GENERATOR CURRENT TR IP NO 74GD GEN -XFMR CURRENT TRIP NO 74GT UNIT 2 XFMR DELUGE SYS LOCAL ALARM No TSR,RSR TSX ACV C-1 GENERATOR GROUND TRIP C-2 883 No 74GG/883, 74GG/865 883 Ov GENERATOR NEG SEQ TRIP C-11 C-12 1113 885 NO 74NS, 94NS GENERATOR NEGATIVE SEQUENCE C-21 C-22 2.
'98 853 NO 46A 4oALX 111 3 GENERATOR TURB INE TRIP No 74T/883 GE.v ILIAia'T o R I=XC 1 TA,F10 N GuPPLY
- BRING, TR IP No AFET c.ERE RECTO R
UOLTE/HERTZ HI C. H Te I I b S-I,2.,74OE, 94OE No OY GENERATOR C-3 883 No 74GF FIELD FAILURE TRIP C-1 875 C-23 No
/4/oXI -I GE.NEiZAT0 fZ VOLTA.GE'. RF4
~
TRANK' R TO Mb.Q UAL NO 94/RB C,C~ E ERATO~
EXC I TATlokl Sxi TCHGEAR TRIP c-4 885 C-1 875 C-2 NO 74-21 GENERATOR No 74LB OCB FA ILURE /
B/U TRIP GEN BKR 8W26 TRIP NQ 52,83/1E GEN OCB GENERATOR DISTANCE B/U TRIP Ov NOTES:
y YELLOW WINDOW (NOT ENGRAVED) 2.
FOR TYPICAL ANNUNCIATOR WINDOW DESCRIPTION SEE SHEET 802 I
R
" MULTIPLE ALARM INPUT WITH REFLASH CAPABILITY THIS IS A TEMPORARY INSTALLA-T ION PEND ING COMP LETION OF UNIT 2 QdPjX-I, P5X-Z, LOTXt, LOTXZ, LOTXS, BI=PDI; BFPD2,4I TD, LOP KIRIL&CKTS I(2,EOT CSEE S WITC'IIYAR-D nAc
. F-tl 828, SH.2 C-5 882 O
885 C-25 886 GENERATOR LCKOUT RLY FAILURE No C
1-1 1213 GENERATOR POTENTIAL TRANSFORMER C-31 FA ILURE 882 NO 60YA 60XB C-32 885 GENERATOR vox +/HERTZ H IGH LIMIT No VHL,FP X C-33 872 EXC ITATION
'5W )TCH&C b Ic.'IVOLI E LK F
)Fc
~B Fl DI)
No PFPD2 C-3 8W30 TRIP No 52
~ 83/ IM 5
C-35 886 NO GENERATOR ISOL PHS BUS COOLER TROUBLE R
c No AC-41-1/866 GENERATOR ISOL PHS BUS TEMP H IGH
-i%A & B c-41 I-EM, l=iELD
- GRD, DCT. /
gk'US I-I COklTRI-T FZ ILuer C-51 GENE RATOR ISOL PHS BUS IIYDROGEN DET/FAIL 865 NO R1, R2 865 No 64xk, BORAX c-42 872 No IvfX'L C-5 865 GENERATOR
~AX I M U I'4 EX'C I TATI 0 ki LIP IT C-43 875 EXCITER COOLER AIR TEMP H IGH C-53 NO TR-2.2.-30, PTS 11, 12 890 E XC.) TATIO4 SKI TCH GEA R.
LOSS OF BWCKLIP NO GENERATOR FI E LP FOLIC I Q q No FORCING ALARM c-4 872 c-54 875 No GEN BKRS 8W26/8W30 TROUBLE q-45 No 63X lE-IM 5 884 c c QE'EATON MI8 I MU 'M E'XC ITA'T108 HKlX 875 EAR RECORDS NUCL DOCUMENT@)NTROLCENTER lA-PC M BS IBZ aIS-PC.M O7~- l94 8IZ-F'CVI O40- IES Pl I-PClvl 04Z.-IS& F Rlo-pic.H ooo-ooo.
>ol Re -Pc-M 106-.18&
RB-PCS Sb(
lI-tS IU-REDR,AHA R,S-PCA-55=80.
~1.
p,r-e F I--l30-I R4-PCS-..e -80 Icf Fails& f~
9-7-'7 I 2..
10~0-'IP C
I 7-IZ..S~
REV DATE BY PPROVED IO 6-e-V9 REV II.2Z 5 8 DATE KC.H BY APPROVED aw.~IC a~. '
semis ~
cH, oars l~+
29 197I APP VKD EBASCO SERVICES INCORPORATED NEW YORK FLORIDA POWER 8I L I GHT CO.
HUTGHINSON ISLAND PLANT":UNITNO I CONTROL WIRING DIAGRAM GENERATOR, MAIN & AUX TRANSF ANNUNCIATOR-C SH, 1 RTGB-101 8770-8-327 SIIas~ 86 I