Category:DRAWINGS
MONTHYEARL-97-323, Vehicle Barrier System.Sheet 491997-11-28028 November 1997 Vehicle Barrier System.Sheet 49 ML17312A0801997-01-17017 January 1997 Control & Block Diagram.Sheet 25 7 ML17312A2221997-01-17017 January 1997 Fire Protection Reactor Auxiliary Bldg El 0.50 Feet Fire Doors Dampers & Sprinkler System ML17312A0811997-01-17017 January 1997 Control & Block Diagram.Sheet 25 8 ML17317A5721997-01-17017 January 1997 Flow Diagram Miscellaneous Sampling Systems.Sheet 2 ML17317A3621997-01-17017 January 1997 Feedwater Control System Block Diagram.Sheet 1 ML17312A0281997-01-17017 January 1997 Electrical Schematic Hutchinson Island.Sheet 1 of 4 ML17312A1751997-01-17017 January 1997 Control Wiring Diagram Device Numbers & Definitions. Sheet 20 ML17319A0591997-01-17017 January 1997 Electrical Schematic Hutchinson Island.Sheet 1 of 2 ML17312A1781997-01-17017 January 1997 Control Wiring Diagram Device Numbers & Definitions. Sheet 21 ML17312A1211996-11-0909 November 1996 Flow Diagram Feedwater & Condensate Systems.Sheet 3 ML17312A2101996-11-0909 November 1996 Flow Diagram Emergency Diesel Generator System Diesel Generator 1A.Sheet ML17317A5561996-11-0606 November 1996 Flow Diagram Firewater Domestic & MAKE-UP Systems.Sheet 1 ML17312A1261996-11-0303 November 1996 Flow Diagram Component Cooling System.Sheet 1 ML17312A1681996-10-22022 October 1996 Florida Power & Light Company ST Lucie Plant 1976 890,000 Kw Installation Unit 1 General Arrangement Fuel Handling Building Plans ML17312A1241996-10-0404 October 1996 Flow Diagram Circulationg & Intake Cooling Water System. Sheet 1 ML17312A2091996-09-19019 September 1996 Flow Diagram Condensate Polisher Filter Demineralizer System.Sheet 2 ML17312A0091996-09-0606 September 1996 Yard Duct Runs.Sheet 1 of 1 ML17312A2031996-08-31031 August 1996 Hutchinson Island Plant Unit 1 Schematic Diagram Intake Cooling Water Pump 1A.Sheet 832 ML17312A2041996-08-21021 August 1996 Hutchinson Island Plant Unit 1 Schematic Diagram Intake Cooling Water Pump 1B.Sheet 833 ML17317A5681996-08-20020 August 1996 Flow Diagram Turbine Lube Oil System.Sheet 3 ML17312A0921996-08-11011 August 1996 Schematic Diagram Component Cooling Water Pump 1A.Sheet 201 ML17312A2411996-08-11011 August 1996 ST Lucie Plant Extension Unit 1 Control Wiring Diagram Index.Sheet 8 ML17317A5601996-08-0707 August 1996 Flow Diagram Instrument Air System.Sheet 3 ML17317A5741996-08-0606 August 1996 Containment Spray Piping Plan.Sheet 1 ML17317A5751996-08-0606 August 1996 Containment Spray Piping Sections ML17317A0321996-08-0606 August 1996 Reactor Auxiliary Bldg Instrument Arrangement.Sheet 1 ML17317A3841996-08-0606 August 1996 Reactor Auxiliary Bldg Instrument Arrangement.Sheet 3 of 4 ML17312A2401996-08-0101 August 1996 ST Lucie Plant Extension Unit 1 Control Wiring Diagram Index.Sheet 7 ML17312A2321996-07-24024 July 1996 Hutchinson Island Plant Unit 1 Schematic Diagram Diesel Generator 1B Start Ckts.Sheet 967 ML17312A1701996-07-24024 July 1996 Flow Diagram Miscellaneous Systems.Sheet 2 ML17312A2511996-07-24024 July 1996 Hutchinson Island Plant Unit 1 Schematic Diagram Diesel Generatoria Start Ckts.Sheet 957 ML17312A1811996-07-23023 July 1996 Hutchinson Island Plant Unit 1 Schematic Diagram Safety Injection Flow Control Valves.Sheet 257 ML17312A1961996-07-23023 July 1996 Flow Diagram Miscellaneous Sampling Systems.Sheet 1 ML17312A2231996-07-23023 July 1996 Hutchinson Island Plant Unit 1 Schematic Diagram Diesel Generator 1A Lock Out Relay.Sheet 956 ML17317A5591996-07-23023 July 1996 Flow Diagram Instrument Air System.Sheet 2 ML17312A2011996-07-23023 July 1996 Flow Diagram Secondary Side Wet Layup System Feedwater Heaters Tube Side & Steam Generators.Sheet 1 ML17317A3721996-07-23023 July 1996 480V Miscellaneous 125V DC & Vital AC One Line.Sheet 2 ML17312A2311996-07-23023 July 1996 Hutchinson Island Plnat Unit 1 Schematic Diagram Diesel Generator 1B Lock Out Relay.Sheet 966 ML17312A1021996-07-15015 July 1996 Flow Diagram Safety Injection System (Sheet 2).Sheet 131 ML17312A1231996-07-0909 July 1996 Flow Diagram Heater Drain & Vent Systems ML17312A1451996-07-0909 July 1996 HVAC-CONTROL Diagrams.Sheet 1 ML17317A3711996-07-0303 July 1996 480V Miscellaneous 125V D-C & Vital A-CONE Line.Sheet 1 ML17312A0971996-06-28028 June 1996 Flow Diagram Reactor Coolant System.Sheet 110 ML17312A2061996-06-27027 June 1996 Hutchinson Island Plant Unit 1 Schematic Diagram Intake Cooling Water Pump 1C.Sheet 834 ML17312A1121996-06-20020 June 1996 Flow Diagram Main Steam.Sheet 1 ML17312A1201996-06-17017 June 1996 Flow Diagram Feedwater L& Condensate Systems.Sheet 2 ML17312A1151996-06-17017 June 1996 Flow Diagram Extraction Steam.Sheet 3 ML17312A1711996-06-17017 June 1996 Flow Diagram Containment Spray & Refuiling Water Systems ML17312A1011996-06-0505 June 1996 Flow Diagram Safety Injection System (Sheet 1).Sheet 130 1997-11-28
[Table view] |
Text
SG tA 5 DM MSIS MSIS MS IS MS IS IDOL 9L'lt CHANNEL A CHANNEL B NOTES rex-23-5/23-7 CHANNEL A CHANNEL B CISi RA D O'I/'E'D ACTUATION ACTUATION For typical annunciator ACTUATION BLOC IKD ACTUATION
-BLOCKED window description see Q-6 Q-7 Q-10 sheet 802 31$
NO 4&I NO MSIS-A cr- 330 NO MSIS-A 330 NO MS IS- B 331 NO MS IS- B 331 Z
Engraving by field CNTMT SG 1A MSIS SG 1B MS IS HI RADIATION LOW PRESS CHANNEL A LOW PRESS CHANNEL B Q3- 3-1/313, 3-2/313,94-1/3IB CIS- MEAS MSIS MEAS: ACTUATION MSIS MEAS ACTUATION :3=1/431, 3-2/4E I, .34-1/4E I NO CHANNEL TRIP CIS-MA, -NB, -MC, -MD 295 NO CHANNEL TRIP MS IS-MA, -MB, -MC, -MD 17 295 NO BLOCI< PERMISS MSIS-A
-18 330 NO CHANNEL TRIP MSIS-MA,-MB,-MC,-MD 295
-19 NO BLOCIC PERMISS MSIS-B Q-20 331
Mul tip le alarm input wx.th ref lash capa bility CNTNT AFAS BISTABLE: AFAS STM GEN AFAS STM GEN AUX STN LINE ISOL HI RADIATION PRE- TRIP FAULTED CHANNEL LOW LEVEL NV-08-12 CLOSE/
CIS PRE TRIP TRIP CHANNEL TRIP CS OPEN/
Q-26 Q-27 Q- 28 Q- 29 MTR OVLD Q-30 NO AQ-26-1/457 457 NO AFAS (MA,MB,MC,MD) - 72 NO AFAS (MA,I EB, MC, MD) NO AFAS (NA,MB,MC,MD) -72 NO 74/753, 33/LSC, 4Z C 753 RADIATION AFAS FWP 1A/1B FWP 1A/1B DISCH CONTROL ROOM MONITORING DISCH VALVES TO SG 1A/1B OAI/RAB TROUBLE/TEST POWER MV 1/- 2 MV-09-7/-8 TEMP FAILURE MTR OVRLD MTR OVRLD HIGH
-37 Q-38 Q-40 OG RATEMETERS 36'57 NO H 1 THRU CH 27 NO AFAS (MA,MB,NC, MD) 72 NO 74 621 NO 74 NO QQAD-I/75I, AQ-40-2/15k 751 INSTR AIR ISOL MAIN STN ISOL MAIN STM ISOL I RAB/DECON RM I MV 1 HCV 1A HCV 1B Ii MOTOR LOW AIR PRESS/ LOW AIR PRESS/
HIGH OVERLOAD DC FAILURE DC FAILURE RKORM Q-48 Q-50 KUCLEPR NO 74 317 ¹ 74 PS-08-12A 312 NO NO 74 PS-08-12B 315 NO TS-08=5, TS 6 751 NENT'WNTNOE CENTER ji PRI WTR MAIN STN ISOL MAIN STN ISOL MAIN STN ISOL MAIN STM ISOL ISOLATION BYPASS MV-08-1A BYPASS MV-08-1B Rl2=. PCM 185- 93 1 HCV-08-1A HCV-08-1B :Rli.- PC 8 Z4S-. I88....
MOTOR MV 1 MOTOR FAIL TO CLOSE RtO- PCM I40-I84 FAIL TO CLOSE Re-- gaDRP'A PgM ICZ,-.BO..........
MTR OVRLD Q-56 OVERLOAD Q-58 Q-59 OVERLOAD N Q-57 Q 60 gQ NO 74 849 No 94,33x 312 NO 74 311 NO 94, 33X 315 74 314 R .I:=B I-..13 0=. k F..
NO RE .:=AS. BLlILT I5 R,e-/v c EBASCO SERV1CES INCORPORATEO FLORIDA POV/ER 8 LIGHT CO-NEW YORK I'4 v-1848 HUTCHINSON ISLAND PLANT-UNIT NO I 8770-8-327 L-'8 SIN DIVM 23EN.' .:-'CONTROL -SIRING DIAGRAM
-14K NV. sHEE'T 365 I 2. /0 0' schLE CH ENGINEERED SAFEGUARDS EV DATE BY APPROVED REV DATE BY APPROVED g>AyE 7lt t- 2 3, I 172 lP L I/T,P 'NNUNCIATOR-Q SH 2 RTGB-106-