ACCEI ERA DOCUMENT DIST %UTION SYSTEM REGULA Y INFORMATION DISTRIBUTIO YSTEM (RIDS)

ACCESSION NBR:9303030283 DOC.DATE: 93/02/22 NOTARIZED-NO DOCKET FACIL:50-315 Donald C.

Cook Nuclear Power Plant, Unit 1, Indiana M

05000315 50-316 Donald C..Cook Nuclear Power Plant, Unit 2, Indiana M

05000316 AUTH.NAME AUTHOR AFFILIATION FITZpATRICK,E.

Indiana Michigan power Co. (formerly Indiana

& Michigan Ele RECIP.NAME RECIPIENT AFFILIATION MURLEYPT.E.

Document Control Branch (Document Control Desk)

RECIPIENT ID CODE/NAME DEAN,W

SUBJECT:

Forwards "1992 Annual Operating Rept"

& "Unit 1 SG 1992 ISI Rept." ISI rept addresses personnel exposure,SG ISI results, I

challenges to power-operated relief

& safety valves

& info re I-131 reactor coolant activity.

4 DISTRIBUTION CODE:

IE47D COPIES RECEIVED:LTRf ENCLl SIZE: 3 +E9$

TITLE: 50.59 Annual Report of Changes, Tests or Experiments Made W out Approv NOTES:

RECIPIENT COPIES COPIES ID CODE/NAME LTTR ENCL LTTR ENCL I

PD3-1 PD 1

0 2

.2 INTERNAL: AEOD/DOA NRR/DRCH/HHFB RGN3 FILE 01 EXTERNAL: NRC PDR 1

1 1

1 1

1 1

1 TPAB EG FILE 02 NSIC 1

1 1

1 1

1 4L NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTEI CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 504-2065) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISIS FOR DOCUMENTS YOU DON'T NEED)

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 10 ENCL 9

tndiana h6cNga~

Power Company~

P.O. Box 16631 Coiumbus, OH 43216 INDIANA NICHIGAN POWER AEP: NRC: 1147C Donald C.

Cook Nuclear Plant Units 1 and 2

Docket Nos. 50-315 and 50-316 License Nos.

DPR-58 and DPR-74 ANNUAL OPERATING REPORT U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555 Attn:

T. E. Murley February 26, 1993

Dear Dr. Murley:

Paragraph 6.9.1.5 of the Donald C.

Cook Nuclear Plant Technical Specifications requires that an annual report be submitted to address personnel exposure, steam generator in-service inspection

results, challenges to power-operated relief and safety valves, and information regarding I-131 reactor coolant activity.

In

addition, 10 CFR 50.59(b)(2) requires submittal of an annual report describing
changes, tests, and experiments made in the preceding year.

Consistent with these requirements, attached are two copies of the Cook Nuclear Plant 1992 Annual Operating Report.

Sincerely, E. E. Fitz trick Vice President edg Attachment/Enclosure CC A. A. Blind - Bridgman, w/o encl.

J.

R. Padgett, w/o encl.

G. Charnoff, w/o encl.

NFEM Section Chief, w/o encl.

A. B. Davis - Region III, w/encl.

NRC Resident Inspector

- Bridgman, w/o encl.

'6"~'C'1 303030283 930226 PDR ADOCK 050003i5 PDR

Dr. T. E. Murley AEP'NRC:1147C bc:

S. J. Brewer, w/o encl.

D. H. Malin/K. J. Toth/W..R. Moran, w/o encl.

M. L. Horvath - Bridgman, w/o encl.

J.

B. Shinnock, w/o encl.

W.

G. Smith, Jr., w/o encl.

W. M. Dean, NRC - Washington, D.C., w/encl.

AEP:NRC:1147C DC-N-6015.1

ATTACHMENT TO AEP:NRC: 1147C DONALD C.

COOK NUCLEAR PLANT 1992 ANNUAL OPERATING REPORT

0 N