+gR Rgg+

~

.~C C

0 l

C.

/P UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.c. 20SS~I WASHINGTON PUBLIC POWER SUPPLY SYSTEM OOCKET NO. 50-397 NUCLEAR PROJECT NO.

2 AMENOMENT TO FACILITY OPERATING LICENSE Amendment No.

125 License No.

NPF-21 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

.The application for amendment by the Washington Public Power Supply System (licensee) dated February 8,

1994, as supplemented March 25, 19'94, complies with the standards and requirements of the Atomic.Energy Act of 1954, as amended (the Act) and the Commission's regulations set forth in 10 CFR Chapter I; 8.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can-be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's -regulations; 2.

O.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of,the Commission's regulations and all applicable requirements have been satisfied.

Accordingly, the license is amended by changes to the Technical Speci-fications as indicated in the attachment to this license amendment and paragraph 2.C.(2) of Facility Operating License No.

NPF-21 is hereby amended to read as follows:

940b290282 940bi'7 PDR ADDCK 05000397 P

'DR

I t

3.

(2)

Technical S ecificati'ons and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through Amendment No.

l25 and the Environmental Protectio'n Plan contained in Appendix B, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with. the Technical Specifications and the Environmental Protection Plan.

This amendment is effective on the date of issuance,

Attachment:

Changes to the Technical Specifications.

Date of Issuance:

June l7, 1994

'R THE NUCLEAR REGULATORY COMMISSION Theodore R. quay, Dire r

Project Directorate IV-3 Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation

ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO. 125 TO FACILITY OPERATING LICENSE NO.

NPF-21 DOCKET NO.'0-397 Replace the following pages of the Appendix A Technical Specifications with the enclosed pages.

The revised pages are identified by amendment number and contain vertical lines indicating the areas of change.

The corresponding

'overleaf pages are also provided to maintain document completeness.

REMOVE 3/4 6-24 INSERT 3/4 6-24

I' I

ia

TABLE 3.6.3-1 Continued PRIMARY CONTAINMENT ISOLATION VALVES VALVE FUNCTION AND NUMBER a.

Automatic Isolation Valves (Continued)

Reactor Core Isolation Cooling RCIC-V-8 RCIC-V-63 RCIC-V-76 Low Pressure Core Spray LPCS-V-12 High Pressure Core Spray HPCS-V-23 b.

Excess Flow Check Valves e

Containment Atmosphere PI-EFC-X29b P I-EFC-X29f PI-EFC-X30a P I-EFC-X30F PI-EFC-X42c PI-EFC-X42f P I-EFC-X61c PI-EFC-X62b P I-EFC-X69f PI-EFC-X78a I

VALVE GROUP a

10 MAXIMUM ISOLATION TIME Seconds 26 16 22 180 180 N.A.

l't f