ML17296A679

From kanterella
Jump to navigation Jump to search
Forwards Interim Deficiency Rept Re Visual Insp of Circumferential Weld Joints on ASME Section Iii,Class 3 Piping Sys Between 2-4 Inches in Diameter
Date released: 07/31/2018 Download: ML17296A679


Interim Deficiency Rept Re Visual Insp of Circumferential Weld Joints on ASME Section Iii,Class 3 Piping Sys Between 2-4 Inches in Diameter.Caused by Incorrect Info on Drawing 13-P226-011.Welds Will Be re-inspected
ML17296A680
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 04/09/1980
From:
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
References
Download: ML17296A680 (4)
Forwards Interim Deficiency Rept Re Visual Insp of Circumferential Weld Joints on ASME Section Iii,Class 3 Piping Sys Between 2-4 Inches in Diameter
ML17296A678
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 04/10/1980
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: SPENCER G S
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
Download: ML17296A678 (6)