ML17305A864

From kanterella
Jump to navigation Jump to search
Errata to Monthly Operating Rept for Apr 1990 for Palo Verde Nuclear Generating Station,Unit 2
ML17305A864
Person / Time
Site: Palo Verde 
Issue date: 04/30/1990
From: Porter K
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
Shared Package
ML17305A861 List:
References
NUDOCS 9006050342
Download: ML17305A864 (4)


Text

0 NRC MONTHLY OPERATING REPORT

~~

AMENDED~*

DOCKET NO.

50-529 UNIT NAME PVNGS-2 DATE COMPLETED BY K F Porter OPERATING STATUS 1.

2.

3.

4, 5.

6.

7.

8.

9.

10.

Unit Name:

alo Verde Nuclear Generatin Station Unit 2 Reporting Period:

A ril 1990 Licensed Thermal Power (MWt):

3800 Nameplate Rating (Gross MWe):

1403 Design Electrical Rating (Net MWe):

~12 0 Maximum Dependable Capacity (Gross MWe): 1303 Maximum Dependable Capacity (Net MWe):

~122 If Changes Occur In Capacity Ratings (Item Numbers 3 Through 7)

Since Last Report, Give Reasons:

A Power Level to Which Restricted, If Any (Net MWe):

None Reasons For Restrictions, If Any:

N A 11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23

'4.

Hours in Reporting Period Number of Hours Reactor Was Critical Reactor Reserve Shutdown Hours Hours Generator On-Line Unit Reserve Shutdown Hours Gross Thermal Energy Generated (MWH)

Gross Electrical Energy Generated (MWH)

Net Electrical Energy Generated (MWH)

Unit Service Factor Unit Availability Factor Unit Capacity Factor (Using MDC Net)

Unit Capacity Factor (Using DER Net)

Unit Forced Outage Rate Shutdowns Scheduled Over Next 6

N A This Month 20 Yr.-to-Date 2 880 Cumulative 31 680 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Months (Type, 1 295 0

0 0 1 295 0

0 0 20 546 1

0 0 20 042 2

0 0 480 00 1 712 500 3 499 053 25 682 370 1 614 008 23 996 820 45 0

45 0

63 3

63 3

45 9

62 0 59 6a 9

9 Date and Duration of Each):

25. If Shutdown At End of Report Period, Estimated Date of Start-up:

June 12 1990 INITIALCRITICALITY INITIALELECTRICITY COMMERCIAL OPERATION Forecast

~03 86 06 86 11 86 Achieved 04/418 86 05 20 86 09 19 86 1 DR S OOOO DQCK O~OOOS1

~Dc 6

't fl I

ll

,'ll

ATTACHMENT The NET ELECTRICAL ENERGY GENERATED (MWH) for Unit 2 during February 1990 was reported as 693,616 megawatt-hours.

It should have been reported as 683,616 megawatt-hours, a difference of 10,000 megawatt hours (1.5 percent).

The February 1990

Monthly, Year-to-Date, and Cumulative NET ELECTRICAL ENERGY GENERATED and CAPACITY FACTORS have been adjusted to reflect this change.
Likewise, the March 1990 and April 1990 Year-to-Date and Cumulative NET ELECTRICAL ENERGY GENERATED and CAPACITY FACTORS have been adjusted accordingly.

0

'0 i