Responds to Util 860801 Request for Temporary Relief from Entering Action Statements Due to Processing of Change to Tech Spec 3/4.7.7 Re Operability of Control Room Essential Filtration Sys.Relief Granted Until 860805
ML17300A315
Person / Time
Site: Palo Verde  
Issue date: 08/06/1986
From: Knighton G
Office of Nuclear Reactor Regulation
To: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
References
NUDOCS 8608080283
Download: ML17300A315 (4)


Text

August 6, 1986

,Docket Nos.:

50-528 and 50-529 Mr. E.

E.

Van Brunt, Jr.

Executive Vice President Arizona Nuclear Power Project Post Office Box 52034 Phoenix, Arizona 85072-2034

Dear Mr. Van Brunt:

DISTRIBUTION oc et i

e PD7 Reading NRC/PDR LPDR EALicitra JLee FMiraglia DKirsch JPartlow BGrimes EJordan

Attorney, OGC ACRS (10)

Subject:

Relief Request from Technical Specification 3/4.7.7 for Palo Verde Units 1 and 2

Your letter ANPP-37657, dated August 1, 1986 requested temporary relief from entering action statements due to the requirements of the subject Technical Specification for Palo Verde Units 1 and 2, regarding operability of the control room essential filtration system, to allow Palo Verde, Units 1 and 2, to continue operation while an emergency Technical Specification change is processed.

As stated in your letter, the need for relief occurred when it was determined that the charcoal filters installed in this system for Palo Verde, Units 1 and 2, did not meet the radioiodine removal efficiency of ANSI Standard N509-1976, and, therefore, are not in conformance with the surveillance testing require-ments of Specification 3/4.7.7.

The justification provided for the relief request is that continued operation of the Palo Verde units will not result

.in an unsafe condition since the charcoal filters do meet the testing requirements of the 1980 version of ANSI Standard N509 and this standard has been accepted'by the staff as an alternative in Section 6.5. 1 of the Standard Review Plan.'

This letter confirms the decision given to your staff by telephone on August 1, 1986, at approximately 3:45 pm HST, that the requested relief was granted unti l 5:00 pm MST August 5, 1986.

Sincerely,

'; 8608080283 860806 PDR ADpcg pgpppgg8 PDR

)r cc:

See next page

/s/

George W. Knighton, Director PWR Project Directorate No.

7 Division of PWR Licensing-B PD7$/

ADIR:RV EAL>ci ra/yt DKirsch 8/$ /86 J~ 8/1/86 telephone concurrence FM)r a

s/g /s6 PD7 G

ghton 8/

/86

3 FI I

33(

Ve f

I I

I ~

IF J,

3 II I Il I I 3 F

feed S e

3 F 3I FI

'F

Mr. E. E.

Van Brunt, Jr.

Arizona Nuclear Power Project Palo Verde CC:

Arthur C. Gehr, Esq.

Snell E Wilmer 3100 Valley Center Phoenix, Arizona 85073 Mr. James M. Flenner, Chief Counsel Arizona Corporation Commission 1200 West Washington Phoenix, Arizona 85007 Charles R. Kocher, Esq. Assistant Council James'A.

Boeletto, Esq.

Southern California Edison Company P. 0.

Box 800

Rosemead, California 91770 Mr. Mark Ginsberg Energy Director Office of Economic Planning and Development 1700 West Washington - 5th Floor Phoenix, Arizona 85007 Kenneth Berlin, Esq.

Winston 5 Strawn Suite 500 2550 M Street, NW Washington, DC 20037 Ms. Lynne Bernabei Government Accountability Project of the Institute for Policy Studies 1901 Que Street, NW Washington, DC 20009 Ms. Jill Morrison 522 E. Colgate Tempi, Arizona 85238 Mr. Charles B. Brinkman, Manager Washington Nuclear Operations Combustion Engineering, Inc.

7910 Woodmont Avenue Suite 1310

Bethesda, Maryland 20814 Mr. Wayne Shirley Assistant Attorney General Bataan Memorial Building Santa Fe, New Mexico 87503 Mr. Ron Rayner P. 0.

Box 1509

Goodyear, AZ 85338 Hr. Roy Zimmerman U.S. Nuclear Regulatory Commission P. 0.

Box 239 Arlington, Arizona 85322 Ms. Patricia Lee Hourihan 6413 S. 26th Street Phoenix, Arizona 85040 Regional Administrator, Region V

U. S. Nuclear Regulatory Comnission 1450 Maria Lane Suite 210 Walnut Creek, California 94596