CONTAINMENT SYSTEMS ELECTRIC HYDROGEN RECOMBINERS LIMITING CONDITION FOR OPERATION 3'.4.2 Two portable'ndependent containment hydrogen recombiner systems shared among the three units shall be OPERABLE.
APPLICABILITY:
MODES 1 and 2.
ACTION:
With one hydrogen recombiner system inoperable, restore the inoperable system to OPERABLE status within 30 days or meet the requirements of Specification 3.6.4.3, or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
SURVEILLANCE RE UIREMENTS 4.6.4.2 Each hydrogen recombiner system shall be demonstrated OPERABLE:
a.
b.
C.
At least once per 6 months by:
1.
Verifying through a visual examination that there is no evi-dence of abnormal conditions within the recombiner enclosure and control console.
feconibiner ~
indium
~
2.
Operating thehair blast heat exchanger fan motor and enclosed blower motor continuously for at least 30 m'autosm}-
o cri-appfofu~
q moo i= f.~ssc4m c.
- ~t it fs-,
At least once per year 5yg
~ perfo min a
CHANNEL CALIBRATION of recombiner instrumentatio iss Lmc at ~+
W ~
~~~bin~ g.+ t~o I=')~
2.
Performing a "Low-eve est-eater Power 0 f" an "Low"Leve ~ tcsf-Test-Heater Power On" test and verifying that the recombiner temperature increases to and is maintained at 600 + 25'F for at least one hour.
With power off and a simulated input signal of 1280 F., verify the OPERABILITY of all control circuits.
Whe this test is conducted, the air blast heat exchanger fan motor and enclosed blower motor shall be operated continuously for at least 30 minutes.
At least once per 5 years by performing a Recombiner System "High-Level Test" and verifying that the recombiner temperature increases to and is maintained at 1200 + 50'F for. at least one hour f'g.o ~@I=- Lihi~g 8702020iOi 870i23
'PDR kDQCK 05000528 p
PDR 3/4 6-37
CONTAINMENT SYSTEMS ELECTRIC HYDROGEN RECOMBINERS LIMITING CONDITION FOR OPERATION 3.6.4.2 Two portable'independent containment hydrogen recombiner systems shared among the three units shall bs OPERABLE.
APPLICABILITY:
MODES 1 and 2.
ACTION:
With one hydrogen recombiner system inoperable, restore the inoperable system to OPERABLE status within 30 days or meet the requirements of Specification 3.6.4. 3, or.be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
SURVEILLANCE RE UIREMENTS 4.6.4.2 Each hydrogen recombiner system shall be demonstrated OPERABLE:
At least once per 6 months by:
b.
l.
Verifying through a visual examination that there is no evi-dence of abnormal conditions within the recombiner enclosure and control console.
recon>bing- ~ tvtd 2.
Operating the/air blast heat exchanger fan motor and enclosed blower motor continuously for at le st 30 m'nutesQ+
a.
srf +pprofu~
9 '400 Pf'r 4m)
At least once per year by+
~ Per fo min a,CHANNEL CALIBRATION of recombibner instrumentatio 4e imc af ~+ df ~a <~~~<<W ct.+
lQGo<
F)~
2.
Performing a "Low-eve est-eater Power 0 f" an "Low-Leve ~(~
Test-Heater Power On" test and verifying that the recombiner temperature increases to and is maintained at 600 + 25'F for at least one hour.
With power off and a simulated input signal of 1280'F, verify the OPERABILITY of all control circuits.
Whe this test is conducted, the air blast heat exchanger fan motor and enclosed blower motor shall be operated continuously for at least 30 minutes.
C.
At least once per 5 years by performing a Recombiner System "High-Level Test" and verifying that the recombiner temperature increases to and is maintained at 1200 + 50 F for at least one hour 3/4 6-37