ML17339A269

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Repts 50-250/79-27 & 50-251/79-27 on 790829-31 & Notice of Violation
ML17339A269
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 09/21/1979
From: Sutherland J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
Shared Package
ML17339A265 List:
References
NUDOCS 7911150089
Download: ML17339A269 (4)


See also: IR 05000250/1979027

Text

y

~R RED

~4

"o

O

0

~O

++*++

UNITEDSTATES

NUCLEAR REGULATORYCOMMISSION

REGION II

101 MARIETTAST., N.W., SUITE 3100

ATLANTA,GEO RG IA30303

In Reply Refer To:

RII:RWZ

50-250/79-27.

50-251/79-27

SEP

2 1 1979

Florida Power and Light Company

ATTN:

R. E. Uhrig, Vice President

P. 0. Box 529100

Miami, FL

33152

Gentlemen:

This refers

to the inspection

conducted

by R.

W. Zavadoski of this office on

August 29-31,

1979,

of activities

authorized

by

NRC Operating

License

Nos.

DPR-31

and

DPR-41 for the Turkey Point facility, and to the discussion of our

findings held with H. E. Yaeger, Plant Manager at the conclusion of the inspection.

The inspection

was

an examination of the activities conducted

under your license

as they relate to radiation safety

and to compliance with the Commission's

rules

and regulations

and the conditions of your license.

The inspection consisted of

selective

examinations of procedures

and representative

records,

interviews with

personnel,

and observations

by the inspector.

During the inspection, it was

found that certain activities under your license

appear to be in noncompliance with NRC requirements.

These items

and references

to pertinent requirements

are listed in the Notice of Violation enclosed herewith

as Appendix A.

This notice is sent to you pursuant to the provisions of Section

2.201 of the NRC's "Rules of Practice," Part 2, Title 10, Code of Federal Regula-

tions.

Section 2.201 requires

you to submit to this office, within 20 days of

your receipt of this notice, a'written statement or explanation in reply including:

(1) corrective steps

which have been taken by you and the results

achieved;

(2)

corrective steps

which will be taken to avoid further noncompliance;

and (3) the

date when full compliance will be achieved.

In accordance

with Section 2.790 of the NRC's "Rules of Practice," Part 2, Title

10, Code of Federal Regulations,

a copy of this letter and the enclosed inspection

report will be placed in the NRC's Public Document

Room. If this report contains

any information that you (or your contractor) believe to be proprietary, it is

necessary

that you make

a written application within 20 days to this office to

withhold such information from public disclosure.

Any such application must

include

a full statement of the reasons

on the basis of which it is claimed that

the

information is proprietary,

and

should

be prepared

so that proprietary

information identified in the application is contained in a separate

part of the

document. If we do not hear from you in this regard within the specified period,

the-report willbe placed in the Public Document Room.

79111 5Q + Q

SEP 21 1979

'lorida

Power and Light Company

Should you have any questions

concerning this letter,

we will be glad to discuss

them with you.

Sincerely,

Fuel Facility and Materials

Safety Branch

Enclosures:

1.

Appendix A, Notice of Violation

2.

Inspection Report Nos. 50-250/79-27,

and 50-251/79-27

cc w/encl:

H. E. Yaeger, Plant Manager

P. 0.

Box 013100

Miami, FL

33101

pal