ML17299A902

From kanterella
Jump to navigation Jump to search
Auxiliary Feedwater Pump 48 H Endurance Test Results, Per Sser (NUREG-0857)
ML17299A902
Person / Time
Site: Palo Verde 
Issue date: 12/24/1985
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Knighton G
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0857, RTR-NUREG-857 ANPP-34329-EEVB, NUDOCS 8512310150
Download: ML17299A902 (35)


Text

'r RECULAOIY INFORNATION DISTRIDUTI(SYSTEN (RIDE')

ACCESSION NBR: 8512310150 DOC. DATE: 85/12/24 NOTARIZED:

NO DOCKET 0 FACIL:STN-50-529 Palo Verde Nuclear Stationi Unit 2i Arizona Publi 05000529 AUTH. NANE AUTHOR AFFILIATION VAN BRUNT', E.

Arizona Nuclear Power ProJect (Formerly Arizona Public Serv RECIP. NANE RECIPIENT AFFILIATION KNIQHTON Q. M.

PMR Prospect Directorate 7

SUBJECT:

"Auxiliary Feedeater Pump 48 H Endurance Test Resultsi" per SSER (NUREQ-0857). N/851224 ltr.

DISTRIBUTION CODE:

AOOID COPIES RECEIVED: LTR g ENCL +

SIZE:

TITLE:

OR Submittal:

Qeneral Distribution NOTES: Standardized plant.

05000529 RECIPIENT ID CODE/NANE PNR-B PD7 PD 01 INTERNAL: ACRS 09 ELD/HDS3 NRR PNR-A EB NRR/DHFT/TSCB NRR RBW B

E~LE 04 COP IES LTTR ENCL 5

5 6

1 0

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME LICITR*iE ADM/LFNB NRR BMR EB NRR PNR-B EB NRR/DSRO DIR NRR/GRAS RQN5 COPIES LTTR ENCL 1

1 1

0 1

1 1

1 1

1 0

1 1

EXTERNAL: 24X LPDR NSIC 03 05 1

1 1

EQSQ BRUSKEi 8 NRC PDR 02-,

1 1

1 1

TOTAL NUNBER OF COPIES REQUIRED:

LTTR 28 ENCL 25

~

II II I

- wi,l Jl Xf' Q

I 4

I 'lf I

'Il I

0 P

4 jww 45 4

VI 44

~ 4

, 43k ff V,I; I

4 )'w I WI I

J (I'

Jfl fw Jl RP I 4 "I

wg

, llx,(

ff I

wx 44 If 4 tf X",ii 4 I

E,I

'VV

VI 4

I 4

'll I ~ VX R

w. 4,>-C, I',

~

4

Arizona Nuclear Power Project P.O. BOX 52034

~

PHOENIX. ARIZONAB5072-2034 December 24, 1985 ANPP-34329-EEVB/PGN-98.07 Director of Nuclear Reactor Regulation Attention:

Mr. George W. Knighton, Deputy Director PWR Project Directorate II7 Division of Pressurized Water Reactor Licensing B U. S. Nuclear Regulatory Commission Washington, D.C.

20555

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Unit 2 Docket No.

STN 50-529 (License NPF-46)

Auxiliary Feedwater Pump 48 Hour E'ndurance Test File:

85-056-026

Reference:

Safety Evaluation Report'elated to the operation of Palo Verde Nuclear Generating

Station, Units 1, 2

and 3

(NUREG<857) dated

November, 1981

Dear Mr. Knighton:

As required by Section 22.2 (II.E.l.l) of the above reference, please find attached the results of the auxiliary feedwater system (AVOWS) pump 48-hour endurance tests.

If you have any questions or require additional information, please contact Mr. W. F. Quinn of my staff.

Very truly yours, CUW E. E.

Van Brunt, Jr.

Executive Vice President Project Director EEVB/WFQ/PGN/dim Attachment cc:

E. A. Licitra M. C. Ley R. P.

Zimmerman A. C. Gehr

.. lad:

g D, CRUTCNPIELD (Ltr only)

EB (N JO!OISTON)

RSB (TIIONAS)

I EICSB (PARR).

~

FOB (II REOAN)

0, it 0

~

0 0

Attachment to ANPP-34329 ATTACHMENT Auxiliary Feedwater Pump 48 Hour Endurance Test Results 8512310150 851224 I

PDR ADOCK 05000529 F

PDR

Page 2

1) 2M-AFN-POl - Non-essential AFW pump 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> endurance testing data:

a)

Date of testing:

July 2, 1985 through July 4, 1985 b)

Bearing Temperatures The limits for each bearing temperature, along with the maximum obtained temperature are listed below:

AFN-TE-79 AFN-TE-81 AFN-TE-89 AFN-TE-90 AFN-TE-91 (Limit 190'F max)

(Limi.t 190'F max)

(Limit 200'F max)

(Limit 200'F max)

(Limit 200'F max)

Max.

Max.

Max.

Max.

Max.

161'F 153'F 161 F

152'F 163'F c)

Flow Data:

Data was collected with a clamp on flowmeter on the recirculation line to the CST.

The MITE used was a

Controlotron Model 865580 and flow data recorded was about 280 gpm during the test.

d)

Vibration Data:

Data was collected using a

hand held vibration meter and probe.

The M&TE used was an IRD Model 8810.

The maximum vibration limits are 5

mils and the actual vibrations recorded during the test are listed below:

Inboard bearing:

.4.6 mils Outboard bearing:

.9 1.2 mils The 91PE-2AF01 48-hour endurance run demonstrated that 2M-AFN-POl remained within design limits with respect to bearing tempera-tures and vibration.

The following plots made for the bearing temperatures versus time demonstrated that the design limits were not exceeded.

2M-AFN-PO1 AUXILIARYFEEDWATER PUMP

AFN-TE-79 FREE END MOTOR BEARING 170 160 150 140 s

130 00 a

120 I

5 110 IC 100 I

80 70 60 0

2 4

6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TINE - Hours 48 HOUR RUN I

0 I

I HOUR RUN AFTER COOLDOWN

2M-AFN-P01 AUXILIARY FEEONATER PUMP AFN-TE-81 COUPLING END MOTOR BEARING 170 160 150 140 u

130 a

120 5

110 100 90 80 70 60 0

2 4

6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TINE - Hours 48 HOUR RUN I

I 0

I 1

HOUR RUN AFTER COOLDOIIN

C

2M-AFN-P01 AUXILIARY FEEDMATER PUMP AFN-TE-89 PUMP THRUST SEARING 170 160 150 140 u

130 0

o 120 I

EIJ 5

110 100 80 80 70 60 0

2 4

6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TINE - Houcs 48 HOUR RUN 0

1 I HOUR RUN AFTER COOLOOW

l'

2M-AFN-POl AUXILIARY FEEOWATER PUMP AFN-TE-90 PUMP COUPLING ENO JOURNAL BEARING 170 160 150 140 130 a0 o

120 I

5 110 100 I

90 80 70 60 0

2 4

6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TINE Hour o 48 HOUR RUN M

0 1

1 HOUR RUN AFTER COOLOOMN

2M-AFN-PO1 AUXILIARYFEEOWATER PUMP AFN-TE-91 PUMP FREE ENO JOURNAL BEARING

'l 170 160 150 140 g

130 120 I

5 110 100 I

90 80 70 60 0

2 4

6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TINE Hours 48 HOUR RUN 0

1 1

HOUR RUN AFTER COOLDOMN

Page 8

2) 2M-AFB-P01 Essential APW pump 48-hour endurance testing data:

a)

Date of Testing:

June 13, 1985 through June 15, 1985.

b)

Bearing Temperatures - The limits for each bearing temperature, along with the maximum obtained temperature are listed below:

AFN-TE-80.

AFN-TE-82 AFN-TE-86 AFN-TE-87 AFN-TE-88 (Limit 190'F max)

(Limit 190'F max)

(Limit 200'F max)

(Limit 200'F max)

(Limit 200'F max)

Max. 151'F
Max. 149'F
Max. 162'F
Max. 161'F
Max. 148'F c)

Flow Data:

Data was collected using a clamp on flowmeter on the recirculation line to the CST.

The METE used was a

Controlotron Model fI65580 and flow data recorded was about 235 gpm during the test.

d)

Vibration Data:

Data was collected using a

hand held vibration meter and probe.

The ATE used was and IRD Model 8810.

The maximum vibration limits are 5

mils and the actual vibrations recorded during the test are listed below.

Inboard Bearing:

.8 1.0 mils Outboard Bearing:

.9 1.2 mils e)

Pump room temperature and humidity data:

Data was collected using a

psychrometer to measure wet and dry bulb temperatures.

From this data relative humidity was also calculated.

Temperature Range:

68'F - 73'F Relative Humidity Range:

52% 82%

The 48-hour endurance run demonstrated that 2M-AFB-P01 remained within design limits with respect to bearing temperatures and vibrations.

The test data also showe'd that the pump room ambient conditions (temperature, humidity) did not exceed environmental qualification limits for safety related equipment in the

room, The following plots made for the bearing temperatures versus time demonstrated that the design limits. were not exceeded.

Plots were also made fo'r the pump room temperature and humidity data versus time.

2M-AFB-PO1 AUXILIARY FEEOMATER PUMP AFN-TE-BO FREE ENO MOTOR BEARING 160

+FOR THE FIRST 2.5

HOURS, A PROBLEN EXISTED WITH THE INPUT TO THE PLANT COHPUTER.
OATh, AS SHOWN.

IS NOT REPRESENTATIVE OF INITIAL STARTING TENPERATURES.

SUPPLENENTARY DATA IS AVAILABLEIN APPENDIX E OF 91PE-2AFOI ~

ISD 140 a

130 aa a

120 I

5 110 100 90 80 70 0

2 4

6 9

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 49 TIME - Hours 49 HOUR RUN 0

I HOUR RUN AFTER COOl DOWN

O.

f

2M-AFB-POl AUXILIARYFEED>/ATER PUMP AFN-TE-82 COUPLING END MOTOR BEARING Oo (D

170 160 150 140 130 0

Ql c) 120 I

5 110 100 I

80 70 60 0

2 4

6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TIHE - Hours 48 HOUR RUN 0

1 1

HOUR RUN AFTER COOLOOVN

2M-AFB-P01 AUXILIARYFEEDWATER PUMP AFN-TE-86 PUMP FREE END JOURNAL BEARING gqs I

e e

170 160 150 140 g

130 ee 120 I

5 110 100 e

90 80 70 60 2

4 6

8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 T1HE - Hours 48 HOUR RUN 0

1 1

HOUR RUN AFTER COOLOOWN

2M-AFB-PO1 AUXILIARYFEEDWATER PUMP AFN-TE-87 PUMP COUPLING END JOURNAL BEARING 170 160 150 140 g

130 0

a 120 I

5

110, 100 I

90 80 70 60 0

2 4

6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TINE Hours 48 HOUR RUN 0

1 I HOUR RUN AFTER COOLDOWN

2M-AFB-P01 AUXILIARY FEEDWATER PUMP AFN-TE-88 PUMP THRUST BEARING 170 160 150 140 y

130 00 o

120 I

5 110 I

100 90 80 70 60 2

4 6

8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TJME - Hours 48 HOUR RUN M

0 1

HOUR RUN AFTER COOLOOWN

2M-AFB-PO1 AUXILIARY FEEDWATER PUMP ROOM ENVIRONMENTAL DATA 90 BO I

I H

70 w

60

)

I-50 40 0

2 4

6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TINE - Havro 48 HOUR RUN 90 P.

80 aD 70 ORY BULB o.

60 w

50

~ ~ WET BULB 0

2 4

6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TINE " Hovro 48 HOUR RUN

I

~

I

Page 15 3) 2M-AFA-P01 Essential AFW pump 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> endurance test data a)

Date of testing:

July 12, 1985 through July 14,

1985, and July 19, 1985.

b)

Bearing Temperatures

The limits for each bearing temperature, along with the maximum obtained temperature are listed below:

AFN-TE-59 (Limit AFN-TE-60 (Limit AFN-TE-83 (Limit AFN-TE-84 (Limit AFN-TE-85 (Limit 200'F max) 200 F max) 200'F max) 200'F max) 200'F max)

Max.

Max.

Max.
Max.
Max.

137'F (128.8'F)*

115'F (126.7'F)*

167'F 157'F 166 F

  • Maximum values while using hand held contact pyrometer (M&TE) for bearing surface temperatures.

c)

Flow Data:

AFA-POl was run on minimum recirculation during the 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> run.

Operations also used AFA-F01 to feed the steam generators while at the 565'F and 2250 psia test plateau.

d)

Vibration Data:

Data was collected using a

hand held vibration meter and probe.

The M&TE used was an IRD Model

/3350.

The maximum vibration limits are 5

mils and the actual vibrations recorded during the test are listed below.

Inboard Bearing:

.24

.46 mils Outboard Bearing:

.35.64 mils e)

Pump room temperature and humidity data:

Data was collected using a calibrated temperature and humidity meter (M&TE).

Temperature Range:

67.2'F to 80.5'F Humidity Range:

49.3% to 70.9/

The 48-hour endurance run demonstrated that 2M-AFA-P01 remained within design limits with respect to bearing temperatures and vibrati'on.

The test data also showed that the pump room ambient conditions (temperature, humidity) did not exceed environmental qualification limits for safety related equipment in the room.

The following plots made for the bearing temperatures versus time demonstrated that the design limits were not exceeded.

Plots were also made for the pump room temperature and humidity data versus time.

AJM:GEP:RLG:WHF:mg

~

2M-AFA-P01 AUXILIARYFEEO>lATER PUMP AFN-TE-59 TURBINE GOVERNOR ENO JOURNAL BEARING 170 160 BEARING SURFACE TENPERATURE H

8, TE USED WHILE AFN-TE-059 INOPERATIVE I

150 140 g

130 0

a 120 I

EU 5

110 100 90 8D 70 60 0

2 4

6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TINE - Hours 48 HOUR RUN 0

I I

HOUR RUN AFTER COOLDOWN

2M-AFA-PO1 AUXILIARY FEEOWATER PUMP AFN-TE-60 TURBINE COUPLING ENO JOURNAL BEARING Q

~

OCI lD 170 160 8EARINC SURFACE TEHPERATURE H L TE USED NIILE AFN-TE-060 INOPERATIVE 150 140 o

130 0

o 120 I

W 5

110 100 I

90 80 70 60 0

2 4

6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TIHE - Hours 48 HOUR RUN 0 I I

HOUR RUN AFTER COOLDOW

O.

J y,

2M-AFA-P01 AUXILIARYFEEDWATER PUMP AFN-TE-83 PUMP FREE ENO JOURNAL BEARING

\\

170 160 1SO 140 U.

s 130 a

120 I

IV 110 100 90 80 70 60 0

2 4

6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TlHE - Haves 48 HOUR RUN 1

I 0

1 1

HOUR RUN AFTER COOLDOMN

l'

2M-AFA-P01 AUXILIARYFEED>/ATER PUMP AFN-TE-84 PUMP COUPLING END 30URNAL BEARING

'7

~',

\\

170 160

~

150 140 g

130 o

120 I

5 110 100 I~

80 70 6D 0

2 4

6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TIME " Hours 48 HOUR RUM 0

1 I HOUR RUM hFTER COOLDOWH

2M-AFA-PQ 1 AUXILIARY FEEQWATER PUMP AFN-TE-85 PUMP THRUST BEARING 170 160 150 140 130 0at.

o 120 I

110 100 90 80 70 60 0

2 4

6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TINE Hours 48 HOUR RUN 0

1 1

HOUR RUN AFTER COOLOOMN

VR

2M-AFA-PO1 AUXILIARY FEEOWATER PUMP ROOM

- ENVIRONMENTAL QATA

\\

90 80 I

I H

70 y.

w 60 I-50 40 0

2 4

6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 tIME " Hours 48 HOUR RUN 90 P.

BO Cl 70 60 50 DRY BULB 0

?

4 6

8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 tIME - Hours 48 HOUR RUN

0 I'

V J

\\