ML17311B154

From kanterella
Jump to navigation Jump to search
Forwards LER 95-002-01,providing Addl Info on Cause, Corrective Actions & Safety Significance of Temp Dependent Shutdown Margin Used in Mode 3 Steam Line Break Analysis Reported in Original Submittal
Date released: 07/31/2018 Download: ML17311B154


LER 95-002-01:on 950303,identified That Slb Analyses Failed to Consider as Initial Condition One Percent SDM for All Rods in (ARI) Due to Lack of Coordination & Unclear Div of Responsibilities.Ari Core Data Book SDM Curves Modified
ML17311B155
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 08/25/1995
From: Grabo B
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
References
Download: ML17311B155 (14)
Forwards LER 95-002-01,providing Addl Info on Cause, Corrective Actions & Safety Significance of Temp Dependent Shutdown Margin Used in Mode 3 Steam Line Break Analysis Reported in Original Submittal
ML17311B153
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 08/25/1995
From: James M. Levine
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML17311B153 (4)