ML17297A903

From kanterella
Jump to navigation Jump to search
Forwards Addl FSAR Input Re Control Room Habitability,In Response to Accident Evaluation Branch 810813 Request
ML17297A903
Person / Time
Site: Palo Verde  Arizona Public Service icon.png
Issue date: 10/02/1981
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Tedescco R
Office of Nuclear Reactor Regulation
References
ANPP-19066-JMA, NUDOCS 8110090325
Download: ML17297A903 (9)


Text

REGUL

'l'ORY INFORMATION DISTR I BUT N

SYSTEM (RIDS)

ACCESS IOA NBR: 8110 FACIL>>:STN"50-528 STN 50 529 STN"50 530 AUTHI,NA>>0IEI VAN BRU>>I>>Ti EI, E>,

REC IP ~ VA'>>>>IKI TEDESCCO~PR

~ LE

.090325 DOC ~ DATE': 81/10/02 NOTARIZED:= YES Pal o Verde Nucl ear Stati one Uni t 1~ Arizona Publ i Palo Verde Nuclear~ StationP Unit 2i Arizona Publi Palo Verde Nuclear Stations Unit 3E Arizona Publi AUTHOR-AFFILIATION Arizona Public Service'i Co.

R E C 'I P Z E NT A F FI L>>1 ATI0 i>>l Assistant Director>> for L>>i censing DOCKE<T' 0

05000529 05000530 SUBJKC%':: Forwards addi FSAR input re control room habitabilityi,in>>

re'spon>>se to Accident El>>>>aluation>> Branch 810813 request" OISTR~IBUTION COOEi:

B001S COPIES RECEEVEO:L>ITLKI: PSAR>>/FSAR AMDTS and'e>>i ated Correspondence >>VOTES:Standardized Plant.i cy:C Grimes Standardized Plant,i cylC>> Grimes Standardized Plant,l cy.'C>>, Grimes 05000528 05000529 05000530 REC IP J, KNT IO>> CODE/NAMKI ACT>>ION:I A/D>> L>>ICE>>>>ISNG L>>IC< BR 03( LA INTERNALi: ACCXD KVAL. BR26'HEM E'VG BR 11 COAE PERF BR 10. ELO GEQSC IKNCES 28 HYD/GEO< BR 30. IafI 06 IK'/EPLB>> 36" LICl QUAL>> BR 32". MECH ENG BR 1S OP LIC BR>> 34 PROC/TST REV 20. SS BR22! K4 F Oi T E>>>>I G B R25>> COPIES C,TTR ENCL>> 1 0 1 0 1 1 1 1 1 0 2' 2 2 3 3 3 1 1 1 1 1 1 1 1 1 1 1 1 RECIPIENT ID CODE/NAME L>>IC BR II>>3 BC 'ERRIGANPJ,04 AUX SYS BR 2'7 CONT SYS BR 09 EFF TR SYS BR12'QUIP QUAL BR13 HUM'ACT ENG 40 ILC SYS BR 16" IE/EPOB 35 L>>1 C GUID BR 33 NATL>> ENG BR 17 ~ip A POWER SYS BR 19 QA BR 21. REAC SYS BR 23 SIT'NAL BR 24 COPZK6 LTTR>> ENCL< 0 1 EXTERNALi: ACR6 LPOR NSI'C 41 0$ >> OS 16 16 1 1 1 FE>> IA REP DIV 39 NRC PDR 02'T'I S <CCTTI 4>>i(W 5'3 SS TO>>TAL NU>>>>IBER>> OF COPIES REQUIRED:: LiTTR 6 ENCL< N r. C ~ a o p STA. Mf@ HIM%IaaHKR P.o. BOX 21666 PHOENIX, ARIZONA86036 October 2, 1981 ANPP-19066-JMA/TFQ Mr. R. L. Tedesco Assistant, Director for Licensing Division of Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555

Subject:

cQ~t,'/gal 11 i o~T 3 )OS)-::

"~8 II0+KARRr~yo~

COhlhlI88I0N Palo Verde Nuclear Generating Statio (PVNGS) Units 1, 2 and 3

lg (

Docket Nos. STN-50-528/529/530 File:

81-056-026; 'G.1.10

Reference:

Letter from R. L. Tedesco, NRC, to E. E. Van Brunt, Jr.

dated August 13, 1981;

Subject:

Request for Additional Information PVNGS (Accident Evaluation Branch)

Dear Mr. Tedesco:

Attached is the revised response to NRC Question 450.18 for your use.

,This revision will be incorporated into the FSAR in an upcoming

'amendment.

Please contact me if you have any further questions on this matter.

Very truly your Cb~

nu 3'.

E. Van Brunt, Jr.

APS Vice President, Nuclear Projects ANPP Project Director EEVBJr/TFQ/ma Attachment cc:

J. Kerrigan (w/a)

P. Hourihan (w/a)

A. C. Gehr (w/a) 8110090325 811002 T'3.

PDR ADOCK 05000528,[

A PDRQ

I

'~

J ll

~

, F S

V. tl

$ 1I',

h Al" r p

E L'far e

STATE OF ARIZONA

)

) st COUNTY OF HARICOPA)

I; Edwin E. Van Brunt, Jr., represent'hat I am Vice President Nuclear Projects of Arizona Public Service Company, that the foregoing document has been signed by me on behalf of Arizona Public Service Company with full authority so to do, that I have read such document and know its contents, and that to the best of my knowledge and belief, the statements made therein are true.

Edwin E..Van Brunt, J '.~-"

~

CP

'981.

'vj/JI/

P Sworn to before me thi day of C/

Notary Public My Commission expires:

3

~ f e

I 4

J I

P o ~*

.'O,-

f(/

PVNGS FSAR uestion 6A.61 (NRC No. 450.18)

APPENDIX 6A (6.4)

Provide the following information required for the control room habitability evaluation:

(1) control room shielding including radiation streaming from penetrations,

doors, ducts, stairways, etc.:

(2)

Self-contained breathing apparatus availability (number)

(3) bottled air supply (hours supply)

(4) control room personnel capacity (normal and emergency)

(5) potassium iodide drug supply (6) control room emergency filtration system including the capability to maintain the control room pressur-ization at 1/8-inch water gauge, verification of isolation by test signals and damper closure times, and filter testing requirements.

RESPONSE

1)

The required information is provided in FSAR sec-tion 6.4.2.5 and LLIR section II.B.2.

2)

The required information is provided in paragraph M

of section 6.4.2.2.2.

3)

The required information is provided in paragraph M

of section 6.4.2.2.2

~

4)

There is no specific design limit on the number of personnel permitted in the control room under normal operation.

Refer to the PVNGS Security Plan for additional details of control room access restric-

, tions.

As noted in sections 6.4.1, 6.4.2.2.2 and 6.4.4.3, 6 persons can be accommodated in the control room in emergencies.

%4/e~

September 1981 6A.61-1 08-17-81 Amendment 6

PVNGS FSAR 5)

APPENDIX 6A Sufficient. potassium iodide wil3, be s

rj to supply 6 p6rsons for 7 days,

'as noted in paragraph D of section 6.4.4.3.

6)

The required information is provided in sec-tions 6.4.2.2, 6.4.2.3, 6.4.2.4, 6.4.3.2, 6.4.4.3, and 6.4.5.

Amendment, 6

6A.61-2 08-17-81 1981

J g ~ D