ATTACHMENT 2 TO AEP:NRC: 1039B REVISED PAGES FOR THE DONALD C.
COOK NUCLEAR PLANT UNIT NO.
1 AND UNIT NO.
2 TECHNICAL SPECIFICATIONS 9006280347 900625 PDR ADOCK 05000315 P
ADMINISTRATIVE CO OLS
- 6. 11 RADIATION PROTECTION PROGRAM Procedures for personnel radiation protection shall be prepared consistent with the requirements of 10 CFR Part 20 and shall be
- approved, maintained and adhered to for all operations involving personnel radiation exposure.
- 6. 12 HIGH RADIATION AREA
- 6. 12. 1 In lieu of the "control device" or "alarm signal" required by paragraph 20.203(c)(2) of 10 CFR 20, each high radiation area in which the intensity of radiation is 1000 mrem/hr or less shall be barricaded and conspicuously posted as a high radiation area and entrance thereto shall be controlled by requiring issuance of a Radiation Work Permit*.
Any individual or group of individuals permitted to enter such areas shall be provided with or accompanied by one or more of the following:
a.
A radiation monitoring device which continuously indicates the radiation dose rate in the area.
b.
A radiation monitoring device which continuously integrates the radiation dose rate in the area and alarms when a preset integrated dose is received.
Entry into such areas with this monitoring device may be made after the dose rate level in the area has been established and personnel have been made aware of it.
c ~
An individual qualified in radiation protection procedures who is equipped with a radiation dose rate monitoring device.
This individual shall be responsible for providing position control over the activities within the area and shall perform periodic radiation surveillance at the frequency specified by the facility Health Physicist in the Radiation Work Permit.
- 6. 12.2 The requirements of 6. 12. 1 shall also apply to each high radiation area in which the intensity of radiation is greater than 1000 mrem/hr.
When possible, locked doors shall be provided to prevent I
unauthorized entry into such areas, and the keys shall be maintained under the administrative control of the Shift Supervisor on duty and/or the Plant Health Physicist (Plant Radiation Protection Supervisor).
In the event that it is not possible or practicable to provide locked doors due to area size or configuration, the area shall be roped off, conspicuously posted and a flashing light shall be activated as a
warning device.
- Health Physics (Radiation Protection) personnel shall be exempt from the RWP issuance requirement during the performance of their assigned radiation protection duties, provided they comply with approved radiation protection procedures for entry into high radiation areas.
D.
C.
COOK - UNIT 2 6-21 Amendment No.
ADMINI STRATIVE CO OLS
- 6. 11 RADIATION PROTECTION PROGRAM Procedures for personnel radiation protection shall be prepared consistent with the requirements of 10 CFR Part 20 and shall be
- approved, mai.ntained and adhered to for all operations involving personnel radiation exposure.
6.12 HIGH RADIATION AREA
- 6. 12. 1 In lieu of the "control device" or "alarm signal" required by paragraph 20.203(c)(2) of 10 CFR 20, each high radiation area in which the intensity of radiation is 1000 mrem/hr or less shall be barricaded and conspicuously posted as a high radiation area and entrance thereto shall be controlled by requiring issuance of a Radiation Work Permit*.
Any individual or group of individuals permitted to enter such areas shall be provided with or accompanied by one or more of the following:
a.
A radiation monitoring device which continuously indicates the radiation dose rate in the area.
b.
A radiation monitoring device which continuously integrates the radiation dose rate in the area and alarms when a preset integrated dose is received.
Entry into such areas with this monitoring device may be made after the dose rate level in the area has been established and personnel have been made aware of it.
c.
An individual qualified in radiation protection procedures who is equipped with a radiation dose rate monitoring device.
This individual shall be responsible for providing positive control over the activities within the area and shall perform
. periodic radiation surveillance at the frequency specified by the facility Health Physicist in the Radiation Work Permit.
- 6. 12.2 The requirements of 6. 12. 1 shall also apply to each high radiation area in which the intensity of radiation is greater than 1000 mrem/hr.
When possible, locked doors shall be provided to prevent unauthorized entry into such areas, and the keys shall be maintained under the administrative control of the Shift Supervisor on duty and/or the Plant Health Physicist (Plant Radiation Protection Supervisor).
In the event that it is not possible or practicable to provide locked doors due to area size or configuration, the area shall be roped off, conspicuously posted and a flashing light shall be activated as a
warning device.
- Health Physics (Radiation Protection) personnel shall be exempt from the RWP issuance requirement during the performance of their assigned radiation protection duties, provided they comply with approved radiation protection procedures for entry into high radiation areas.
D.
C.
COOK - UNIT 1
Amendment No.