TABLE 3. 3. 7. 5-1 (Continued)
ACCIDENT MONITORING INSTRUMENTATION 0 0'g DA CIO.'Q
%0 O%
cnM OO'Q'O~l t UQO, C) n Ifll I
M I
INSTRUMENT 14.
Neutron Flux:
RCIC Flow 16.
HPCS Flow 17.
LPCS Flow 18.
Standby Liquid Control System Flow 19.
Standby Liquid Control System Tank Level 20.
RHR Fl ow 21.
RRR Heat Exchanger Outlet Temperature 22.
Standby Service Mater Flow 23.
Standby Service Water Spray Pond Temperature 24.
RE(UIRED NUMBER OF CHANNELS 2
2 2
1 1
1 1
1 1/1 oop 1/heat exchanger 1/loop 2
MINIMUM CHANNELS OPERABLE 1
2
~'
2 1,
2
~ 1, 2
1, 2
1, 2
1, 2
1, 2
1/2 1 ~ 2 1-1/loop
~ 1/heat exchanger 1/1 oop 1
1, 2
1, 2
80 80 ao 80 80 80 80 80 80 ao 80 80 APPLICABLE OPERATIONAL COROITIORS ACTION A
Oz 0
I, CJA0 Cl.a O
V 25.
Emergency Ventilation Damper Position 26.
Standby Power and Other Energy Sources 27.
Primary Containment Valve Position 28.
Primary Containment Gross Radiation Monitors8 29.
30.
31.
Reactor Building G~lc cary-hfoaar4neaaa Q Sic~
2/duct 2/sorlrce 1/val ve 2
1/duct 1/source 1/1 ine 1,
2 1
2 1
2 2R 3
a 1, 2, 3
80 80 ao 81 81 8High range moni tors.
oltIe 4 eon,c, Llose~
w'"~R~
90 Joy s o4'L~ 'reLcu jo poue~ C ffowau
~4 l t t'5 o
~
o t 04l
~
wry r Pal a eagg k
~It ~
4 ~l calilor~ka e4 0;a
~T'aL uule "er l
pI o.peeler'>
ctutpo~>
f'Lc. p rotp a stows of Riage r.> Pi c+ae~
- 3. 0, Q at re, woF
~lpplt~Llc,
l1
,i
~ ~
1 TABLE 4.3.7. 5-1 (Continued)
ACCIDENT MONITORING INSTRUMENTATION SURVEILLANCE RE UIREHENTS INSTRUMENT 18.
Standby Liquid Control System Flow 19.
Standby Liquid Control System Tank Level 20.
RHR Flow 21.
RHR Heat Exchanger Outlet Temperature 22.
Standby Service Mater Flow 23.
Standby Service Mater Spray Pond Temperr'ature 24.
'25. 'mergency Ventilation Damper Position 26..
Standby Power and Other Energy Sources 27..-. Primary Containment Valve Position 28.
Primary Containment Gross Radiation Monitors 29.
30.
CHANNEL CHECK H
M M
M M
M M
M M
CHANNEL CALIBRATION R
R R
R" APPLICABLE OPERATIONAL CONDITIONS 1
2 1
2 1
2 1
2 1,
2 1
2 1
2 1
2 1
2 1, 2, 3
31.
Reactor Building M
Egt.'l M )Ko~;Qr~~ Syskc BLE NOTATION 4+
1 "CHANNEL CALIBRATION'shall consist of an electronic calibration of the channel, not including the detector, for range decades above 10 R/h and a one point calibration check of the detector below 10 R/h with an installed or portable gamma source.