Notice of Deviation from Insp on 810518-22
ML17341A476
Person / Time
Site: Turkey Point  
Issue date: 06/25/1981
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML17341A472 List:
References
50-250-81-12, 50-251-81-12, NUDOCS 8109010267
Download: ML17341A476 (2)


Text

'

APPENDIX A NOTICE OF DEVIATION Florida Power and Light Company Turkey Point 3 and 4

Docket Nos. 50-250 and 50-251 License Nos.

DPR-31 and DPR-41 Based on the results of the NRC inspection conducted on May 18-22, 1981, certain of your activities appear to deviate from your commitment to the Commission as

'indicated below.

Your letter of September 23, 1980, indicated that a preventive maintenance program had been established for the containment purge exhaust filters in response to a significant weakness identified in youi radiation protection program during the Health Physics Appraisal conducted May 5-16, 1980.

In addition, you stated that a portion of the containment purge exhaust filters had been replaced and the remaining filters were scheduled to be replaced shortly thereafter.

'Contrary to the

above, on May 20,
1981, the containment purge exhaust filters were found not to have been
replaced, nor had a prevent'ive main-tenance program been established to inspect and change as appropriate the containment purge exhaust filters.

The significance of operating the containment purge exhaust through filters in an unacceptable condition was emphasized in our letter of August 28, 1980.

The inadequate maintenance of these filters directly contributed to the contamination fo'und in the southeast sector of the plant during the Health Physics Appraisal.

PDR 6~ ei08>Z, I 81090 8

ADOCK 050002'SO P~DR