ML17304A620

From kanterella
Jump to navigation Jump to search
Forwards Palo Verde Nuclear Generating Station Unit 2, Inservice Insp Rept,First Refueling, Per Tech Specs 4.0.5 & 6.9.2
ML17304A620
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 09/26/1988
From: Haynes J
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML17304A621 List:
References
192-00414-JGH, 192-414-JGH, NUDOCS 8810070052
Download: ML17304A620 (3)


Text

p gCgP~WTED ~~BUTION REGULATORY INFORMATION DEMON~TION DISTRIBUTIOh'YSTEM (RIDS)

SYSTEM ACCESSION 'NBR:8810070052 DOC.DATE: 88/09/26 NOTARIZED: NO DOCKET g FACIAL'.STN-50-529 Palo Verde Nuclear Station, Unit 2, Arizona Public 05000529 AUTH. NAME AUTHOR AFFILIATION HAYNES,J.G. Arizona Nuclear Power Project (formerly Arizona Public Serv RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards "Palo Verde Nuclear Generating Station Unit 2, Inservice Insp Rept, First Refueling."

DISTRIBUTION CODE: A047D TITLE: OR COPIES RECEIVED:LTR ( ENCL +

Submittal: Inservice Inspection/Testing/Relief from SIZE: / 7 ASME Code D

NOTES:Standardized plant. 05000529 8

RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD5 LA 1 -

0 PD5 PD 5 -

5 CHAN i T 1 1 DAVIS,M 1 1 INTERNAL: ACRS 6 6 AEOD/DSP/TPAB 1 1 ARM/DAF/LFMB 1 0 NRR/DEST/MEB 9H 1 1 NRR/DEST/MTB 9H 1 1 -ABSTRACT 1 1 OGC/HDS1 1 0 REG ML 01 1 1 RES/DSIR/EIB 1 1 EXTERNAL: EGGG ROCKHOLDiH 1 1 LPDR 1 1 NL 007 HEMMING 1 1 NRC PDR 1 1 NSIC 1 1 NOTES: 1 1 8

I

/

h TOTAL NUMBER OF COPIES REQUIRED: LTTR 28 ENCL 25

Arizona Nuclear Power Project P.O. BOX 52034 ~ PHOENIX, ARIZONA85072-2034 192-00414-JGH/TDS/JJN September 26, 1988 NRC Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555

Dear Sirs:

Subject:

Palo Verde'uclear Generating Station (PVNGS)

Unit 2 Docket No. STN 50-529 (License No. NPF-41)

Special Report Unit 2 Refueling Inservice Inspection File: 88-020-404 Attached please find a Special Report prepared and submitted pursuant to Technical Specifications 4.0.5 and 6.9.2. This report discusses the Inservice Inspection performed during the unit refueling. By copy of this letter we are also forwarding a copy of this report to the Regional Administrator of the Region V office.

If you have any questions, please contact T. D. Shriver, Compliance Hanager at (602) 393-2521.

Very truly yours, J. G. Haynes Vice President Nuclear Production JGH/TDS/JJN/kj Attachment cc: D. B. Karner (all w/a)

E. E. Van Brunt, Jr.

J. B. Hartin T. J. Polich H. J. Davis A. C. Gehr INPO Records Center 88i00700S PDR 8809gg PoV 7 gDOC>

CK 05000~F9 I PhlU )

's F

~

I