SPECIAL TEST EXCEPTIONS 3/4.10.2 MODERATOR TEMPERATURE COEFFICIENT, GROUP HEIGHT INSERTION, AHO POWER-O.ES I RIBUTIOH LIMITS LIMITING CONDITION FOR OPERATION S. I.3,>

3.10.2 T e moderator temperature coefficient, group height, insertion, and power di tribvtion limits of Specifications 3.1.1.3, 3.1.3.1, 3.1.3.5,

3. 1.3.6, 3.2.2, 3.2.3, 3.2.7, and the Minimum Channels OPERABLE requirement of I.C. 1 (CEA Calculators) of Table 3.3-1 may be suspended during the performance of PHYSICS TESTS provided:

a e b.

The THERMAL POWER is restricted to the'test power plateau which shall not exceed 85K of RATED THERMAL POMER, and The limits of pecification 3. 2. 1 are maintained and determined as specified in Specification 4.10.2.2 below.

(

V

.ptq APPLICABILITY:

MODES 1 and 2.

ACTION:

3.(.3,7 lfith any of the limits of Specification 3.2.1 being exceeded while~

I requirements of;Specifications

3. 1. 1.3,
3. 1.3.1", 3. 1.3.5,
3. 1.3.6, 3.2.2, 3.2.3, 3.2.7, and the Minimum Channels OPERABLE requirement of I.C.1 (CEA Calcvlators) of Table 3.3-1 are svspended, either:

a.

Reduce THERMAL POMER sufficiently to satisfy the requirements of Specification 3.2.1, or b.

Be in HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

SURVEILLANCE RE UIREMEHTS

4. 10.2.1 The TH RMAL POWER shall be determined at least once per hour during PHYSICS TESTS in hich the requirements of Specifications
3. 1. 1.3,
3. 1.3. 1, or the u

ann OP A

eqvire-3.1.3.5, 3.1.3.6, 3.2.2, 3.2.3, 3.2.7, M>nin m Ch els ER BLE r ment of I.C. 1 (CEA Calculators) of Table 3,3-1 are suspended and shall be verified to be within the'est power plateau.

4. 10,2.2 The linear heat rate shall be determined to be within the limits of Specification 3.2. 1 by monitoring it continuously with the Incom-Detector Monitoring System pursuant to the requirements of Soecifications
4. 2. l. 3 and 3.3.3.2 during PHYSICS TESTS above 20~ of RATED THERMAL POMER in which the requirements of Specifications
3. 1. 1.3,
3. 1.3. 1,
3. 1.3.5,
3. 1.3.6, 3.2.2, 3.2.3, 3.2.7, or the Minimvm Channels OPERABLE requirement of I.C.

(CEA Calculators) of Table 3.3-1 are suspended.

8712280329 871211 J

PDR ADOCK 05000528 P

PDR PALO VERDE " UNIT 1 3/4 10-2

0 Cg fj

. SPECIAL TEST EXCEPTIONS 3/4.10.4 CEA POSITION, REGULATING CEA INSERTION LIMITS AND REACTOR COOLANT COLD LEG TEMPERATURE LIMITING CONDITION FOR OPERATION

)0< 37 3.10.4 The requirements of Specifications 3.1.3.1, 3.1.3.6 and 3.2.6 may be suspended during the performance of PHYSICS TESTS to determine the isothermal temperature coefficient, moderator temperature coefficient, and power coefficient provided the limits of Specification

3. 2. 1 are maintained and determined as specified in Specification
4. 10.4.2 below.

APPLICABILITY:

MODES 1

and 2.

',5.l. K7 Wi.th any of the limits of Sp'ecification 3.2.1 bei d QhiTe the requirements of Specifications 3.1.3.1, 3.1.3.6 nd 3.2.6 are suspended, either:

a.

Reduce THERMAL POWER sufficiently 'to satisfy the requirements of Specification 3.2.1, or b.

Be in HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

SURVEILLANCE RE UIREM'ENTS

4. 10.4. 1 The THERMAL POWER shall be determined at least once per hour during PHYSICS TESTS in which the requirements of Specifications
3. l. 3. 1, 3. l. 3. 6, 3.( 3.g and/or 3.2.6 are suspended and shall, be verified to be within the test power
4. 10.4.2 The linear heat rate shall be determined to be within the limits of Specification
3. 2. 1 'by monitoring it continuously with the Incore Detector Monitoring System pursuant to the requirements of Specification 3.3.3.2 during PHYSICS TESTS above 20% of RATED THERMAL POWER in which the requirements of Specifications
3. 1.3. 1, 3. 1.3.6 and/or 3.2.6 are suspended.

L

, 3.l. 3,q