ML17297B581
| ML17297B581 | |
| Person / Time | |
|---|---|
| Site: | Palo Verde |
| Issue date: | 06/21/1982 |
| From: | Miraglia F Office of Nuclear Reactor Regulation |
| To: | Van Brunt E ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR |
| References | |
| NUDOCS 8206250359 | |
| Download: ML17297B581 (5) | |
Text
08 JUN 2 198K Docket Nos.:
50-528/50-529 and 50-530
~4 Mr. E.
E.
Van Brunt, Jr.
Vice President - Nuclear Projects Arizona Public Service Company Post Office Box 21666 Phoenix, Arizona 85036
Dear Mr. Van Brunt:
g~
J os
"++~~ ~~~
e Zgg
~oo Distribution:
Document Control (50-528/5 HRC PDR L PDR 6'RC NSIC LB5'3-Rdg.
FHi rag 1 i a JLee-MLicitra DEisenhut/RPurple Attorney,.OELD (REngleken IE ACRS (103
Subject:
Request for Additional Information - Palo Verde, Units 1, 2 and 3
Your letter of June 10, 1982 summarized recent developments that have occured concerning certain geologic features in 'the area of the Pal'o Verde site.
In order to determine the significance of these fea'ture's, we request that you provide the additional information discussed in the Enclosure.
Me request that within one week of receipt of this letter, you provide a date as to when the additional informati'on will'e submitted.
If you have any questions on this matter, please contact E. Licitra, the Project Manager.
Sincerely.
"prig'.nal sipvoa by praise J. HiraSlia" Frank J. Miraglia, Chief Licensing Branch No.
3 Division of Licensing
Enclosure:
Request for Additional Information cc w/enclosure:
See next page
, 8206250359 820621 PDR ADOCK 05000528 PDR 0FF1CE />
SURNAME/
0ATE f>
...NK.;..0.............BL ELicitra:c FM 1 i a 6/4//82 6
/82
~ ~ ~
~ ~ ~
~
~
~ ~ ~ ~ ~ ~ ~ ~
~
~
NRC FORM 318 80/80) NRCM 0240 OFFICIAL RECORD COPY
- USGPO: 1980-329-824
f)t
<<4 W '
gi \\"
t<r. 'F..
E.
Van Brunt, Jr.
Vice President Wuclear Projects
,Arizona Public Service Company P. 0.
Box 21666
- Phoenix, Arizona 85036'ALO'rp CC:
~
~
Arthur C. Gehr, Esq.
Snell 6 Wilmer 3100 Vailey Center
- Phoenix,
'-.izona 85073 Chari es S.
P i erson Assistant Attorney General 200 Stat Capitol 1700 West "ashi ngton
- Phoenix, Arizona 85007 Charles R. Kocher, Esq., Assistan't Counsel James A. Beoletto, Fsq.
Southern California Edison Company P. 0.
Box 800
- Rosemead, California 91770 Margaret Wall;er Deputy Director of Energy Programs Economic Planning and Development Office 1700 West Washington
- Phoenix, Arizona 85007 ter.
Rand L. Greenfield Assistant Attorney General Bataan memorial Building Santa Fe, Hew Mexico 87503 Resident inspector Palo Verde/NPS U.S. t/uclear Regulatory Commission P. 0.
Box 21324
- Phoenix, Arizona 85001 1<s.
P atri ci a Lee Houri han 6413 S. 26th Street
- Phoenix, Arizona 85040
RE(}UEST FOR ADDITIONAL INFORMATION PALO VERDE NUCLEAR GENERATING STATION, UNITS 1, 2 5 3 ARIZONA PUBLIC SERVICE COt/PANY DOCKET NOS.
STN 50-528/529/530 231.6 Geologic features, which may possibly be faults, have been 4
recently identified within approximately 8 to 13 miles of the Palo Verde Nuclear Generating Station by a Geologist with the Arizona Bureau of Geology and Mineral Technology.
Preliminary estimates indicate that at least some of the features (faults) may be of tectonic origin and may be capable - ranging from 10,000 perhaps 50,000 years old.
Conduct field studies and investigations as necessary in order to better understand the nature and age of the reported faulting.
For any feature which is determined to be a fault, determine whether it is capable.
If capable, determine the effect, if any, on the seismic design bases for'the Palo Verde plant.
0 0
>I I ~