05000315/LER-1979-056-03, /03L-0 on 791027,opening Torque on Two Ice Condenser Lower Inlet Doors Exceeded Max Tech Spec Limit. Caused by Door Springs Slightly Stiffer than Doors on Other Bays.Spring Tension Bolts Adjusted

From kanterella
(Redirected from ML17318A471)
Jump to navigation Jump to search
/03L-0 on 791027,opening Torque on Two Ice Condenser Lower Inlet Doors Exceeded Max Tech Spec Limit. Caused by Door Springs Slightly Stiffer than Doors on Other Bays.Spring Tension Bolts Adjusted
ML17318A471
Person / Time
Site: Cook 
Issue date: 11/26/1979
From: Delong S
INDIANA MICHIGAN POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML17318A470 List:
References
LER-79-056-03L, LER-79-56-3L, NUDOCS 7912040390
Download: ML17318A471 (2)


LER-1979-056, /03L-0 on 791027,opening Torque on Two Ice Condenser Lower Inlet Doors Exceeded Max Tech Spec Limit. Caused by Door Springs Slightly Stiffer than Doors on Other Bays.Spring Tension Bolts Adjusted
Event date:
Report date:
3151979056R03 - NRC Website

text

1 2

1 1.

ii i

i i

02. NRC. PDR 1i MPA i5 NOIAK/KNIELI 17 AD'OR ENGR i9 ICC 8YS 8A 22 RKAC. SAFT BR 24 RAEGER 26 AD/SITE 'ANAL:

28 ACDKNT~ AALYS E JORDAN/IEi

"'TS GROUP LKADR 1

3 3

1.

1 i.

i i-ii i

i 14 TAiKDO 16

EEB, i8 PC'ANT SYS BR 20 au PCaVV-Sys 23 EAGA"BR 25 f HR SYS BR OPERA'.,"$ >>IC," BR 29 AOR SYS

'BR'ANAOERgS TMI~H STREET i

i, t ~

A ~

~ f ~

REGULATOR>>VFORMATION DISTRIBUTION S EM (RIDS)

ACCESSION NBR:7912040390 DOC'e DATE; 79/11/26 NOTARIZED e NO DOCKE~T FACIL'b0 3i5: Oonel'0 O'., Conc Nucl eer Power Pl anti 'Oni t ii Indiana 8

0500lI315 AD'fH ~ NA'ME AUTHOR "AFFILlATION DELONGiS,O, In3f,ana, L Hicliigan Power Co,.

AEtE P ~ AAME,

. REL'1P IENTl AKFILI A T ION Beg,ion 3i=- Ch'i'cago'i""Office of the Di>>rector

SUBJECT:

LER.79 056/03Li~:on 791027~opening torque on two>>ice condenser=

lower-inlet doors <<exceeded max Tech Spec>>')imit>,

Caused by door'prings slight>>iy stiffer< tlian doors on, other.

beys, Spring tension bo.its.adjusted.

DISTRIBUTION CODE:

A002$

COPIES RECEIVED:LTR

~ ENCL<

SIZE'i ric. 'nt" epon s

>>toTvs:.~ = 3=+MQ~SZI

'RECIPIENT>>

COPIES RECIPIENT" "COPIES

.ID CODEiNAMK LII'tR. ENCL.

-.IO CUbEiNAME LTTA"EACLI ACT,IOt>>;

05 BC','Q>>>>8+"/

ll,,

"">>I" INTERNAL; EG'IL EXTERNAL' 03

LPDR, 29 ACeS 1

1, 16 16 04'SIC 1

1 Zl s(

TOTAL NUtIBER OF COPIES REQUIRED',L>>TTR PS'NCL>>

4 I

f I t9 l1 4

~

v r

C I

1 e

~~ l 1

P ll I