Text

. QQ REGy Wp

~ i 0

NUCLEAR REGULATORY COMMISSION REGION V 1450 MARIALANE,SUITE 210 WALNUTCREEK, CALIFORNIA94596 February 18, 1983 Docket No.

50-528 IE HQFIZZ ~

Arizona Public Service Company P. 0.

Box 21666

Phoenix, Arizona 85036 Attention:

Nr. E.

E.

Van Brunt, Jr., Vice President Nuclear Projects Management Gentlemen:

Attached for your information are the signature and summary pages for the investigation, report (Case Number 5-82-006) prepared

.by the Office of Investigations, Region V, for the investigation conducted June 16 through September 7, 1982, concerning allegations regarding post weld heat treatment.

Copies of the attached pages will also be placed in the NRC Public Document Room without a copy of the investigation report which is considered to be for "Official Use Only."

If you have any questions regarding this matter, please feel free to call on us Sincerely, D.

M. Sternberg, Chief '"

Reactor Projects Branch No.

Enclosure:

As stated SHOZG'i%TED OBIGXNM qevkkfioC Sz 8303110244 8302i8 PDR ADOCK OS000528 8

PDR