ML17318A470

From kanterella
Jump to navigation Jump to search
Forwards LER 79-056/03L-0
Date released: 05/31/2018 Download: ML17318A470


LER 79-056/03L-0 on 791027,opening Torque on Two Ice Condenser Lower Inlet Doors Exceeded Max Tech Spec Limit. Caused by Door Springs Slightly Stiffer than Doors on Other Bays.Spring Tension Bolts Adjusted
ML17318A471
Person / Time
Site: Cook 
Issue date: 11/26/1979
From: Delong S
INDIANA MICHIGAN POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17318A471 (2)
Forwards LER 79-056/03L-0
ML17318A469
Person / Time
Site: Cook 
Issue date: 11/26/1979
From: Shaller D
INDIANA MICHIGAN POWER CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17318A469 (5)