m CONTAINMENT SYSTEMS SURVEILLANCE REOUIREHENTS Continued
()
d.
Type B and C tests shall be conducteg with gas at P
, 34.7 psig," at intervals no greater than 24 months except for test$ involving:
1.
Air locks, 2.
Hain steam line isolation valves, 3.
4, Valves pressurized with fluid from a seal
- system, s
ECCS and RCIC containment isolation valves in hydrostatically tested lines which penetrate the primary containment, and 5.
Purge supply and exhaust isolation valves with resilient seal s.
e.
g.
h.
Air locks shall be tested and demonstrated OPERABLE per Surveillance Requirement 4.6.1.3.
Hain steam line isolation valves shall be leak tested at least once per 18 'months.
Leakage from isolation salves that are sealed with fluid from a seal system may be excluded, subject to the provisions of Appendix J,Section III.C.3, when determ>ning the combined leakage rate provided the seal system and valves're~pressurized to at least 1.10 P
38.2 psig, and the seal system capacity is adequate to maintain system pressure for at least 30'davs.
f~
ECCS and RCIC containment isolation<valves in hydrostatically tested lines which pentrate the primary containment shall be leak tested at least once per 18 months.
i.
Purge supply and exhaust isolation valves with resilient material seals shall be tested and demonstrated OPERABLE per Surveillance Requirements 4'. 1.8. 2 and 4. 6. 1.8. 3 ~
j.
The provisions of Specification 4.0.2.are not applicable to 24-month or 40 ~ 10 month surveillance intervals.
"Unless a hydrostatic test is required per Table 3.6.3-1.