Interim Deficiency Rept DER 84-30 Re Improper Documentation of Diesel Generator Components.Initially Reported on 840511.Bechtel & Cooper Energy Determining Corrective Action.Final Rept Expected by 840824
ML17298B045
Person / Time
Site: Palo Verde  
Issue date: 06/05/1984
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Bishop T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
ANPP-29669-TDS, DER-84-30, NUDOCS 8406180294
Download: ML17298B045 (8)


Text

~ $ )

~

~

Arizona Public Service Company June 5, 1984 ANPP-29669-TDS/TRB U. S. Nuclear Regulatory Commission Region V

Creekside Oaks Office Park 1450 Maria Lane Suite 210 Walnut Creek, CA 94596-5368 Attention: Mr. T. W. Bishop, Director Division of Resident Reactor Projects and Engineering Programs Sub)ect:

Interim Report DER 84-30 A 50.55(e) Potentially Reportable Deficiency Relating to Improper Documentation of Diesel Generator Components File:

84-019-026; D.4.33.2 Reference.

Telephone Conversation between P. Narbut and T. Bradish on May 11, 1984

Dear Sir:

The NRC was notified of a potentially reportable deficiency in the referenced telephone conversation.

At that time, it was estimated that a determination of reportability would be made within thirty (30) days.

Due to the extensive investigation and evaluation required, an Interim Report is attached.

It is now expected that this information will be finalized by August 24, 1984, at which time a complete report will be submitted.

Very truly yours,

~RVc E. E. Van Brunt, Jr.

APS Vice President Nuclear Production ANPP Project Director EEVB/TRB ru Attachment cc:

See Page Two

~

o( ~

Mr. T.

W. Bishop DER 84-30 Page Two CCQ Richard DeYoung, Director Office of Inspection and Enforcement U.

S. Nuclear Regulatory Commission Washington, D. C.

20555 T. G.

Wo ods, Jr.

D. B. Karner W. E. Ide D. B. Fasnacht A. C. Rogers L. A. Souza B. S. Kaplan D. E. Fowler T. D. Shriver C. N. Russo J. Vorees J.

R.

Bynum J.

M. Allen J. A. Brand C. Gehr W. J. Stubblefield W. G. Bingham R. L. Patterson R-W. Welcher H. D. Foster D. R. Haykinson L. E. Vorderbrueggen

-G. A. Fiorelli S.

R. Frost J. Self D. Canady Records Center Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500

Atlanta, GA 30339

~ ~, ( ~

i1 li II I

h t

INTERIM REPORT DER 84-30 POTENTIAL REPORTABLE DEFICIENCY ARIZONA PUBLIC SERVICE COMPANY (APS)

PVNGS UNITS 1, 2, 6 3 I. Potential Problem There are two (2) ASME Code Stamped "N" items (ASME Code Class

3) on each of the "A" and "B" trains.

They are:

1.

2MDGAE04 Lube Oil Cooler MRG S/N 9-20016-02-3 2.

2MDQAE05 Jacket Water Cooler MFG S/N 9-20016-01&

3.

2MDGBE04 Lube Oil Cooler MFG S/N 9-20016-02-2 4.

2MDGBE05 Jacket Water Cooler MFG S/N 9-20016&2-2 Parts that are non-conforming on each item listed above are:

1. Four (4) 1" dia. half (1/2) couplings (these are for three (3) thermowells and an isolation valve).
2. One'reducing bushing.

I'.

One isolation valve.

(V341, V342, V441, V442) 4.

Two (2) 3/4" dia. half (1/2) couplings for vent and drain lines).

5. Siz (6) attachment welds for items 1 and 4 (half couplings).

All of=the above parts are within the ASME Code boundaries established by P&ID 13-M-DGP-001, Rev.

10 and the vendor'Cooper Energy Services).

The N-1 Manufacturer 's Code Data Report (American Standard Heat Transfer Division) for each of the items (lube oil and

)acket water cooler) do not list these parts, nor is there any objective evidence supporting documentation, i. e., material certifications, weld documentation, etc. available in the files.

The isolation valve does not have a Code nameplate nor any identification marks.

Heat numbers are not visible, on the half couplings, and there are no weld identification numbers, nor the welders'dentification number, for the attachment welds.

Weld documentation for these welds are also not available.

II. Approach To and Status of Proposed Resolution Bechtel engineering is currently corresponding with Cooper Energy on this problem to determine reportability and technical justification for corrective action.

~

a(i

(

lt

Interim Report DZZ 84-30 Page Two III. Pro5ected Co-Metion of Corrective Action and Submittal of the Final Report Evaluation of this condition and submittal of the Final Report is forecast to be completed by August 24, 1984.

m $

~:

'(

il I

f