ML17297A857

From kanterella
Jump to navigation Jump to search
Forwards Comments on Util 810821 Responses to Open Items in Radiation Protection Area.Responses to Encl Comments Should Be Submitted within 7 Days & Contain Commitment to Include Responses in FSAR Amend 6
ML17297A857
Person / Time
Site: Palo Verde  
Issue date: 09/09/1981
From: Tedesco R
Office of Nuclear Reactor Regulation
To: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
References
NUDOCS 8109220890
Download: ML17297A857 (5)


Text

SEP 9

lg81 Docket Nos.:

50-528/50-529 and 50-530 Hr. E. E.

Van Brunt, Jr.

Vice President - Nuclear Projects Arizona Public Service Company P. 0.

Box 21666 Phoenix, Arizona 85036

Dear Hr. Van Brunt:

DISTRIBUTION:

Docket Files DEisenhut RPurple RTedesco FMiraglia JKerrigan JLee I&E (3)

WKreger BCC:

NRC PDR Local PDR NSIC TERA TIC ACRS (16)

Subject:

Comments on Responses to Radiation Protection Open Items C4 We have reviewed your letter dated August 21, 1981 which contained responses to open items in the radiation protection area.

Our comments are enclosed and have been previously discussed with Hr. guinn of your staff.

Your responses to the enclosed comments should be submitted within 7 days of receipt of this letter.

Your submittal should also include a commitment to include your responses in FSAR Amendment 6.

If'ou have any questions on this matter, please contact us.

Sincerely,

Enclosure:

As stated 084nal Agned by MXet L, TedeSCO Robert L. Tedesco, Assistant Director for Licensing Division of Licensing cc:

See next page DI:LB//3 OFFICE/

SURNAMEIp

'8-(n:ph 8/ 7

/8 WKreg r

/gg /

OATE Q

'oR 8~0 8>0~M ADOCN 05000528 j PDR.

AD:

3......".

'lia

~

~ e ~ ~ o g+

/

RT sco

~ L NRC FORM 318 (10-80) NRCM 0240 FFICIAL RECORD COPY US0 PO: 1981-333.980

0

'I I

80

~'NCLOSURE 1'OMMENTS ON'VNGS LETTER DATED AUGUST 21, 1981

/

Figures 13.1-6 and 13.1-7 should be revised to show that radiation protection section is a separate organization.

Section 13.1.3.1 does not specify the minimum requirements for the supervising radiation physicist (who is the RPM back-up).

Section 13.1.2.2,2.2 specified the minimum requirements.

a)

II'.B.2 - Does not state that:

"Personnel radiation exposures in vital areas,, during post-accident activities will meet the criteria of NUREG-0737 and GDC-19 design basis."

b)

II.F.1.3 - The location of the containment high-range monitors should be specified.

c)

III.D.3.3 - Does not state that a minimum of three (3) portable airborne iodine samplers will be available on the site..

P a)

The minimum requirements for station personnel described in Section 13.1.2 are keyed to ANSI N18.1-1971 as follows:

Insert A', Page 13.1-22, wordin for NOTE d for supervising, radiation: physicist is not inclu ed.

b).

Amended Section 13'.1,.2.3 does not show the number of radiation protection technicians assigned to each unit.

The original number

('6) of'adiation protection technicians should be increased and Section 13.1.2.3 and Figuire-13.1.6 should be revised accordingly.

The revised resume, for radiation protection supervisor (Mr. McDuffee) should be. provided..

Mr. E. E. Van Brunt, Jr.

Vice President -.Nuclear Projects Arizona Public Service Company P. 0. Box 21666 Phoenix, Arizona 85036 PALO VERDE CC Arthur C. Gehr, Esq.

Snell

& Wilmer 3100 Valley Center

Phoenix, Arizona 85073 Charles S. Pierson Assistant Attorney General 200 State Capitol 1700 West Washington Phoenix, Arizona 85007 Charles R. Kocher, Esq., Assistant Counsel James A. Beoletto, Esq.

Southern California'Edison Company P. 0. Box 800 Rosemead California, 91770 Margaret Walker Deputy Dfrector of Energy Programs Economic Planning and Development Office 1700 West Washington Phoenix,, Arizona 85007 Mr. Rand L. Greenfiel'd Assistant Attorney General Bataan Memorial Building Santa, Fe, New Mexico 87503 Resident. Inspector Pal'o Verde/NPS U.S. Nuclear Regulatory: Commission P.. 0.. Box 21324-Phoenix, Arizona 85001's; Patricia, Lee Hourihan 6413'.

26th Street.

Phoenix, Arizona-85040

C

,P