REGULAT
INFORMATION DISTRIBUTION
STEM (RIDS)
1
!
ACCESSION
NBR: 8803080042
DOC. DATE: 88/03/02
NOTARIZED:
NO
DOC)<ET
FACIL: 50-397
WPPSS Nuclear Pro Ject>
Unit 2>
Washington Public
Poee
050003)7
AUTH. NAME
AUTHOR AFFILIATION
ZIMMERMANiR.
Region
5i
Ofc of the Director
REC IP. NAME
RECIPIENT AFFILIATION
SORENSEN> G. C.
Washington Public Poeer
Supply
System
SUBJECT:
Ack receipt of 880129 ltr informing
NRC of steps
taken to
correct violations noted
in Insp
Rep t 50-397/87-19. Comments
on items requiring addi clarification encl.
DISTRIBUTION CODE:
IE01D
COPIES
RECEIVED: LTR
ENCL
SIZE:
TITLE: General
(50 Dkt)-Insp Rept/Notice
of Violation Response
NOTES:
REC IP IENT
ID CODE/NAME
PD5
INTERNAL:
NRR MORISSEAUi D
NRR/DLPG/G*B10A
NRR/DREP/EPB10D
NRR/DRIS DIR9'A2
QE LIEBERMANiJ
EG F~LE
01
COPIES
LTTR ENCL
RECIPIENT
ID CODE/NAME
SAMWQRTH1R
DEDRQ
NRR/DLPG/PEB11B
NRR/DOEA DIR11E
NRR/DREP/RPB10A
NRR/PMAS/ILRB12
OGC 15-B-18
RES/DRPS
DIR
CQP IES
LTTR ENCL
TERNAL:
LPDR
NRC
TOTAL NUMBER OF COPIES
REQUIRED:
LTTR
22
ENCL
Docket No. 50-397
Washington Public Power Supply System
P.
0.
Box 968
3000 George Washington
Way
Richland, Washington
99352
Attention:
Mr.
G.
C. Sorensen,
Manager
WNP-2 Regulatory
Programs
Gentlemen:
Thank you for your letter dated January
29, 1988, in response
to our Notice
of Violation and Inspection
Report
No. 50-397/87-19,
dated
December
8, 1987,
informing us of the steps
you have taken to correct the items which we
brought to your attention,
As a result of our review of your responses,
we
have determined that additional clarification is needed
addressing
specific
items to Appendix A.
Our comments to these
items are enclosed.
Your
corrective actions will be verified during a future inspection.
Your cooperation with us is appreciated.
~ii&(na~>~ '
Attachment:
(as stated)
bcc w/copy of letter dated 1/29/88:
G.
Cook
A. Johnson
B. Faulkenberry
J. Martin
docket file
Resident
Inspector
Project Inspector
State of WA
LFMB
R.
Zimmerman, Chief
Reactor Projects
Branch
bcc w/o copy- of letter dated 1/29/88:
M. Smith
REGION V
WWagner/dot
ic
rds
imme
man
3/ 2/88
3/A /88
3
88
RE/VEST
C
Y ]
RE
EST
COPY ] REQUEST
COPY ]
YES /
0
ES /
NO
YES /
NO
8803080042 '880302
ADOCK 05000397
G
S
ND TO
]
/
NO
g
I
f~
I
0
APPENDIX A COMMENTS
Response
to A. 1:
(Page
2 of 21)
Under "Corrective Action to be Taken" it is stated that
no further corrective action is planned.
Can
we assume
that the actions
discussed
in Appendix
C are intended to
correct the root cause of this violation?
Response
to A.2:
(Page
3 of 21)
Under "Corrective Action Taken" your discussion
does
not
address
those currents
which were too high for the trip
times
documented
in the surveillance tests,
e. g., valve
RRC-V-16A.
Response
to B:
(Page
4 of 21)
The corrective action taken
does not describe
any action
to check for similar problems
on other tanks at the site,
nor is the root cause
addressed,
e. g., the
need for
effective independent
design
review.
Response
to C.2:
(Page
8 of 21)
Same
comment
as to A.l.
Response
to C.3:
(Page
10 of 21)
Your response
states
that the present installation of two
electrical terminations is acceptable
for drain lines.
This appears
contrary to the manufacturer's
(Raychem)
recommendation
that drain line terminations
should
be
covered with Heat Shrinkable
Tubing (HST).
Therefore,
we
request that you provide additional clarification
supporting your position that these drain lines are
acceptable
as currently installed.
Also, include
an
explanation
addressing
how circuit integrity is
maintained if the exposed wire is not properly covered
with HST.
Response
to C.4:
(Page ll of 21)
Your discussion
under "Corrective Steps
Taken"
does not
recognize
the
need for enhanced sensitivity by plant
operators
and supervision to improper plant
modifications.
This is more than
a housekeeping
issue.