Tornado Missile Protection Diesel Building Mas.Sheet 1
ML17312A056
Person / Time
Site: Saint Lucie 
Issue date: 01/06/1976
From:
EBASCO SERVICES, INC.
To:
Shared Package
ML17312A008 List: ... further results
References
8770-G-702, NUDOCS 9702040186
Download: ML17312A056 (1)


Text

A 8770 -

G 702

'X m I..,.

..,~~I~ OIL SEP RATING i C3v ll 'K>>

A BOX564 54-1 10 12 13 14 15 17 18 19 A

D E

"F OI EXI5T 24SW LINE EL.I4.08'.2 CLASS I CQIIDUITS,

EL. 14.50', Rovio6 ROT 45 PBR Et D'14

'103/Mtt)

E 1748.00 1-0

/THRUST BLOCK To c-rCJ

~+% LINE EI: 14.08'1-0 HELQ ATRO 135

-Z CLAS52 COH L 14 5O'icovtoo PER Det'O'Cet.'1 STJZ8FP EL. 15. 50

~34 5TQRM DRAIN PROT A5 03/M t t) r-a FGR ALUM FLAsHIN6,

'566 DET C'(M 8)

DYJC2 ir103 EL49.00

  • r COLLAR 1 c 4' I

3-6

~EL 55 42 Og

'10.

ca 2 6 ID PIPE Ect'o, 8 EL 47.33 ekeeve wire coLLAR FCELO)

EL.40.08 (VYP)

LP" 48.'32 EL 48.50 1'OR JLUIU FLASHttcc 5ei Sl.l DETL'6 (L6)

DWC 6 '103 OUVER PROTECTIO 6 L 4'1. 50 EXISTING WALL

'3l 0.67r)117 o

UP REMOVE EXI5T -~

pos. (JUAHo RaiL I

I"I PEQUIRED i

I

~

i RELOCATE c)

CATCH BASIN438

=

= D'>>6 6-483 IN r.'3 Io Q Ji B)VO)tot~

0 I

?

PEr UELING I

Cpt QP G.o G!

y II' io-3 Rio ll"-

CCNOI ECIE>>

I N

tni<<F ro JCCOI 45 KEO'JiKBO )

(L t6) 4

'25.50

23. 50 J

I EXIST Cootcowe>>Y CGGLCH6 PUMP Ol96

--li--I-)

IJ L

CO'2 ekUH FLASHING 55>> 5IM Dc YL."8(L61 DWGC 6-703 LDRILL IN DVI'L ) GROUT (TYP)

FOR DET SEE DWG 5170 G 705

FIELD TQ CLEAR EXIST REINF SEE DWG 8770-G-O'12

)Y 673

... 'XISTING WALL HP EL 2'2.58 G-B-20 EL It>>00 EL. 10.00 AS BUILT DRAWING TRANSFERRED TO F P L o-~o:i /

RSYC (N2, '4 9 I NS,kl993)5)MAS VJp TO AS-Butef,toWiioi'I RCV ivt,Got,at NS 0

I J.I/.75 tJ4,35,35)okoN aoo ie)ker Uo CC io9>> ) QIY ilielkiotes 5,5.

7). C.

itie

-O.

ROTECTIQN ALL (Iiz) Fl

$214 ETQRcc DRAIN 2 ISOLATION ZDRH 2-547 DRAIR OR EQUAL ( 3 C l. Pipe (SY FIELD)

(YYP)

CJ roR 21HASGJIG 6 JOtNV 5\\ALAN'2 596 DRYL 9 Dwe 6)103(KM) a CFOR DET. OF EMBEDDED

'Z 6 REMOVABLE DOOR SEE A-5 DWG 81 70-G -8'36 503 0

I

., 'EL.15.3C 1

i ti:I EL.IS.GCJ 2'-9 ',

ZBL6 5-04

'(clo) 29'-0

,'/

20- 0 EQR LOUVERS I.

LOUVER PROTERON JOINT LP OIL 5.5. 64 L-EL~

H.P OF ROAD EL19.0 3/F T

~T CI ZBCLASS C

Hi CJCTS I

SEE HVACSA.S PROVIDE HECES EMBEDDED 125 FQ HVAC LQUVEFS CI RISC. ITEM5 SEE I I - 0 FOR DFT 0 EMB>>0020 PLS. Fo R LLIHG SHUTT 3 SEE A.51 QWC 817OJ TYPO (LH)

~(G 5 "836.5G3 i

EL;14:50 2 C 2 or'NG DUCTS.to BE A5 PEQUIFED 0'0 0

. 5 cL 22 50 El. I'7.00 CLASS I CQNDUI'15 ( BOXES MOUNTED ON THIS WALL TQ BE R

I.OCATED AS REQUIRED

-P+

334 RCP" 5TORM DRASFr 6 836 <<Go i: LOUYRES J E (T'Ip)

RELOCATED 2 ISOLATION JT ALL AROUND 5EE DETAIL 8 (t(14) DWG G 703 (TYP)

(110) 3-6 IWALL O'I -"

SECTION A A (13)

FOR ALUM FLASHING FP SEE DETAIL E (Lio)

Z DWG G.703 Hp e<<7-58' P

8 '. 47.50 SECTION B-B(c3) 30. 7 II G-B-ZO I SOL 2

/-0

+F 13-0 SECTION C-C(HT)

EXIST i)IE SEL GEM RATOR BLDG 15.50 EL EXI tvp BL 49.00 42 Ct.48.92

(

'k"I 1't EL 4'1.50 5

o:

io 3Y 9

0 co 4

IC6 I 0

li r

/5 4.WM-35 O

3-WM-45 5-PB-45 3

ET" P" (1451 220 0

Z.G WALL SRYOND EXISTING WALL I'-c, HI(

4 B-ZO FiELD YO CU 2 EXIST IADDER 9 SUIT. FOR LADDBK Dev L 686 OWG C -84t (Mi3) ili6) 7o1IGQIILo II 82o 4L0 410 IT Iluo (Kct EXISTlHG WAI L

-0 24

'io 213 RELOCATED AS REQUIRED HQIE. ALL DUCTS TO BE EL22.50'D EL.19.OQ 5 22 EXISTING COMPONENi COOL) IJG PUMP BLDG/

SEE DWG 8770.G-671 ELL25.50 EL.Z3.50 SGF DFV0A" CC. '5 EL 22.5O G.B-ZO EL.IC.OO ROUGHEN EXIST CONC 5LTT.S)

(Iio)

(NIT)

O I

DRAIN

~ GUTki1 U

J ik L

20 3J O

0) 1 c 'I E IGSS.SO ACCX5 kk i 2.

8'V A-S (Elo52.45)

L, XC9 J,X.

(E Io) 0 8" IO 6'I 331 oo\\ tc 0

t 0

110 ISO i'CACN tok JCK C>>Death ooit 6[

P tean tEZIBSTORM DRAIN MCCNCCOLE

~I 12) RCP EL 894 C) o 4-WM-38 3-WM-4S 306COV R

CBJ I'.O CI'-O '2 SPLASH Rkncr.

IO Rt CM OUTLCT E)Y FIELD EXISi 30 PIPE E IG46.62j

')I

'4""I Jt)Li,

/'

I J

i 80 0

CJ I

/

I I I I I

~I.J SECT ION HPEL 48:"JB F (Ct) L~PE 48.50 (H))

SECTION t

( EXIST D)256)

I>> GEAI BLDGI E-E (06)GG)

T IP 6 CLASS I SECTION G-G (c,3) t 2 EL>>9.GD 2

LP EL>>8.92~

EL>>6 60 HPEL;8 4 LP EL 48 ~PC SLOPE(TY )

I,EXIST 304 PIPE (Ej,434. 9 G),

oi SFE DET 5 (HS) DCWG 13 6-667 (TYP)1 tok3 jSF 7 HP EL 3L92 3 o 51422.50 I

')38 TYP H.4L riel -oN Siuo RC ACTQIT AUX SLDC)

'IL REACTOR AUXILIARYBLDG ISOLAiiJ to Joiu 'i JK NCi>>

GJ-I t CU LP CGIJ C SLA.S 4552 EL 226 >

I-IP ELI90

~PI C LLV HANDRAIL SY FiELD) XEL2230 k~F7 EL 22.50-HP EL 22.58 EL 2'2. 50 I

G.o EL 55.42 L

I.QO 1.6 C TO C fAWAY FOR CONC BTRVCTUP'25 FIE(li ltoi TO UBJE P

I

/SN ~

STEEL P ASFGRMS ACPEAOY DUICC CAS RK 5)cck ckatce ro wakia USC 62 0 rh J Boite oh tvc 5004th.Ueikkso tiokcs'tkl.k t!2 keit E

0 rkk cei IF (cvol 6

Itk,j,I23 RCP

'-.')"".';

4 MIIN ETIJAFOAM CM'.'P-

>>LTT.SII(

REMGYE ERELOO EXIST C. B." 38 L

SAC KTIU IVITH Ottk Ckkrox PCKL ELIS OOQ 2 ='Mv

~TYP SECTION L:. 3 SEXIST 1)IBBRL Ir c s M CS LD ce I

D-D( 3)

I" l-o ~

52 Ik'brt Bk>>CK 8 DRAtNooikt'\\

RY FIELD 6-8-ZQ EL IG.OO o<<LL ExiSi SECTION h ~

ELEC DUCT EL,IQ OCI jj I

I I

I I

I I

I I

E)Ei "A'Gl)

TYP FOR LPWALL 33 0

I G

SE CT ION H-H(GI)

Iie 9 2, r-EP 5 RUT 5EAT I TYP)

SECTION LF L (o3)

EXIST DIESEL ceEM '%5LDcv

(- Stteuf STRui

)

(7152 DIESEL GEH tbLDC ICE ACTOR AUX ELDC4 EL T~l.5 D E' 0 ED" (2io)

T Y P FOR I -O 3LAZ)

G L.P fj Ck) gEL 22.6 i

'EL2'(.5 PLACE CYG AG>>.tNST EXIST COIJC BM CUI CB30I ELI9.0 J.Z

. 4 E, 19.0 I:,:

.)',

.', 4 et ELEC Docl ETHAFOAM C Z 150 JT BE7

  • '* FL Io.o

\\V cnuc

4. 0 EL 12.0 6 <<52 Ma>> col.e L"..(1 ETHAFOAM (L

.CJ I

11 (TYPJ II

,I.--tEXIST cne EXI 5'1 So 4

'v, IZBRCp Ptl 6 'TYP

~l,96N, ZL I c 3 (TYP)

~ 5>>E 4

I 4

6 L>>i 5(7,14) D, j03 c

C::::

\\.XiST ckoSS I

cokJDutt5 4

CGSJC Sea 25, ZEX 1ST SO 4 k)D KUI St Alhvrot t 5 (ti9 I'CY

'JRYC192,.D)/

2 Oe,tu)oi'". Icit)

CVA.J;fi3;9;KBY kkt Joo I i,c5!i" 'C,K 91627944 2 ',24,4tat

'".. RFC 6

S.CJC4GLB E)ii5t MASJIJQLE P I PS NUCLEAR SAFETY RELATED 6 27-75 SF CT Iv/I-Ix/I (12

)

SECT P-P (>>)

SECT N N (H7) r ay

-)

I

,~~G

(,~~G 5 tro 0

I.

rj I

n 14 I

I r Y 0

JY 'I30C)91 CCG C,,CG 2

Ct c"9 I

.~ l.

I I

REACTOR AUX. BLDG.

I I

QUANTITIES.(NET BY FIB[

CONCRETE CLASS "AA"(4OOO Pet )

~ICSZO CU YDS 2

ISDLKTtoki JT (84) 8'I r'teLD 3 6 C.l. PIPE 1 ZURN Z-S47 DRAIN OR EQ SV FIELD FOR ctethpoPCCNG BE SAR BENDING SCtt 81)o B 480 4 2-6 ID PIPE. SLEEVE WITH COLLAR (89)

BY FIELD KEY PLAN I:40 D

HAND RAIL (CZ)

BY FIELD ETHAFO" Mi 4 IJORuFLEX-L SEALAut BY FIELD ALUM FLASHING BY FIELD FERALUN NOSINg 8 pJF BY FIELD 4 P WITH 23 HBLBGW VUG545 PCR DETLB 4 S(h5)iSY FIELD LEGEND:

FH-FIRE HYDRANT 5W-SERVICE WATER Do-DIESEL OIL FP-FIRE PPO'tECTION WM-WASTE MANAGEMENT PB-PROCESS BLOWDOWN PRO T P RO T6 C:T I0 IJ B,M

- BEAM. SITE C) T.ES:

ALL CONCRETE SHALL BE CLASS AA (4000 PSI)

SEK SPECIFICATIONS FLO-8770-473 FOR GENERAL NOTE 0 SEC DMIG 8770-G-66 7.

CJHLI5>>

NOTED OTPcpo'TPUCTURE COVEPED PY YHIS DWG 15 SE15MIC CLA55 I, REMOVE EXI5TING CONCRETE / RELOCATE EXISTtNG PIPES ( CABLE CQNDUITS AS REQUIRED.

SUPPORT ALL PIPES TEMPORARILY AS REQUIRED FOR PLACEMENT OF NEW CONCRETE.

RELOCATE RD. AS REQUIRED OH EAST/ WEST SIDES, ALL EXCAVATION TO BE DONE CAREFULLY ALL DIMENSIONS OF MASONRY BELOw CIRADE TO BE VERIFIED BY FIELD AFTER EXCAVATION.

1p' To PRovIDE, H-Rtzoiti A(. cDHslRU YIDN JCItJTS ICJ WA'LL AS REC)D.

ALL HORIZON tAL

'QNSTRtJCTIOH Ior)IT5 SHALL BE ROUGMEBIEC 0

CLEANED FR E OF LAITANCE. VERTICAL CONS.RULTIC

'OINTS 5HALL HAVE A FORMED KEY)r 5>>

Di '5 STI0.G. 703 (LI4)

ALLEXPOSED MSIZSHALLBE ASS STEEL CCCALVANISED AS 2 BR SPEC FLO A

'2 2 83 FOP, TYPICAL DETAIL OF ETHAFOAM PROTECTION Fop( cLA55 I PIPE I coNDuiTs 5EE DETAIL'D'wG 8770-G-103 (MIZ)

FQR REINF DETAILS SEE DWGS G-'103,'704,105(704 REFERENCE DRAWINGS:,

LI>>, tvr I

t 5

8770"A-14to OUTLYING AREAS CONDUIT/I GROUNDIHG 8770 6 380

'YARD PIPI'NG 5H I

8110 G

'CARO PIPING 594 3

81'70 -G -11 2 YARD PiPINCG 5H 4 81 70-Cc - i '1 4 ELECTRICAL MANHOLE DRAINAGE PLAN 8110-6 351 YARD DUCT RUNS AND LIGHTING SH.

I 8770-6-408 ELEC. MANHOLE DETAILS 8110- G-421 DIESEL GENERATOR BLDGCMASOHRY 8710-6-461 SITE GRADING / DRAINAGE SH I 8770 G-483 SITE GRADING ( DRAINAGE 5H Z 8710.G" 484 DIESEL QIL PIPING 87 70 I 6 9 MISCELLANEOUS BLDGS PLUMBIHG (DRAINAGE 8170-G-909 COMPONENT COOLING PUMPS FDN-MAS 8'770. G-671 COMPONENT COOLING PUMPS FDN RRINP 81)D.G.C12 MISSILE BARRIER-OICBCL 62N AREA 8'I'706-836803 BAR SENDING SCHEDULE 8770 54804IA Tvtp-DIESEL IBLDG-M BR SH I

87 )4.6-103 Coi"i>>GNBNT Cookthc 0220. FRAMING (4 3) 8)"G.'.84' D

'Ca RECEIVED JUL 1/" 1977 EBABCO SERVICES BI.lllO2 PLAN)

THIS DOCUMENT IS THE PROPERTY OF EBASCO SERVICES INCORPORATED.

IYS USE 19 EXPRE..SLY RESTRICTED BY THE CRMB OF THE

CONTRACT, DATED AS OF AUGUST tr>>1969, BETWEEN EBASCO SERVICES INCORPORATED AND FLORIDA i POWER 6

LIGHT COMPANY.

FLORIDA POWER 8 LIGHT UGMPANY ST LUCIE PLANT

'9 5-890GGO KW INSTICLI ATION UNIT IJO I

TORNADO ivIISSILE PRPTFCT1ON DIESEL BLDG.MAS SH EBASCO SERVICES INCORPORATED sc ks

.'. =iLo oiv oc RANAIKktG ov DATE /Y(7/ /$

r /)r/J 8770-6 -70 3

ir>>rc co co.

10 I

7F 12 13 14 It>>.

DATE ASYCSCOK ev CK.

17 Jrtcovso CK~ + yYVc 18

/L) (Z t()>~)I-