 TURKEY POINT ITEM TAG NO.

VARIABLE DESCRIPTION TYPE ATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE-MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN.

DANCE POWER SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULEI JUSTIFICATION C5 Pf-630&A PI-6306A PR 6306A Pf-63068 PI 63068 PR-63068 Rx COOIANI'RESSURE BOUNDARY CONfAINNKNT PRESSURE Ctmt. Wide Range Press.

Ctmt. Wide Range Prese.

Ind.

Ctat. Wide Range Press.

Ctmt. Wide Range Press.

Ctmt. Wide Range Press.

Ind.

Ctmt. Wide Range Press.

0 - 180 PSIG

-5 PSIG to Design Prcssure SEE ITEN 814 C6 Pf 6425A PI-6425A PR-6306A Pf-64258 PI 64258 PR 63068 Rx COOIANI'RESSURE BOUNDARY COÃfAINNKNfPRESSURE Ctmt. Narrov Range Press.

Ctmt. Narrov Range Press.

Ind.

Ctmt. Narrov Range Press.

C'tact Narrov Range Press, Ctmt. Narrov Range Press.Ind.

Ctmt. Narrov Range Press.

6 to +18 PSIG 5 PSIG to Design Pressure SKE ITEN 816 CI Rx COOIAÃf PRESSURE BOUICDARY CONTAIIOCKNf SUMP WATER IKVEL LT-6308A LI-6308h LR-6308A LT-63088 LI 63088 LR 63088 Ctnr..

Suscp Mater Level Ctnt.

Sump Water Level Ind.

Ctmt.

Sump Meter Level Ctmt.

Sump 'Mater Level Ctmt.

Sump 'Water Lcvcl Ind.

Ctmt.

Sump 'Mater Level

-18 Pt. Kiev. to Kl. 14'-0" 0 - 369" 0

369"

-18 Pt. Elev. to El 14'-0" 0 - 369" 0 - 369" Narrov Range (Sump)

SEE ITEN 812

~ )xxo x sac

PARAMETER LI UMMARY SHEETS UNIT 4 TURKEY POINT Shee 22 of ITEM TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE REQUIRE ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULE/

JUSTIFICATION CB LT-6309A LI 6309A LR-6309A LT-63098 LI-6309B LR 63098 Rx COOIANI PRESSURE BOUNDARY CONI'AINMKNT SUMP WATER LEVEL Ctnc. Water Level Ctnt. Mater Level Ind.

Ctnt. Water Level Cent. 'Mater Level Ctnt. Water Level Ind.

Ctnt. Water Level C

El. 14'-0" to El. 22'-0" 397 to 487" 397" Co 487" El. 14'" co El. 22'-0" 397" to 487" 397" co 487" Wide Range Plant Specific SKE ITEM B13 C9 D-63llh

-6311A

-6311B RR 6311B Rx COOIANI'RESSURE BOUmRY CONIAINMKNF AREA RADIATION Ctnt.HI Range Rad. Monitor

'h'tnt.HI Range Rad. Monitor

'A'tnt.HI Range Rad. Monitor

'B'tnt.HI Range Rad. Hoaltor'8'0

- 10 R/HR.

IRIHR.

10 RIHR.

N/A N/A N/A N/A Note 12 SAS Yes Yes SAS Yes Yes Yee Yes CI0 Rx COOIANI'RESSURE BOUNDARY KFFLUKÃI'ADIOACTIVITY-NOBLE CAS KFFLUKNI'ROM CONDENSER AIR REMOVAL SYSTEM EmUST D-6417 Alr E)actor Condenser Exhaust 10 co 10

+ CI/CC 10 co 10

~C I/CC N/A N/A N/A NIA Note 12 SAS Yes Yes cto.1xxo.x 9 9

PARAMETER LI SmelARY SHEETS UNIT 4 TURKEY POINT Sheet 23 Of ITEM TAG NO VARIABLE DESCRIPTION TYPE GORY CATE.

EXISTING, REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

POWER DANCE SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULE/

JUSTIFICATION C1 1 CONTAINNENP - RCS PRESSURE PT-404 RCS Press 0

3250 PSIG 0 - 3000 PSIG SEE ITEN hl PI-406 RCS Press.

ICCS A ICCS B Dtsplay

'h'tspley

'8'12 AI-6307A RR-6311A Ctat.

H2 Indtcator Ctat.

H2 Recorder E-63078 Ctat.

H Monttor I-63078 RR-6311B Ctat.

H2 Indtcator Ctat.

H2 Recorder CONCENTRATION AE-6307A Ctat.

H Nonttor C

0 102 0 - 10 Vol.E

~

Coaply Note 1

Note 8 Note 8 Note 1

Note 8 Note 8 Note 10 E-63078 Note 12 1-63078.

RR-63118 E 6307A I-63074 RR-631IA SAS Yes Yes Yes Yes SAS Yes Yes Yes C13 COÃIAINNENP CINP.

PRESSURE PT-6306A Ctat. Mtde Range Press.

PI-6306A Ctat. Mtde Range Press.

Ind.

I'R 63061 Ctat. Mtde Range Press.

PT 63068 Ctat. Mtde Range Press.

Pl-6306B Ctat. Mtdc Range Press.

Ind.

PR 6306B Ctat. Mtde Range Press.

C 1

0 180 PSIC

-5 PSIC to 3X Destgn Pressure SEE ITEN B14 aaxu.a siss

PARAMETER LI SUHNARY SHEETS UNIT 4 TURKEY POINT Sheet 24 OI ITEM TAG NO.

VARIABLE DESCRIPTION TYPE ATE GORY INSTRUMENTRANGE EXISTING

'EQUIRED ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN POWER DANCE SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULEI JUSTIFICATION PT-6425A PI-6425A PR-6425A PT-6425B PI-6425B PR-6425B CONTAINHENT CIHl'. PRESSURE (Continued)

Ctnt. Narrov Range Press.

Ctnt. Narrov Range Press.

Ind.

Ctnt. Narrov Range Press.

Ctat'. Narrov Range Press.

Ctnt. Narrov Range Press.

Ind.

Ctnt. Narrov Range Press.

-6 to +lg PSIC

-5 PSIC to 3X Design Pressure SEE ITEN B16 C14 RAD-6304 CONTAINMENT CIHF.EFFLUENF RADIOACTIVITY-NOBLECAS FROH IDENTIFIED RELEASE POINTS Vent Stack Mlde Range Honitor C

10 to 10

~Ci/CC 10 to 10'Cl/CC N/A Note 8 N/A N/A Note '12 Yss Yes RAD-6417 D-6426 Air E3ector Condenser Exh.

Stean Line Rad. Honitor SAS SAS Yes Yes Yes Yes CONTAINHENT EFFLUENT RADIO-ACTIVITYNOBLE CAS (Froa Bldg or'reas, etc.)

D-6304 Vent Stack 'Mide Range Honltor C

10 to 10 p,CI/CC 10 to 10

~CI/CC SEE ITEN C14 cpo 1&co.x s ss

ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY ATE.

PARAHETER SSARY SHEETS UNIT 4 TURKEY POINT INSTRUMENTRANGE EXISTING

, REQUIRED Q.A.

REQUIRE.

MENT ENVIRONMENTAL

- SEISMIC QUALIFICATION QUALIFICATION REDUN.

DANCE POWER SUPPLY CR TSC EOF SCHEDULE/

JUSTIFICATION Sheet 2$

Of 46 DISPLAY LOCATION Dl FT-60$

F 1-60$

RHR SYSTEM-RHR SYSTEH FLOM RHR System Flov RHR System Flov Indicator 0

8300 CPH 0

IIOE Dcslgn F lov Comply Comply Note 1

Note 8 Note 10 Note 9 N/A N/A'ote 12 SAS Yes Note 12 cs Yes D2 TE-606 RHR SYSTEM - RHR Hr DUPLET TEHPERAYURE RHR Hx Outlet Temperature

$0 - 400 F Comply Note 6 Note 9 N/A Note 12 SAS Yes Ycs TR-604 RHR Hx Outlet Temperature Recorder Comply Note 8 Note 10 N/A Note 12 es D3 LT 920 LI 920 LT 922 Ll-922 LT-924 LI-924 LT 926 LI-926 LT-928 LI-928 LT-930 LI-930 S.I.S. - ACCUHUIATOR TAN(

LEVEL Accumulator Tank Level

~h'ccumulator Tank Level

'A'nd.

hccmmslator Tank Level

'A'ccumulator Tank Level

'A'nd.

Accumulator Tank Level

'8'ccumulator Tank Level

'B'nd.

Accumulator Tank Level

'8'ccumulator Tank Level

'B'nd.

hccucmlator Tank Level

'C'ccusaalator Tank Level

'C'ccusulator Tank Level

'C'ccumulator Tank Level 'C' 2

6133-6761 Chl.

(Narrov Range) 6000-7000 CAL 6133-6761 CAL (Harrov Range) 6000 7000 CAL 6133-6761 CAL (Narrov Range) 6000-7000 CAL 6133-6761 CAI.

(Narrov Range) 6000-7000 CAL 6133-6761 CAL (Narrov Range) 6000-7000 CAL 6133-6761 CAL (Narrov Range) 6000-7000 CAL IOE to 902 Volume

'Hill Comply Comply Hill Comply Comply Nill Comply Comply HI11 Corp ly Comply HIII Comply Coup ly HI11 Comply Comply Note 2 Note 8 Note 2 Note 8 Note 2 Note 8 Note 2

Note 8 Note 2 Note 8 Note 2

Note 8 Nota ll Note 9 Note 11 Note 9 Note 11 Note 9 Note 11 Note 9 Note 11 Note 9 Note ll Note 9 LT-922 LI-922 LT-920 LI-920 LT-926 LI 926 LT-924 LI-924 I.T-930 LI-930 LT-928 LI-928 Note 12 SAS Yes Yes SAS Yes Yes SAS Yes Yes SAS Ycs Ycs SAS Ycs Ycs SAS Ycs Ycs Ycs Yes Yes Yes Yes Ycs Note 22 6 28 Note 22 6 28 Note 22 6 28 Note 22 6 28 Note 22 6 28 Note 22 6 28

PARAMETER

SUMMARY

SHEETS UNI RKEY POINT ITEM TAG NO VARIABI.E DESCRIPTION TYPE GORY'ATE.

EXISTING REQUIRED INSTRUMENTRANGE REQUIRE ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN-DANCE POWER SUPPLY DISPLAY LOCATION EOF TSC SCHEDULE/

JUSTIFICATION D4 PI-921 PT-923 PI-923 PT-925 PI 925 PT-927 PI-927 PT-929 PI 929 PT-931 PI-931 Accumulator Tank Pressure

'h'nd.

Accumulator Tank Pressure

'h'ccumulator Tank Pressure

'h'ad.

Accumulator Teak Pressure

'B'ccumulator Tank Pressure

'B'ad.

Accumulator Teat Pressure

'B'ccumulator Task Prcssure

'b'nd.

Accurulator Tant Pressure

'C'ccusulator Task Prcssure

'C'nd.

Accumulator Tank Pressure

'C'ccusmlator Tank Pressure

'C'nd.

S.I.S.

ACCUMUIATOR TAHE PRESSURE PT 921 Accusmlator Tank Pressure

'A'

- 800 PSIC 0 - 750 PSIC Comply Note I Note 8 Note 1

Note 8 Note I Note 8 Note 1

Note 8 Note I Note 8 Note 1

Note 8 Note 10 Note 9 Note 10 Note 9 Note 10 Note 9 Note 10 Note 9 Note 10 Note 9 Note 10 Note 9 PT-923 PI-923 PT-921 PI-921 PT-927 PI-927 PT 925 PI-925 PT-931 PI-931 PT-929 PI-929 Note 12 SAS Tcs Yes Yes Yes Ycs Yes Yes Yes Yes Ycs Ycs Yes Yes Yes Ycs Yes Yes D5 HOV 865A HS-865A S.I.S.

ACCUMULATOR ISOIATIO VALVE POSITION Accumulator Tank Isolation Valve

'A'ccusaslator Tank Isolation Valve eh>

Closed or Open Closed or Open Comply See Schedule/

Justiifcatioa See Schedule/

Justfffcation N/A Note 13 SAS Ycs Ycs Ycs These Valves Are Locked Open 8658 Accumulator Tant Isolation Valve'8'es Ycs US-8658 Accumulator Tank Isolatioa Valve ebs Yes OV 865C S-8650 Accumulator Tank Isolation Valve

'C'ccusmlator Tank Isolation Valve'C'cs Yes Gto ~ sxo) ~ a 9 a)

PARAMETER SUItIARY SHEETS UNIT aKEY POINT

~7 OI 44 ITEM TAG NO.-

VARIA8LE DESCRIPTION TYPE GORY ATE.

INSTRUMENTRANGE EXISTING REQUIRED REQ I

ENVIRONMENTAL SEISMIC MENT QUALIFICATION QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION CR TSC EOF SCKEDULE/

JUSTIFICATION D6 FT-943 FI 943 S.I.S. - BORIC ACID CHARGINC FMM Boric Acid CharBin8 Flov Baric held CharBlng Plav Ind.

0 1000 CPM 0

IIOX Des IBn Flow Conply Caeply Note 1

Note 8 Note 10 Nate 9

N/A N/A Note 12 Note 12 SAS Yes Yes Yes Dy FT 940 FI-940 S.I.S FLOW IN HPI SYSTEM HPI Systen Flow HPI Systen Plow lnd.

i t

0 1000 CPM 0

1101 Des IBn Plow Cooply Coeply Note I Note 8 Note 10 Note 9 N/A ote 12 Note 12 SAS Yes Yes Yes DB PT-605 FI-605 S.'I.S. - FUSI IN LPI SYSTEM LPI Systen Flov LPI Systea Flov Ind.

0.

1000 CPM 0 - IIOE Design Flov Coop ly Coop ly Note L Note 8 Note 10 Note 9 N/h N/A Note 12 Note 12 SAS Yes Yes LT 6583h LI-6583h LT 6583B LI-6583B S.I.S.

REFUELIIS NhTER STORAGE TANK RUST Level RHST Level Indtcator RMST Level RUST Level Indicator 0 - 330,000 Cal.

Top to Botton SEE ITEM A4 cpo

~ )xao a s's)

PARAMETER Li

SUMMARY

SHEETS UNIT 4 TURKEY POINT ITEM TAG NO.

VARIABLE DESCRIPTION TYPE ATE.

GORY EXISTING REQUIRED.

INSTRUMENTRANGE REQUIRE QUALIFICATION SEISMIC QUALIFICATION REDUN.

DANCE POWER SUPPLY TSC EOF DISPLAY LOCATION SCHEDULE/

JUSTIFICATION DIO 3P200A 3P200B 3P200C PRIHART COOIAHT SYSTEH RCP MOTOR STATUS RCP 'A'tr. Current RCP 'A'tr. Current Indicato RCP 'B'tr. Current RCP 'B'tr. Current Indieato RCP 'C'tr. Current RCP 'C Mtr. Current Indieato 0

1200 AHP Htr. Current N/A N/A N/A N/A Note 16 No Note 14 Yes Mote 16 No Note 14 Ycs Note 16 No Note 14 Yes No No No Dl1 PCV 455C PCV-456 2S 63034 2S-6303B 25-63030 PRIMARY COOIAÃP SYSTEM PRIHART SYSTEM SAFETY RELIEP VAI.VE POSITION PRZR PORV PRZR PORV Positioa Indication Lights for PCV 455C d 456 Primary System Safety R.V.

Code Safety Valve Primary System Safety R.'V.

Code Safety Valve Primary System Safety R.V.

Code Safety Valve Open Closed Closed Not Closed Closed Not Closed Hill Coeply Hill Comply Corp ly Note 2 Nose 2

Mote 1

Note 11 Note 11 Note 10 N/A N/A N/A Note 14 SAS Note 14 SAS Ycs Note 12 SAS Yes Ycs Yes Yes Ycs Note 21 Yes Note 21 Ycs Yes Yes Readout ia CR for tS 6306A, B, C Ycs cto ~ 1&00 ~ a as'

PARAMETER L UNIT 4 IBBIARY SHEETS POINT ITEM TAG NO.

012 VARIABLE DESCRIPTION PRIMARY COOLANT SYSTEM PRESSURIZER iEVKL TYPE CATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE REQUIRE ENVIRONMENTAL MENT QUALIFICATION SEISMIC QUALIFICATION REDUN POWER DANCE SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULE/

JUSTIFICATION LR-459 PRZR Level Recorder for LT-459, 460, 461 LT-4S9 PRZR Level Ch. I LI-4S9 PRZR Level Ch. I Ind.

LT-460 PRZR Level Ch. II LI-460 PRZR Level Ch. II Ind.

LT 461 PRZR Level Ch. III LI-461 PRZR Level Ch. III Ind.

0 181" 0

IOOZ 0

181" 0 - 100'I 0 - 181" 0 - IOOZ 0

IOOZ Top to Bottom Comply Note 1

Note 8 Note 1

Note 8 Note 1

Note 8 Note 8 Note 10 Note 9

Note 10 Note 9 Note 10 Note 9 Note 9 LT-460 LT-461 LI-460 LI 461 LT-459 LT-461 LI-459 LI-461 LT-459 LT-460 LI-459 LI 460 N/A Note 12 Yes SAS SAS SAS Ycs SAS SAS SAS Yes Ycs 3811 3B12 PRIMARY COOIAÃP SYSTEM PRESSURIZER HEATER STATUS PRZR Hcatcr Status PRZR Heater Status Indicating Light PRZR HcaCcr StaCus PRZR Heater Status Indicating LighC On-Off Light On-Off Light Current Ui1 1 Comply Comply Nil1 Comply Corp ly Note 2

Note 8 Note 2 Note 8 Note ll NoCc 9 Note 11 Note 9 N/A Note 17 Note 14 Note 17 Note 14 SAS Ycs Yes Yes SAS Yes Yes Yes Note 22 Note 22 3813 PRZR Heater Status PRZR Heater Status Indicating Light 0 - 600 A Ni1 1 Comply Comply Note 2 Not'e 8 Note 11 Note 9 Note 17 Note 14 SAS Ycs Yes Yes Note 22 pRIMARY cooihttr sYsTEM LT-470 PRZR Relief Tank Level (Quench Tank) 0 - 1007.

Top to Bottom N/A N/A N/A N/h Note 12 SAS Yes Yes LI-470 PRZR Relief Tank Level Indicator (Quench Tank)

N/A N/A N/A N/A Note 12 Yes cpo sxoo

~ x v s?

PARAMEIER L

SUMMARY

SHEETS UNIT 4 TURKEY POINT S eet Io of 46 ITEM TAG NO.

VAR!ABLE DESCRIPTION

~PE GORY'TE.

INSTRUMENTRANGE EXISTING REQUIRED REQUIRE-ENVIRONMENTAL SEISMIC MENT QUALIFICATION QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULE/

JUSTIFICATION D15

'E-471 T1-471 PRIMARY COOIANI'YSTEM UENCH TANK TEMPERATURE PRZR Relief Tank Tenperature PRZR Relief Tank Tcnperature Indicator 50 - 350 F 50 750 F N/A N/A-N/A N/A N/A N/A N/A Rote 12 Note 12 SAS Ycs Ycs Yes D16 PT-472 PI-472 PRIMARY COOIAÃI'YSTEM UENCH TANK PRESSURE PRZR Relief Tank Pressure PRZR Relief Tank Pressure Indicator N/A N/A N/A

. N/A N/A N/A N/A N/A Note 12 Note 12 SAS Yes Yes Yes D17 LT-474 LI-474 LT 475 LI&75 LT~76 LI-476 IR&78 SECONDARY SYSTEM (Stean Ccn.)

S.C.

ILVEL S.C, 'A'evel Ch. I Narrow Range S.C. 'A'evel Ch. I Narrow Range Ind.

S C IA~ Level Ch. II Narrow Range S.C. 'A'evel Ch. 11 Narrow Range Ind.

S.C. 'A'evel Ch. III Narrow Range S.G. 'A'evel Ch. III Narrow Range lnd.

S.C. 'A'evel Ch. I. II, III Recorders

- Narrow Range 30.1" to 138.22" Frees Tube Sheet to Separators 0 - 1002 30.1" to 138.22" 0 - 1002 30.1" to 136.22" 0 - 1002 0 - 1002 SEE ITEM A5 Note 23 cd ~ Ooooo a 9 99

ITEM TAG NO.

VARIABLE DESCRIPTION TYPE ATE.

GORY EXISTING REQUIRED PARANETER UNIT INSTRUMENTRANGE

SUMMARY

SNEETS Y POINT REQUIRE ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION CR TSC EOF 31

( I 46 SCHEDULEI JUSTIFICATION LT-484 LI&84 LT-485 LI-48S LT-486 LI-486 LR-488 SECONDARY SYSTEM STEAM CENERA R

S.C.

LEVEL (Continued)

S.C. '8'evel Ch I Narrov Range S C~ <<B<<Level Ch. I Narrov Range Ind.

S.C. '8'evel Ch. II Natrov Range S.C. 'B'evel Ch. II Narrov Range Ind.

S.C. 'B'evel Ch. III Natro>>>> Range S.C. 'B'evel Ch. III Natrov Range Ind S.C. 'B'evel Ch. I, II, III Recorders I

30.1" to 138.22" 0 - 1002 30.1" to 138.22" 0 -

TOOL 30.1" to 138.22" 0 - IOOZ 0 - 1002 Pro>>a Tube Sheet to Separators SEE ITEM A5 hotc 23 LT<94 LI-494 LT-495 LI-495 LT-496 Ll-496 LR-498 S.C. 'C'evel Ch. I Narrov Range S.C.

>>C>> Level Ch. I Natrov Range Ind.

S.C. 'C'evel Ch. II Narrov Range S.C. 'C'evel Ch. II Narrov Range Ind.

S C

<<C>> Level Ch. III Narrov Range S.C. 'C'evel Ch. III Narrov Range Ind.

S.C. 'C'evel Ch. I ~ II, III Recorders 30 lu to 138.22" 0 - 1002 30.1" to 138.22" 0 - TOOL 30 1>>>> to 138 22a 0 - IOOZ 0

IOOI o<<o laxo>>>> 9a<<

0 PARAHETER LI FRIARY SHEETS UNIT 4 KEY Poly S

~2 Of 46 VARIABLE DESCRIPTION SECONOARY SYSTEII S.C.

TYPE GORY CATE.

INSTRUMENTRANGE EXISTING

'EOUIRED REQUIRE ENVIRONMENTAL SEISMIC MENT OUALIFICATION OUALIFICATION REDUN-POWER DANCE SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULEI JUSTIFICATION PT-474 PI-474 PT-475 PI-475 PT-476 PI-476 S.C.

PRESSURE S.C. 'A'tems Pressure Ch. II S.C. 'A'teas Pressure Ch. II Ind.

S.C. 'A'teas Prcssure Ch. III S.C. 'A'tcas Pressure Ch. III Ind.

S.C. 'A'teaa Pressure Ch. IV S.C. 'A'team Pressure Ch. IV Ind.

0 - 1400 PSIC fROM AINOS.PRESS 202 Above Lovest.S.V.

SettlnE Comply Note 2 Note 8 Note 2 Note 8 Note 2 Note 8 Note 10 PT-475 PT-476 PI-475 PI-476 PT-474 PT-476 PI-474'I-476 PT-474 Pf-475 PI-474 PI-475 Note 12 SAS Ycs Yes Ycs SAS Yes Yes Yes SAS Yes Yes Conax Seal Connectors ulll be provfdcd by the end of the next refuelfo8 outage PT-484 PI-484 PT-485 PI-484 Ff-486 PI-486 S.C. '8'teas Pressure Ch. II S.C. 'B'team Pressure Ch. II Ind S.C. 'B'teas Pressure Ch. III S.C. 'B'teas Pressure Ch. III Ind.

S.C. 'B'teas Prcssure Ch. IV S.C. '8'teasI Pressure Ch. IV. Ind.

Note 2 Note 8 Note 2 Note 8 Note 2 Note 8 PT-485 PT-486 PI-485 PI-486 PT-484 PT-486 PI-484 PI-486 PT-484 PT-485 PI-484 P 1-485 SAS Yes Yes Yes SAS Yes Ycs Yes SAS Ycs Yes Yes Pf-494 PI-494 PT-495 S.C. 'C'tean Pressure Ch. II S.C. 'C'teas Pressure Ch. II Ind.

S.C. 'C'team Pressure Ch. III Note 2 Note 8 Note 2 Pf-495 PT-496 PI-495 PI-496 PT-494 PT-496 SAS Ycs Yes Yes SAS Yes Yes

PARAMETER L mARY SHEETS UNIT 4 Y POINT Sh 33 OI 46 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

GORY EXISTING REOUIREO INSTRUMENTRANGE O.A.

REQUIRE-MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

OANCE POWER SUPPLY DISPLAY LOCATION TSC EOF SCHEOULEI JUSTIFICATION PI-495 PT-496 PI-496 SECONDARY SYSTEM S.C.

STEAM GENERATOR PRESSURE (Conttnued)

S.C. 'C'teas Pressure Ch. IIIInd.

S.C. 'C'team Pressure Ch. IV S.C. 'C'teas Pressure Ch. IV Ind.

0 1400 PSIC FROM ATMOS.PRESS TO 202 Above Louest S.V.

Settfng l

Comply Note 8 Note I Note 8 Note 10 PI-494 PI-496 PF-494 PT-495 PI-494 PI-495 Note 12 Yes Yes Yes Yes Conax Seal Cermet tora ufll be pro-vfded by the end of thc next re-fueling outage.

D19 RV-1400 RV 1405 RV 1410 RV 1401 RV-1406 SECONDARY SYSTEM S.C.

SAFETY/RELIEF VALVE POSITIONS OR HAIN STEAN FUN Hain Steam Safety Valve Position Mafn Steam Safety Valve Position Main Steas Safety Valve Posttfon Mafn Steas Safety Valve Position Hain Steam Safety Valve Posttfon None Closed Not Closed See Sdxdule/

Justification See Schedule/

Justtffcatfon See Schedule/

Justification The Hain Steam Safety Valve Position Indica-tion ts Monitored by Hessurtng Hafn Stcam Ftou RV-1411 Matn Steam Safety Valve Position RV-1402 RV-1407 RV-1412 RV 1403 Hain Steam Safety Valve Posit ton Hafn Steaa Safety Valve Position Matn Steas Safety Valve Posttton Hain Steam Safety Valve Posftion cto sxxo x ass

PARAHETER L SIRIARY SHEETS UNIT 4 TURKEY POINf ITEM TAG NO.

VARIABLE DESCRIPTION GORY CATE.

INSTRUMENTRANGE EXISTING REQUIRED Q.A.

REQUIRE.

MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REOUN.

DANCE POWER SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULE/

JUSTIFICATIOfl RV-1408 RV-1413 SECONDARY SYSTEH S.C.

SAFETY/RELIEF VALVE POSITIONS OR HAIN STEAN FLNl (Conttnued)

Hain Stems Safety Valve Position Hain Steam Safety Valve Fosltlon Closed Not Closed See~

Justtficat ten Scc Schedule/

Justlflcatlon See Schedule/

Just if Ication The Hain Stean Safetv Valve Position Indi cation Is Honttored by HeasurlnR Hstn Stcam Flow D20 SECONDARY SYSTEH S.C HAIN FEEDMATER PMM FT-476 S.C. 'A'.'M. Plow Ch. III 0 - 4 x 10 LB/HR 0 - 1101 Desl8n Plov N/A N/A N/A N/A Note 12 SAS Yes Yes PI-476 PT-477 PI-477 FT-486 FI-486 IT 487 FI 487 FT-496 FI-496 FT-497 FI 497 S.C.

'A'nd.

S.C.

'A'.C.

'A'nd.

S.C.

'B'.C.'8 I Ind.

S.C.

'B'.C.

IB'nd.

s.c.

'c'.c.

'c'nd.

S.C.

'C'.M.

Flow Ch. III P.M. Plow Ch. IV F.M. Flov Ch. IV F.M. Plov Ch. III F.M. Flow Ch. III F.'M. Flov Ch. IV F.M. Flow Ch. IV F.M. Flov Ch. III F.M. Flov Ch. III F.M. Flow Ch. IV S.C. 'C'.M. Flow Ch. IV Ind.

Yes SAS Yes Yes SAS Ycs Yes SAS Yes Yes SAS Ycs Ycs SAS Ycs Yes Yes Yes Yes CPO. i&00~ a le)

PARANETER I.

SUNNARY SWEETS UNIT 4 TURKEY POINT Stleet~ of~4 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY'ATE.

EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN.

POWER DANCE SUPPLY DISPLAY LOCATION EOF CR TSC SCHEDULEI JUSTIFICATION D21 AUXILIARYFEEDVATER AUXILIARYFEE OVATER FLOW FT 1401A hux. P.W. Flov to S,C.

'A 0 - 300 CPN 0

11 OX Destgn Plov Couply Note 1

Note 10 FT-1401B Note 12 SAS Yes FI-1401A FT 1401B PI-14018 PT 1457h FI 1457A IT 14578 PI-14578 FT-145&A PI 1458A FT-14588 Aux, P.W. Flov to S.C.

'A'nd.

hux. F.W. Plov to S.C.

'A'ux.

F.W. Flov to S.C.

'A'nd.

Aux. P.W. Flov to S.C s&s Aux. F.W. Flov to S.C eB ~

Ind.

Aux. P.W. Flov to S.C eBs Aux. F.W. Flov to S.C.

'B'nd.

Aux. F.W. Plov to S.C sCe hux. P.'W. Plov to S.C.

'C'nd.

Aux. P.W. Flov to S.C.

'C'l 145&8 Aux. P.W. Plov to S.C.

'C'nd.

Note 8 Note I Note 8 Note I Note 8 Note 1

Note 8 Note 1

Note 8 Note I Note 8 FI-1401B FT-1401A FI-1401A PT-14578 FI-14578 FT-1457A FI-1457A FT-14588 FI-145&B FT-145&A FI-145&A Ycs SAS Yes Yes SAS Yes Yes SAS Yes Ycs SAS Ycs Ycs SAS Yes Yes Yes Yes Yes Ycs Yes AUXILIARYFEEINATER CONDENSATE STORACE TANK WATER LEVEL LT-6384A LI-6384A LT-63848 Condensatc Storage Tank Condensate Storage Tank Ind.

Condensate Storage Tank LI-6384B Condensate Storage Tank Ind.

D 1

0 - 1002 Plant Spccfftc Coup ly Note I Note 8 Note 1

Note 8 Note 10 LI-63848 LT-6384A LI-6384A Yes SAS Yes Yes LT-63848 Note 12 SAS Yes Yes Ycs

'ARAMETER L

SUMMARY

SNEETS UNIT 4 TURKEYPOINI'nuof 36 of 46 ITEM TAG NO.

VARIABLE DESCRIPTION GORY CATE.

EXISTING REQUIRED INSTRUMENTRANGE REQUIRE ENVIRONMENTAL O.A.

QUALIFICATION SEISMIC QUALIFICATION REDUN POWER DANCE SUPPLY CR TSC EOF DISPLAY LOCATION SCHEDULE/

JUSTIFICATION D23 None CONTAIIOIENf COOLINC SYSTEM CONTAINMENT SPRAY FLOCC Containncnt Spray Fiocc D

2 0 - Iform Desfgn Flov See Schccfcic/

JustiBcsti See Schedule/

Justlficatfon See Schedule/

Justification The Operation of the Ctcct. Spray Systen is Monitor ed by the Ctnt.

Spray Actuation Signal, the Indi-cation of Pucp Starting and Vabce os it Ion Ind Ic~

n the Control Rcc D24 CONfAIIOCENf COOLINC SYSTEM NFAT REMOVAL DY 'Blg CTMI'AN NEAT REMOVAL SYSTPA TE-1481 Ctnt. Cooler hfr Tcop. Outlet D

TE-1483 Ctnt. Cooler hir Tcccp. Inlet TE-1482 Ctnt. Cooler *frTeep. Outlet TE-1484 Ctnt. Cooler hfr Teccp. Inlet TE-1485 Ctnt. Cooler hfr Tenp. Outlet TE-1487 Ctnt. Cooler hir Tccp. Inlet TE-1486 Ctcct. Cooler hir Tenp. Outlet TE-1488 Ctnt. Cooler hfr Teep. Inlet R 1413 Ctnt. Tescp.

Recorder 0 - 300 F Plant Speciffc N/A Note 3 Note 8 Note 9 N/h Note 15 No Tcs Yes 025 COÃfhINMEÃf COOLINC SYSTEM CIMf. ATMOS. TEMPERATURE TE 1497 Ctnt. Atccos. Tenperaturc TE-1498 Ctnt. Atnos. Tcccperature TE-1499 Ctnt. Atnos. Tcccpcrature R-1413 Ctcct. Tcccperature Recorder 0-300F 40 400 F N/A Note 3 Note 8 Note 9 TE-1498 TE-1499 TE-1497 TE-1499 TE-1497 TE 1498 N/A Note 15 Yes Yes Yes Turkey Point Nax. Ctnt. Teep.

275 F.

ccco ccc00 ~ a c sl

PARAMETER Ll iN

SUMMARY

SHEETS UNIT 4 TURKEY POINT Sh ~I OI~

ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY ATE-INSTRUMENTRANGE EXISTING

'EQUIRED REQUIRE ENVIRONMENTAL SEISMIC MENT QUALIFICATI N QUALIFICATION REDUN POWER DANCE SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULE/

JUSTIFICATION 026 None COHI'AINMENP COOLINC SYSTEM COHTAIHMEHT SUMP HIR. TEMP.

Ctmt.

Sump Htr. Temperature D

2 50 - 250 P

Scc Schedule/

Jus tificsticn See Schedule/

Justification See Schedule/

Justificacion A Measuremcnt of the Ctmt. SumpLtr.

Tauon is Accom-plighcd vith the R.C. Hot Leg Temp

)he Hat~~ ]n the alvays Belov the Hat Lcg Tespcrsnne 022 FT-122 CHEMICAL & VOLUME COÃIROL SYSiEM MAKEUP FLOV Charging Plov 0

1102 Design Flov Comply Note 1

Note 10 N/h Note 12 SAS Yes Yes F1-122 Charging Flov Ind.

Comply Note 8 Note 9 N/A Note 12 Ycs D28 FT-150 CHEMICAL 4 VOLUME CONTROL SYSTEM - LETOOVN FIAN Lo Pressure Letdovn Flov 0

150 CPH 0

IIOE Design Flou Comply Note I Note 10 N/A Note 12 SAS Yes Yes FI-150 Lo Prcssure Letdavn Plov Ind.

Comply Note 8 Note 9 N/A Note 12 029 LT-115 LI-115 LT-112 LI-112 CHEMICAL 6 VOLUME CONIROL SYSTEM - VOLUME CONTROL TANK LEVEL Vol. Control Tank Level Vol. Control Tank Level Ind.

Vol. Control Tank Level Vol. Control Tank Level Ind.

0 1002 Top to Bottcxa Comply Note 3 Note 8 Note 3 Nate 8 Note 9 N/A Note 12 SAS Yes Ycs SAS Yes Yes Yes cca Nooo x s a>

ITEM TAG NO.

VARIABLE DESCRIPTION GORY CATE.

INSTRUMENTRANGE EXISTING REOUIRED REOUIRE.

ENVIRONMENTAL OUALIFICATION PARAHEIER L Stt&ARY SHEETS UNIT 4 TURKEY POINT SEISMIC QUALIFICATION REDUN.

DANCE POWER SUPPLY S

MHI~ Of~4 SCHEDULEI JUSTIFICATION DISPLAY LOCATION TSC EOF D30 TE 607A TI 607A TE-607$

Tl-60re COOLINO MATER SYSTKH COHPONEÃr COOLINC MATER TEHP.

TO ESP SYSTKH Coeponent Cooling Hx Outlet Tcnpcraturc Coeponent Cooling Hx Outlet Tenpcrature Ind.

Cosponcnt Cooling Hx Outlet Tcnperaturc Coeponent Coolfng Hx Outlet Tcnperature Ind.

50 200 F 40 200 F Coup ly Note 3 Note 8 Note 3 Note 8 Note 9 N/A Note 12 Yes Yes Yes Yes Ycs Yes D31 COOLINO MATER SYSTKH COHPOVKMI'OOLING MATER FLOM TO KSF SYSTEH FT-613A CCM Header Plov Fl-613h CCM Header Flou Ind.

FT-6138 CCM Header Flow FI-613B CCM Header Flou Ind.

0 - 14000 CPH 0

1102 Destgn Flou Cockily Note I Note 8 Note 1

Note 8 Note 10 Note 9 Note 10 Note 9 N/A Note 12 Yes Yes Ycs Yes Yes Yes D32 RADMASTE SYSTEHS MICH LEVEL RADICACIIVITY D. TANK LEVEL LT 1001 Mastc Holdup Tank Level LI 100th Mastc Holdup Tank Level Ind.

Top to Button N/A N/h N/A N/A N/A N/h N/A N/A Note 15 Note 15 Yes Ycs Yes Pneunatic ceo

~ sxxn.x s.sj

PhRANETER L SUNNARY SHEETS UNIT 4 TURKEYPOINI'heet ~ of 46 TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN.

POWER DANCE SUPPLY DISPLAY LOCATION CR TSC EOF SCNEDULEI JUSTIFICATION PT-1036 PI-1036 PT 1037 PI 1037 PT 1038 PI-1038 PT-1039 PI 1039 PT-1052 PI 1052 PT-1053 PI-1053 RhtsthSTE SYSTENS - RADIOACTIV CAS HOLDUP TANK PRESSURE Cas Decay Tank

'A'Holdup)

Pressure Cas Decay Tank

'A'loldup)

Pressure Iad.

Cas Decay Tank

'B'Holdup)

Prcssure Cas Decay Tank

'B'Holdup)

Pressure Ind.

Cas Decay Tank

'C'Holdup)

Pressure Cas Decay Tank

'C'Holdup)

Pressure Ind.

Cas Decay Tank

'D'Holdup)

Pressure Cas Decay Tank

'D'Holdup)

Prcssure Ind.

Cas Decay Tank IEI (Holdup) Pressure Cas Decay Tank

'E'Holdup)

Pressure Iad.

Cas Decay Tank

'F'Holdup)

Pressure Cas Decay Tank

'F'Holdup)

Pressure Iad.

0 - 100 PSIC 0 to 1502 Des ISn Pressure N/A N/A N/A N/A Note 1

SAS Note 18 Yes Note 15 SAS Note 18 Yes Note 15 SAS Note 18 Yes Note 15 SAS Note 18 Ycs Note 15 SAS Note 18 Yes Note 15 SAS Note 18 Yes Ycs Ycs Ycs Ycs Yes Yes Ycs Yes Yes Yes Yes Yes D2 VENIIIATIONSYSTEH PPKRCENCY VFNTIIATION DANPER POSITION C.R. Noraal Intake Dauper Postt ton C.R. Euergency Intake Dauper Posttton Open Closed Open Closed Coup ly Cosply Note I Note 8 Note 10 Note 9 N/A N/A Note 13 Note 13 Yes Yes

PARAMETER UNIT SUIBIARY SHEETS Y POINT SIIOOI 40 Of ITEM TAG NO.

VARIABLE DESCRIPTION VENTILATION SYSTEH-EMERCENCY VENPILATION DAMPER POSITION (Continued)

GORY CATE.

EXISTING REQUIRED INSTRUMENTRANGE O.A.

REQUIRE.

MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

POWER DANCE SUPPLY CR TSC EOF OISPLAY LOCATION SCHEDULE/

JUSTIFICATION D3 C.R. Emergency Intake Damper Pos ition Open Closed Open Closed Comply Note 8 Note 9 N/A

. otc 13 SAS Ycs Dll C.R. Recirculating Damper Position Coeply Note 8 Note 9 N/h

. ote 13 D35 3K4 AMP POMER SUPPLIES-STATUS OF STANDBY POVER 4 OTHER ENERCY SOURCES IHPORTANT TO SAFETY Emergency Diesel Ccn.

'A'urrent to Unit 3 Emergency Diesel Ccn.

'A'urrent to Unit 3 D

2 0 - 600 AMPS Comply Note 8 Note 9 N/A Note 13 SAS Yes Ycs Yes 3K4 Emergency Diesel Ccn.

'A'HP Current to Unit 4 Emergency Diesel Cen.

'A'urrenr.

to Unit 4 0

600 AHPS SAS Yes Yes Yes 3K4 VOLTS DC VOLTS 3805 3B06 3B07 3808 3B01 One its Emergency Pover Unit 3 One its Emergency Pover Unit 3 MCC - 3A Bus Voltage MCC - 38 Bus Voltage MCC - 3C Bus Voltage MCC 3D Bus Voltage Load Center 3A Volt Status Load Center 3A Volt Status 0 - 5000 VAC VOLTS 0

600 VOLTS 0 - 600 VOLTS 0

'600 VOLTS 0 - 600 VOLTS 0

600 VOLTS VOLTS VOLTS VOLTS VOLTS VOLTS VOLTS VOLTS VOLTS VOLTS SAS Ycs Yes Yes Ycs o"0 sxso x s ss

~ PARAHETER SIBDIARY SHEETS UNIT 4 TURKEY POINT Sheef of ITEM TAG NQ.

VARIABLE DESCRIPTION TYPE CATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE O.A.

REQUIRE-MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN.

DANCE POWER SUPPLY DISPLAY LOCATION CR TSC FOF SCNEDULEI JUSTIFICATION 3B02 LC3$

3B03 LC3C LC3D 3Y01 3YOI 3Y02 3Y02 3Y04 3Y04 3Y05 3Y05 3Y06 3Y06 3Y07

'Y07 PS-2322 PONER SUPPLIES - STATUS OF STANDBY PONER 4 mHER ENFRCY SOURCES INPORTANT TO SAFETY (Contfnued)

Load Center 3B Volt Status Load Center 3B Volt Status Load Center 3C Volt Status Load Center 3C Volt Status Load Center 3D Volt Status Load Center 3D Volt Status 120 VAC Inverter 3h Current 120 VAC Invcrter 3A Voltage 120 VAC lnvcrter 3B Current 120 VAC Inverter 3B Voltage 120 VAC Inverter A5 Current 120 'VAC lnvcrtcr A5 Voltage 120 VAC Inverter 3C Current 120 VAC Invertcr 3C Voltage 120 VAC Inverter C5 Current 120 VAC Inverter C5 Voltage 120 VAC Inverter 3D Current'20 VAC lnvertcr 3D Voltage N2 Supply for hux. P.'M. Cont.

Valves Pressure T

D 0

600 VOLTS VOLTS 0 - 600 VOLTS VOLTS 0

600 VOLTS VOLTS 0

100 AHPS 0

150 VOLTS 0

100 AHPS 0 - 150 VOLTS 0 - 100 AHPS 0.- 150.VOLTS 0

100 AHPS 0

150 VOLTS 0

100 AHPS 0

150 VOLTS 0 - 100 AHPS 0

150 VOLTS 300 to 2500 PSIC VOLTS VOLTS VOLTS VOLTS VOLTS VOLTS IAHPS VOLTS VOLTS VOLTS AHPS VOLTS VOLTS ANPS VOLTS Pressure Cocaply Note 8 Note 9 N/A Note 13 Note 12 Note 14 SAS Yes Ycs Ycs SAS Yes Yes Yes SAS Yes Ycs Yes SAS Yes Yes SAS Ycs Yes PS 2323 Later N2 S pply for Aux. P.'M. Cont.

Valves Pressure N2 Supply for PORV'S 300 to 2500 PSIC Note 14 otu Zacccu x 9.cia

PARAHETER SIIRARY SHEETS UNIT TURKEY POINI'TEM TAG NO.

VAAIABLE DESCRIPTION GORY CATE.

EXISTING REQUIRED INSTRUMENTRANGE UIRE ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION flEDUN.

DANCE POWER SUPPLY DISPLAY LOCATION SCHEDULE/

JUSTIFICATION CR TSC EOF Sheet 42 of 44 El COSTA INHENT RADIATION CONIAINHENP AREA RADIATION HI RANCE RAD-6311A Ctnt. Hfgh Range Rad.

Honftor Ch.

'A'R-6311A Ctnt. High Range Rad. Honitor Ch. 'A'ecorder RAD-6311B Ctnt. High Range Rad.

Ch.

'8'R-63118 Ctnt. High Range Rad. Honftor Ch. '8'ecorder 10 to 10 R/HR.

I 8/HR to 10 R/HR Cmtr Note 1

Note 8 Note 1

Note 8 Note 10 RAD-6311B RR-6311B RAD 6311A RR-6311A Note 12 SAS Yes Ycs SAS Yes Yes Tes Yes AREA RADIATION - RADIATION EXPOSURE RATE RD-1417 East End of E/H Corridor RD-1418 West End of E/H Corridor RD-1419 Spent Fuel Pft Exhaust RD 1420 Control Roon RD-1415 North End of N/S Corridor RD-1416 South End of H/S Corrfdor RD-1413 Outside Sanpte Rm. - Unit 3 RD-1414 Outside Ssnpte l4a. - Unit 4 10-1 to 103 HR/HR.

10-1 to 104 R/HR.

N/A Note 8 N/A N/A Note 12 SAS Yes Yes Note 25 R-1405 Recorder Yes c'po

~ lxoo.x s as

PARAHETKR NC SUHHARY SHEETS UNIT 4 TURKEY POINT Sheet~ of~

TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

GORY INSTRUMENTRANGE EXISTING REQUIREO Q.A.

REQUIRE-MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REOUN.

POWER OANCE SUPPLY OISPLAV LOCATION CR TSC EOF SCHEOULE/

JUSTIFICATION None AIRBORNE RADIOACTIVE HATKRIA RELEASED FROH PLANT NoBLE OAs 4 vKNT FLoa) RATE Ctat. or Purge Efflueat Ctaat. or Purge Effluent (Flow)

E 10

~Ct/CC to 10 paCt/CC 0

IIOZ Desfgn Flow No Inst. Exists No Inst. Exiscs Noae Resetor Shield Blg. Annulus THIS DESIGN N USED ON TLIIKKY OINT No Inst. Exists Noae None Auxtltsry Butldtag Auxiltsry Bufldtng (Flow) 103 paCi/CC to 10 p,et/CC 0 - IIOZ Desfgn Flow OINT HAS COHHON R ALL INK ABOVE No Ias t. Ext st s No Inst. Exists K6 CONDENSER AIR RKHOVAL SYS.EXN.

RAD-6417 Atr Efeetor Condenser Exh.

Afr Efeetor Coadenser Plow COHHON VERT RAD-6304 Vent Stack N.R. Rsd. Hoattor E

FT-6584 Vent Stsek Flow VENT FROH STKAH CKNKRATOR SAFETY RELIEF VALVE RAD-6426 Sees)a Line Rsd. Hoattor 10 co 10 pCCf/CC 10 to 10 PACt/CC 0

150,000 efa 10 to 10 p.C 1/CC 10 to 10 paCt/CC paCt5CC 0 - IIOE Des tgn Flow 10 to 10 paA: 1/CC N/A N/A N/A Note 8 Note 8 Note 8 N/A N/h N/A N/h N/A Note 12 Note 12 Note 12 SAS Yes Yes Yes Yes Yes Yes Yes Yes No last. Exists FpD ~ )))o) x ra

PARAHETER C SUmRY SNEEIS UNIT 4 TURKEY POINT Sheet <<Of 46 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE GORY CATE.

EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN POWER DANCE SUPPLY DISPLAY LOCATION EOF TSC SCHEDULE/

JUSTIFICATION RD-14 RD-11 PARTICUlATES 6 HALOCENS ALL IDENFIFIED PIANT REISASE POIÃIS Vent Stack htnos.

Contafnnent Atnos ~

0-10 CPS

-3 10 ~ Ci/CC to 10 p Ci/CC N/A N/A N/A N/A Note 12 SAS Ycs Yes RD-12 Containment htnoe.

10 H.

M.D, So.Dade HETEOROLOCY MIND DIRECTION 6 SPEED'STIHATE OF ATHOSPUERIC STABILITY Heteorology 10 Heter 'Mind Direction 0 - 540 0 - 360 N/A N/A N/A N/A Note 12 SAS Ycs Yes 10 H.

M.D.

Turkey Polnt-Hctcorology 10 Heter Mind Direction 60 H.

M.D.

So.Dade 10 H.

'M.S.

So.Dade Heteorology 60 Heter Mind Direction Hctcorology 10 Hctcr Mind Speed 0 - 120 HPH 0 - 50 HPH 10 H.

M.S.

Turkey Point Hcteorology 10 Heter Mind Speed 60 H.

'M.S.

So.Dade Hcteorology 60 Heter 'Mind Speed GPO 33000. a 9 33

0 PARAHET NC SUHNARY SHEETS TURKEY PO INK 0

Sheet ~< oI~

TAG NO.

VARIABLE DESCRIPTION TYPE GORY CATE.

EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE-MENT ENVIRONMENTAL SEISMIC QUALIFICATION QUALIFICATION REDUN.

POWER DANCE SUPPLY DISPLAY LOCATION CR TSC EOF SCHEDULEI JUSTIFICATION Delta T

'A'.D.

Delta

~

BE

'.D.

10 H.

Sigma Theca T.P.

Temp

'A'.D.

HKTKOROLOCY MIND DIRKCIION 6 SPEED'STIMATE OF AIHOSPNKRIC STABILITY (Continued)

Escbaate of Atmos. Stabilicy Estimate of Atmos. Stability Estbsate of Atmos. Stability Estimate of Atmos. Scability Temp.'B'stimate of Atmos. Stability S.D.

-5 to +5 F

-5 co +5 F 0 - 100o 0 - 120F 0

120 F BASED ON VERIICAI EHPERATURE DIFF KRKNCE FROH PRIHARY HETEORO LOGICAL SYSTKH>i

-5 C Co 10oC

( 9 F to 18 F)

ND t 0.15 C

CCURACY PER 50.

HETER INTERVALS

(+ 0.3 F ACCUR CY PER 164-FOtl'NIKRVALS) OR LOCOUS RANCE FOR ALTERNATIVE STABILITY ESTIMATES.

N/A N/A N/A QT'B'ote 12

+T'A'/A Temp

'B'emp

'h'AS Yes Yes 10 H.

Dev PC, S.D.

60 H.

Dev Pc.

S.D.

Kscbsete of Atmos. Stability Estimate of Atmos. Stability 0

120 F 0

120 F Rainfall Escimace of Atmos. Stability S.D.

Direct Solar S.D.

Total Solar S.D.

Estimate of Atmos. Stability Estimate of Atmos. Stability

PARAMETER UNIT SUHHARY SHEETS POINT Sheet 46 ot 46 ITEM TAG NO.

VARIABLE DESCRIPTION TYPE CATE.

GORY EXISTING REQUIRED INSTRUMENTRANGE Q.A.

REQUIRE.

MENT ENVIRONMENTAL QUALIFICATION SEISMIC QUALIFICATION REDUN POWER DANCE SUPPLY DISPLAY LOCATION EOF CR TSC SCHEDULE/

JUSTIFICATION ACCIDENT SAHPLINO CAPABILITY PRIHARY COOIAÃr AND SUHP AK-6372 RCS ActivityCross CPS 10 - 10 CPS 10 ~f/nl to 10 Cf/nl N/A N/A N/A N/h Note I SAS Yes AK-6373 AK-6424 AK 6455 AE 6453 AE-6456 AE-6454 Ctnt. Afr - Isotopic Analysis Cas99a Spectrun Boron hnalyrer RCS Soluble Boron Concentration RCS Chloride Analysis of Primary Coolant.

Dissolved N2 Analysfs of Prfnary Coolant Dissolved 02 Analysis of Prinary Coolant RCS pH Analysis of Prfnary Coolant 10 - 10 CPS 0 - 6000 ppn 0

20 ppn 0 - 1002, of Vol.

0 - 20 ppn 1 - 13 ph Isotopic Analysis 0

6000 ppn 0 - 20 ppn 0 to 2000 CC/kB 0 - 20 pp99 I - 13 ph N/A N/A SEE ITEN B3 N/A N/A N/A N/A, Note 1

SAS Yes Yes CONEAIhHEÃP AIR AE-6307h Ctnc.

N2 Concentration Ch. A

=0 - IOE and 0-20K 0 - 10 Vol. K SEE ITEN C12 None Ctnt. 02 AE-6373 Ctnt. Afr Ca99sa Spectrun AE-6307K Ctnt. 82 Concentration Ch.

B 0 - 10K and 0

2Ã Crab Sasmple 10 10 CPS 0"- 10 Vol. K 0-30Vol. 2 Isotoptc Analysis SEE ITEM C12 SEE ITEN C12 N/h SAS Yes Yes No lost. Exists CPO )XIO) S 9 Si

SECTION VI LIST OF SYSTEMS REQUIRING ADDITIONS, hlODIFICATIONS OR ANALYSIS

The following is a list of the Turkey Point Unit 43 instrument system, which as a result of, this evaluation, requires addition, modification or analysis.

Item B-1 Neutron Flux Two additional redundant safety grade loops for full range neutron flux indication in the control room and in the hot shutdown panel willbe pr ovied for long term accident monitoring capability and to satisfy the requirements of Appendix R (10CFR50) regarding shutdown from outside the control room.

This system will be completely independent of the existing neutron flux detectors and willbe operational during the 1985 r efueling outage.

2.

3.

Item B-15 Containment Isolation Valve Position Indication.

Safety grade limit switches willbe provided for the following containment isolation valves during the 1985 refueling outage:

CV-4658 ARB CV-4668 Ad(B CV-4659 Ad(B CV-2903 CV-2904 CV-2905 CV-2906 CV-2907 CV-2908 CV-2810 CV-2812 CV-2814 FCV-.478 FCV-479 FCV-488 FCV-489 FCV-498 FCV-499 Item B-15 Containment Isolation Valve Position Indication.

Safety grade limit switches willbe provided for the following containment isolaton valves during the next refueling outage:

POV-2601 POV-2603 POV-2604 POV-2605 POV-2606 CV-200 A CV-200B CV-200C

4.

Item B-15 Containment Isolation Valve Position Indication V

The following motor operators will be replaced during the next refueling outage.

hIOV-'866 Ad(B 5.

Item D-13 Pressur izer Heater Status Three ammeters will be added to the control room and indication in SAS/TSC and EOF for the Pressurizer Heater Status by the end of the 1985 refueling outage.

6.

Item D-3 Accumulator Tank Level The following transmitters will be r eplaced by qualified Rosemount Transmitters during the 1985 refueling outage.

LT-920 LT-922 LT-924 LT-926

~

LT-928 LT-830 l

7.

Item A-4 RWST Level E

Two new safety grade completely independent level indication loops willbe provided for RWST level indication in the control room, SAS, TSC and EOF by the next refueling outage.

LT<583 ARB 8.

Item D-11 Pressurizer PORV's position indication Safety grade limitswitches willbe provided for the PORV's during,the next refueling outage P CV-455 C PCV-456 9.

ICCS qualification report willbe available by January 31, 1984.

10.

Item D-18 Steam Generator Pressure Conax seal connectors will be installed for the following pressure transmitters by the end of the next refueling outage:

PT-474 PT-475 PT-476 PT-484 PT-485 PT-486 PT-494 PT-495 PT-496

SECTION VII REFERENCES

REFERENCES Regulatory Guide 1.97, Rev. 3 10 CFR 50.49 Regulatory Guide 1.89 Regulatory Guide 1.100 NUREG 0737, Supplement 1

NUREG 0588 IEEE-323, 1974 IEEE-344, 1975

SECTION VIII CONCLUSIONS

0 ki