i REGULlAiTORY. I.VFORi>>iATION D~ISTRIBUT~IO>>V>> SYSTEM" (RIDS)

ACCESS I ON" NBR

~

0 29 12'6 0 36 B DOC<a DA>TE'e 82/0 1 /20 lOITARIZED'O/',

F'AC~ILi:5'0-250 Turkey Poli nt>> Pll a'nty Uni t 3e F>>l ori da>> Pbyer a'nd Liight C'0-251 TUr key Potent>> ~lie'nti Uni t 0<= Filori da< P>>ower-ahd Liight>> Cl 05000251'UTH

~ NAME>>

AUTHOR AFFKLII'A~T'ION:

UHRI G'g R:~ E>>~

Fliotri da>> P>>oyer.

5 L!ight>> Co~.,

REC'I P>, N AMEi RKClIPilENiTl AFFiILS ATION'KSENHUT'iD.G>>..

Dii v'i si o>>n os>>

LH censing SUBJECiT:

Suomi ts response to! NRCl quest i ons re saf ety anall ysi s'orl posi tive ~o4eratop:

temo>> coef fici ent>> ope'reit~ion;. "Reload>>

Sa~fety. Efvellualt i oui T4r key Point>>

P~l ant U'n'i t>> 0'i Cecil e 6iRevi'si op<

1-"

e n'" l >>.,

DISTR IBUT~IOAI" CBDEl:

A001S CDP<IES RECE'I VED':LITR>> ""NCLl ~:

SIZEl: ~~++

T~ITLE': 9'enerall" D(i str.i'out i op>> fo,ri ail ter I'ssuance o.f>> Ober sting Llican'se NOWT.ES:

RKCIIPiIENiT<

ID CODEX VAMK)

ACiT~ION'RB 41 BC(

01(

IN~TERNALI:

ELD'RR/DHFS DEPT'QS'R

/

L/ORAB>>

0 gl>>

COPIES LITER ENCL)

'3>>

13 1,

0 1

1.

0 1.

1.

RECAP IKXrl ID/ CODEr/~VAMEI IEl 06 NRR'/DLI DER iVRR/DS I /RABI COP'IE8 LiTTR ENCLI 2

2 1

~

1 1,

1 EXTERNALI:" ACRS'RC( PORl VT>IS QQQ2'0 10, LPDR.

1, 1

NS I Cl 1

1 03>>

05<

1.

1 1",

1 TOTALr NU4lBKR 0;-~ COPirKS~REQ>>JIRKO;- LrTR 35

'E>>VCLt, 33

J

<I l

tl

~

1 f

~

4

P.O. BOX 529100 MIAMI,F L 33152

~~iigr~

6~

P/Ilswth&

FLORIDAPOWER & LIGHTCOMPANY January 20, 1982 L-82-24 Office of Nuclear Reactor Regulation Attention:

Mr. Darrell G. Eisenhut, Director

. Division of Licensing U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Mr. Eisenhut:

Re:

Turkey Point Unit 3 S

4 Docket Nos.

50-250 and 50-251 Proposed License Amendment Moderator Tem erature Coefficient 8

Pyric, Jjfo 31 9

@a~ ~

1g@

On December 10, 1981 we sent you the subject proposed amendment with an attached safety evaluation (FPL letter L 517).

Mr. Ron Frahm requested clarification concerning this submittal which was discussed by telephone on January 18, 1982.

A formal response is submitted with this letter.

Since the response refers to the Reload Safety Evaluation of Turkey point Unit 4 Cycle 6, a copy of it is also attached.

Very truly yours, Robert E. Uhrig Vice President Advanced Systems S Technology REU/SKM/jc cc:

Mr. J.

P. O'Reilly, Region TX Harold F. Reis, Esquire Attachment 82012gpg~

P Ckf 05000250 PDR <DO h8 820igp PDR PEOPLE... SERVING PEOPLE

4l C

I

FPL Response to the NRC Questions on the Safety Analysis for Positive Moderator Temperature Coefficient Operation for Turkey Point Units 3

E 4

Question :

1 The analysis of the Rod Ejection indicates a peak hot spot clad temperature of 2 2 10-F in the write up while a value of 23 6 7-F is indicated in Table III.

Which is the correct value2

Response

The value of 23 6 7-F indicat ed in Table' II is the correct value.

Question :

2 The analysis of the Rod Ejection concludes that the fuel and clad temperature limits specified in the FSAR are not exceeded Have the limits specified in WCAP 7 5 88 been verified?

Response

In the pre s ent, analysis, the fuel performance values are below the limits specified in WCAP 7 5 88.

Que stion :

3 In the Locked Rotor analysis

, the FSAR quote s a value of 2 5 10-F for peak average pellet temperature What is the corresponding value for the pre s ent ana lysis 2

Response

The peak average pellet temperature during the trans ient calculated for the present analysis is 2 1 3 7-F.

Question :

4 For the Uncontrolled Rod Withdrawal, peak heat flux in the present analysis is much higher than the FSAR value.

Expla in the reasons for this behavior and'he cons equence s.

Response

The FSAR analysis is based on a reactivity ins ert ion rat e of 6 OX10-5 delta -k/s ec while the present analysis is based on a reactivity insertion rate of 7 5Xl0- 5 de 1ta -k/s ec.

Also the doppler power defect and prompt neutron lifetime are different from the FSAR values

( see Unit 4, Cycle 6

RSE ).

The following description of this acc ident analysis is provided to adequate ly address the que stion.

The description refers to figures 2,

3 S

4 of the sub ject submittal.

0

Control Rod Withdrawal From a Subcritical Condition I

INTRODUCTION A control rod assembly withdrawal incident when the reactor is subcritical results in an uncontrolled addition of reactivity leading to a power excursion (Section 14.1.1 of the FSAR).

The nuclear power response is characterized by a very fast rise terminated by the reactivity feedback of the negative fuel temperature coefficient.

The power excursion causes a heatup of the moderator and fuel.

The reactivity addition due to a positive moderator coeffic-ient could result in increases in peak heat flux, peak

fuel, and clad temperatures.

The time the core is critical before a reactor trip is very, short so that the coolant temperature does not increase significantly.

Hence, the effect of a positive moderator coefficient is small.

II METHOD OF ANALYSIS The analysis was performed in Unit 4 Cycle 6

RSE for a reactivity insertion rate of 75X10-5 delta-k/sec.

This reactivity insertion rate assumed is greater than that for the simultaneous withdrawal of the combination of the two sequential contxol banks having the greatest combined worth at maximum speed (45 inches/minute).

A constant moderator temperature coefficient of +5 pcm/degrees-F was used in the analysis.

The digital computer codes, ini-tial power level, and reactor trip instrument delays and setpoint errors used in the analysis were the same as used in the

FSAR, subsequent safety analyses, and WCAP-8284 Rev.

2, (Florida Power and Light Turkey Point Units 3

and 4

Precautions, limitations, and Setpoints).

III RESULTS AND CONCLUSIONS The nuclear power, coolant temperature, heat flux, fuel average temperature, and clad temperature versus time for a

75 X 10-5 delta-k/sec insertion rate are shown in Figures 2 through 4.

This insertion rate, coupled with a positive moderator temperature coefficient of +5 pcm/degrees-F, yields a peak heat flux which does not exceed the nominal value.

Taking into account the conservative assumptions with which the accident has been analyzed, it is concluded that in the unlikely event of a control rod withdrawal acci-

dent, the core and reactor coolant systems are not adversely affected since the thermal power reached is less than the nominal value. and the core water 'temperature reached is 564 degrees-F compared to 577 degrees-F for the nominal conditions.

These conditions (subcooled coolant,,

less than nominal heat flux) show that the minimum DNBR is well above 1.30.

No damage could occur to the cladding due to low temperature (less than 650 degrees-F) if com-pared to the melting point (greater than 3200 degrees-F).

~

~