ML17341A884

From kanterella
Jump to navigation Jump to search
Application to Amend Licenses DPR-31 & DPR-41,changing Tech Specs 3.14-2,3.14-3.a & 4.15.3.a.4 Re Operability Requirements of Fire Hose Stations in Vicinity of safety-related Equipment
ML17341A884
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 02/11/1982
From: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
To: Eisenhut D
Office of Nuclear Reactor Regulation
Shared Package
ML17341A885 List:
References
L-82-49, NUDOCS 8202180126
Download: ML17341A884 (8)


Text

REGULATORY IFORHA'T ION DISTRIBUTION S:

EM

('R I OS)

ACCESSION NBR:8202180126 DOC ~ DATE: 82/02/i 1 NOTARI'ZED ~

YES FACIL:50-250 Turkey Point iPl anti "Unit 3i Florida 'Power -and Light C

'50-251 Turkey Point Planti 'Unit 4i Florida 'Power and Light C

AUTH,NAME AUTHOR 'AFFILIATION UHRIGi R ~ E ~

Florida tPower 8 Light Co ~

-REC IP ~ NAME RECIPIENT AFFILIATION EISENHUTiD ~ G.

Division of Licensing

SUBJECT:

Application <<to amend, Licenses OP)"31 8,DPR-Piichariging Tech Specs 3 '4"'2i3 F 14"3.-'a 8 4.15 '~a.4 re operability requirements of fi:re hose <<stations in vicini.ty of safety"related equipment.

DISTRIBUTION CODE:

A0060 lCOPIES iRECEIVED:LTR ENCL J SIZE:.

TITLE: Fire Protection Information, (After Issuance of OP ~ Lic,)

NOTES:

DOCKET ¹ 05000250 05000251 REC IP IENT ID iCQDE/NAME ACTION:

ORB ¹1 BC 01 INTERVAL: ELO

'E 06 NRR NAMBACH 10 NRR/DL DIR

~COPIES

.LTTR ENCL 7

N7 i0 2

2 1

1 1

1 RECIPIENT ID '~CODE/NAME GC NRR F IORAVANT07 N

B 08 REG FILE 04 COP IE.S LTiTR ENCL 1

1 2

2 3

3 1

1 EXTERNAL',

ACRS NRC:POR NT.'I S 09 10 1'0

'02 1

1 1

LPDR NSIC 03 05 1

1 1

1 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 33 ENCL:32

r g

t )

i

~

~,

(I t

- g Cg T

f a

~

P r I'

's~

v>

)~

49 roc sl il 1 l gQ )

~

-. ~,,

l ~

f <<<g lc~

i

~ ~,

,q <<1 1

~

~ '

.s E

y ~

ia

>C>, ),>)

li'",g +

".,f ), 'l~~,,~<,f A

i

( 'l

~ X f

P.O. BOX S29100 MIAMI,FL 33152 yihlllg~

FLORIOA POWER & LIGHTCOMPANY Office of Nuclear Reactor Regulation Attention:

Mr. Darrell G. Eisenhut, Director Division of Licensing U.S. Nuclear Regulatory Commission Washington, D.C. 20555

Dear Mr. Eisenhut:

February 11, 1982 L-82-49 I I:co, e

FEB g ceo~

~ ~genug~ e noe

<Cr Re:

Turkey Point Units 3

8f 4 Docket Nos.

50-250 and 50-251 Proposed License Amendment Fire Hoses In accordance with 10 CFR 50.30, Florida Power and Light Company submits herewith three signed originals and forty copies of a request to amend Appendix A of Facility Operating Licenses DPR-31 and DPR-41.

The purpose of this amendment is to address operabi lity requirements of fire hose stations in the vicinity of safety related equipment as discussed in our letter to Mr. Var ga (L-81-472) dated November 6, 1981.

Our letter was 'in response to Mr. Varga's letter dated September 17, 1981.

The proposed amendment is described below and shown on the accompanying Technical Specitication pages bearing tne date of this letter in the lower right hand corner.

Paqe 3.14-2

~

M

~

Technical Specification 3.14.3.a is changed to require hose stations to be operable or for equivalent capacity hoses to be run to the inoperable location within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> of finding an inoperable hose station.

Paqe 3.14-4 Table 3.14-2 is added to indicate the appropriate hose stations protecting sa fety re 1 a ted a r eas.

Page 4.15-2 Technical Specification

4. 15.3.a.4 is changed to require testing fire hoses at 150 psi or 50 psi above system pressure (whichever is greater ).

ooE 5

8202i80i2h 8202ii-PDR ADOCK 050002SO

f. P PDR.

PEOPLE... SERVING 'PEOPLE

T

~

1

Page 2

Turkey Point Units 3

& 4 Docket Nos. 50-250 and 50-251 Proposed License Amendment Fire. Hoses The proposed amendment has been reviewed and approved by the Turkey Point Plant Nuclear Safety Committee and the Florida Power 8 Light Company Nuclear Review Board.

Very truly yours, Robert E. Uhrig Vice President Advanced Systems 8 Technology REU/PLP/jmm Attachment cc:

J.P.

O'Rei lly, Region II Harold F. Reis, Esquire

4~

r~

~

4

~ ~

STAT" OF FLORXDA

)

)

COUNT:"

OF DADE

)

ss

~

E. A. Adomat being irst duly sworn, deposes and say Tha-'e is Execu tive Vice President Light Comoany, the scensee herein; of Florida Power That he has executed.

the foregoing document; that the state-ments made in this said document are true and correct to the best, of his knowledge, information, and bel'ef, and that he is authorized to execute the document on behalf of said E. A. Adomat Subscribed and sworn to before me this dav of

,S at.

oX Flora a

pc44a at Latgo.

NotsrV Public, Stats o

Odob r 3p.1983 Ny commission exp'res:

M~

Maynat4>>""'"P

'J.OT~~.>Y..PLtBLXC, n and for the County of Dade, I

Ol t