Text

ATTACHMENT TO AEP:NRC:1071G PROPOSED CHANGES TO LICENSE CONDITION 9003

~K pgpp031g 150205 900~06 F'I3R pgg

r yi

Docket 'No.

315 Page 4 of 6 Amendment No.

31 2.C(4)

The licensee may proceed with and is required to complete the modifications identified in Table 1 of the Fire Protection Safety Evaluation Report for the Donald C.

Cook Nuclear Plant dated June 4, 1979.

These modifications shall be completed in accordance with the dates contained in Table 1 of that SER or Supplements thereto.

Administrative controls for fire protection as described in the licensee's submittals dated January 31, 1977 and October 27, 1977 shall be implemented and maintained.

(5)

S ent Fuel Pool Stora e

Amendment No.

The licensee is authorized to store D.

C.

Cook, Unit 1 and Unit 2 fuel assemblies, new or irradiated in any combination up to a total of 2050 fuel assemblies in the shared spent fuel pool at the Donald C.

Cook Nuclear Plant subject to the following conditions:

Fuel stored in the spent fuel pool shall not have an enrichment greater than 4.95/ Uranium-235.

>>2.D (6)

Deleted by Amendment 80.

Ph sical Protection Amendment No.

122 The licensee shall fully implement and maintain in effect all provisions of the Commission-approved physical security, guard training and qualification, and safeguards contingency plans including amendments made pursuant to provisions of the Miscellaneous Amendments and Search Requirements revisions to 10 CFR 73.55 (51 FR 27817 and 27822) and to the authority of 10 CFR 50.,90 and 10 CFR 50.54(p).

The plans, which contain Safeguards Information protected under 10 CFR 73.21, are entitled:

"Donald C.

Cook Nuclear Plant Security Plan," with revisions submitted through July 21, 1988; "Donald C.

Cook Nuclear Plant Training and Qualification Plan," with revisions submitted through December 18, 1986; and "Donald G.

Cook Nuclear Plant Safeguards Contingency Plan," with revisions submitted through June 10, 1988.

Changes made in accordance with 10 CFR 73.55 shall be implemented in accordance with the schedule set forth therein.

~ ~

j p('I ~

D5cke't No.

316 Page 6 of 11 (q)

Deleted by Amendment 2.

(r)

Deleted by Amendment 68".

(s)

S ent Fuel Pool Stora e

Amendment No.

The licensee is authorized to store D.

C.

Cook, Unit 1 and Unit 2 fuel assemblies, new or irradiated in any combination, up to a total of 2050 fuel assemblies in the shared spent fuel pool at the Donald C.

Cook Nuclear Plant subject to the following conditions:

Fuel'tored in the spent fuel pool shall not have an enrichment greater than 4.95K Uranium-235.

  • Amendment 3 deleted Paragraph (s),

Amendment 13 added a.

new Paragraph (s).

2.C.(7)

Deleted by Amendment 63.

Secondar Water Chemistr Monitorin Pro ram The licensee shall implement a secondary water chemistry monitoring program to inhibit steam generator tube degradation.

This program shall be described in the station chemistry manual and shall include:

1.

Identification of a sampling schedule for the critical parameters and control points for these parameters; 2.

Identification of the procedures used to measure the values of the critical parameters; 3.

Identification of process sampling points; Amendment No.

18 4.

Procedure'or the recording and management of data; 5.

Procedures defining corrective actions for off control point chemistry conditions; and 6.

A procedure identifying (a) the authority responsible for the interpretation of the data, and (b) the sequence and timing of administrative events required to initiate corrective actions.

0

~

~