EGO:

AP-FW. 1 TITLE:

PARTIAL OR COMPLETE LOSS OF MAIN FEEDWATER REV 7

PAGE 1 of 6 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE

- /

-, 9 PLANT SUPERINTENDENT EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY:

9'R ooaa 91OaOZ

@DOCK 05OQQpy P

PDR

t

+4'

EOP:

AP-FW. 1 T!TLE:

PARTIAL OR COMPLETE LOSS OF MAIN FEEDWATER REV 7

PAGE 2 of 6 A.

PURPOSE This procedure provides the steps necessary to respond to a MFW system malfunction resulting in a decrease in or complete loss of main feedwater.

B.

ENTRY CONDITIONS/SYMPTOMS 1.

SYMPTOMS The symptoms of PARTIAL OR COMPLETE LOSS OF OF MAIN FEEDWATER are; a.

Annunciator G-3(5),

S/G A(B) LEVEL DEVIATION i74, lit, or b.

Annunciator G-19(21),

S/G A(B) FF < SF CHANNEL ALERT 0.8 x 10~ LB/HR, lit, or c.

Annunciator G-20(22),

S/G A(B)

LO LEVEL CHANNEL ALERT 304, lit or d.

Annunciator K-18, MAIN FEEDWATER PUMPS TRIPPED, lit, or e.

Low indicated MFW pump suction flow on 1 pump, or f.

MFW pump indicates tripped, or g.

MFW pump discharge valve indicates shut.

c'Ãh

EOP:

AP-FW. 1 TITLE:

PARTIAL OR COMPLETE LOSS OF MAIN FEEDWATER REV:

7 PAGE 3 of 6 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED CAUTION IF., AT ANY TIME DURING THIS PROCEDURE, A REACTOR TRIP OR SI OCCURS, E-O, REACTOR TRIP OR SAFETY INJECTION, SHALL BE PERFORMED.

NOTE:

Step 1 is an IMMEDIATE ACTION step.

O 1

Check MFW Requirements:

a.

Power - GREATER THAN 50X

b. Both MFV pumps - RUNNING c.

Go to Step 3

a. IF power less than 50X, THEN go to Step 2.
b. IF only one MFV pump has
tripped, THEN perform the following:
1) Start all 3 AFV pumps and verify flow.
2) Decrease power rapidly to less than 50X.

3)

Go to Step 3.

IF both MFV pumps have tripped, THEN ensure reactor trip and go to E-O, REACTOR TRIP or SAFETY INJECTION.

g A.

Qh

EOP:

AP-FW.1 TITLE:

PARTIAL OR COMPLETE LOSS OF MAIN FEEDWATER REV 7

PAGE 4 of 6 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 2 Verify At Least One MFW Pump RUNNING Perform the following:

a. Start all 3 AFV pumps and verify flow.
b. IF turbine previously operating, THEN verify turbine trip and go to AP-TURB.1, TURBINE TRIP WITHOUT RX TRIP REQUIRED OR E-O, REACTOR TRIP or SAFETY INJECTION.

IP turbine was NOT previously operating, THEN go to Step 5.

3 Verify MFW Pump Suction Pressure GREATER THAN 185 PSIG Perform the following:

a. Verify standby condensate pump running, if required.
b. Verify condensate bypass valve open.
c. Place trim valve controller to manual and close trim valves.
d. Check if condensate booster pumps have tripped and start as necessary.

4 Verify Adequate MFW Flow:

o A MPV flow - GREATER THAN OR EQUAL TO A STEAM PLOV o

B MFV flow - GREATER THAN OR EQUAL TO B STEAM FLOW Check MFV regulating valves controlling in AUTO.

IP NOT, THEN control MFW flow in MANUAL.

h IF MFV flow can NOT be controlled, THEN, trip the turbine and go to AP-TURB.1, TURBINE TRIP WITHOUT RX TRIP REQUIRED, or E-O, REACTOR TRIP or SAFETY INJECTION.

r t

'C1

~a Q

I I

i

EGA:

AP-FW. 1 TITLE:

PARTIAL OR COMPLETE LOSS OF MAIN FEEDWATER REV:

7 PAGE 5 of 6 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 5

Check Both S/G Levels GREATER THAN 17< AND TRENDING TO PROGRAM LEVEL IF S/G levels can NOT be restored, THEN trip the reactor AND go to E-O, REACTOR TRIP or SAFETY INJECTION.

6 Establish Stable Plant:

Conditions:

a.

Tavg - TRENDING TO TREF

a. Restore Tavg to normal:
1) Control rods controlling in AUTO.

IF NOT, THEN place rod control bank selector switch to MANUAL and adjust control rods, as necessary.

2) Borate if required for power reduction.

b.

PRZR pressure

- BETWEEN 2210 PSIG AND 2260 PSIG

b. Ensure PRZR heaters and spray operating as required, OR if necessary control heaters and spray manually. If PRZR pressure can NOT be controlled, THEN refer to AP-PRZR.1 ABNORMAL PRESSURIZER PRESSURE.
c. Narrow range S/G levels-TRENDING TO PROGRAM LEVEL
c. Ensure MFV regulating valves controlling in AUTO, OR control feed water in MANUAL.

I 4

, i I L

N

>Cq IJl*

E+~

Fq p~,j mV

EOP:

AP-FW.1 TITLE:

PARTIAL OR COMPLETE LOSS OF MAIN FEEDWATER REV:

7 PAGE 6 of 6 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 7

Check Status Of MFW Control Malfunction a.

Feedwater control malfunction-IDENTIFIED

b. Restore feedvater control system to AUTO
c. Verify all AFV pumps OFF vith svitches in AUTO
a. Continue to control feedwater as necessary.

VHEN malfunction identified, THEN do Steps 7b and c.

c. Stop running AFV pumps and place in AUTO.

NOTE-'efer to 0-9.3, NRC IMMEDIATE NOTIFICATION, for reporting requirements.

8 Notify Higher Supervision 9

Return To Procedure Or Guidance In Effect

-END-

I I

EOP:

ES-1.3 TITLE:

TRANSFER TO COLD LEG RECIRCULATION REV 10 PAGE 1 of 18 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE T SUPERINTEN EN EFFE TI E DATE QA NON-QA REVIEWED BY:

CATEGORY 1.0 6INNASTATION START:

DATE TIME CO,"':

i-'DIETED'ATE

.C l4t g

EOP:

ES-1.3 TRANSFER TO COLD LEG RECIRCULATION REV 10 PAGE 2 of 18 A.

PURPOSE This procedure provides the necessary instructions for transferring the Safety Injection system and Containment Spray system to recirculation modes of operation.

B.

ENTRY CONDITIONS/SYMPTOMS 1.

ENTRY CONDITIONS.This procedure may be entered from:

a.

E-l, LOSS OF REACTOR OR SECONDARY COOLANT, Step 20, on low RWST level.

b.

ECA-2.1, UNCONTROLLED DEPRESSURIZATION OF ALL STEAM GENERATORS, Step 10, on low RWST level.

c.

Other procedures whenever RWST level reaches the switchover setpoint (284).

Pl rq 4

f$ 8

EOP:

ES-1.3 TITLE:

TRANSFER TO COLD LEG RECIRCULATION REV 10 PAGE 3 of 18 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED CAUTION o

INJECTION FLOV TO THE RCS MUST BE MAINTAINEDAT ALL TIMES.

o IF OPFSITE POVER IS LOST AFTER SI RESET, THEN SELECTED SV PUMPS AND ONE CCW PUMP WILL AUTO START ON EMERGENCY D/G.

MANUAL ACTION VILL BE REQUIRED TO RESTART SAFEGUARDS EQUIPMENT.

o CONSULT VITH HEALTH PHYSICS BEFORE DISPATCHING PERSONNEL TO AUXILIARY BUILDING.

NOTE:

FOLDOUT page should be open and monitored periodically.

1 Verify CNMT Sump B Level GREATER THAN 113 INCHES IP RWST level is less than 28X AND CNMT sump B level is less than 113 inches, THEN go to ECA-1.2, LOCA OUTSIDE CONTAINMENT, Step l.

NOTE:

Steps 2 through 8 should be performed without delay.

PR procedures should not be implemented prior to completion of these steps.

2 Reset SI

1,

EOP:

ES-1.3 TRANSFER TO COLD LEG RECIRCULATION REV:

10 PAGE 4 of 18 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 3 Verify Adequate SW Flow To CCW Hx:

a. Verify at least two SW pumps-RUNNING
a. Perform the following:
1) Verify adequate power to operate two SW pumps (258 kw per pump).

IF NOT, THEN shed sufficient non-essential loads.

~ Charging pumps

~ IA compressors

~ PRZR heaters

~ Rx compartment cooling fans

~ Control rod shroud fans

b. Verify AUX BLDG SW isolation valves -

OPEN

~ MOV-4615 and MOV-4734

~ MOV-4616 and MOV-4735

2) Ensure two SW pumps running.
b. Perform the following:
1) Dispatch AO to locally open valves several turns to minimize hydraulic shock.

2)

WHEN notified that both valves in a set partially open THEN manually open valves.

t l

ky

~i

EOP:

ES-1.3 TITLE:

TRANSFER TO COLD LEG RECIRCULATION REV 1O PAGE 5 of 18 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 4 Establish Conditions For RHR Suction Swapover:

a. Place switch for MOV-856, RHR pump suction from RWST, to OPEN (spring returns to AUTO)
b. Establish CCW flow to RHR Hxs:
1) Check both CCW pumps-RUNNING
2) Open CCW valves to RHR Hxs

~ MOV-738A

~ MOV-738B

1) Start CCW pumps as power supply permits.
2) Dispatch AO to locally open valves.

CAUTION ANY PUMPS TAKING SUCTION PROM RWST SHOULD BE STOPPED UPON REACHING RWST LO-LO LEVEL ALARM.

5 Check IF Unnecessary Pumps Can Be Stopped:

a. Three SI pumps - RUNNING
b. Stop SI pump C and place both switches in PULL STOP
c. Both CNMT spray pumps - RUNNING
d. Pull stop CNMT spray pump on emergency D/G with maximum load e.

Stop both RHR pumps and place in PULL STOP a.

Go to Step 5c.

c. Pull stop any idle CNMT spray pump and go to Step 5e.

K%1 F>>

I.

EOP:

ES-1.3 TRANSFER TO COLD LEG RECIRCULATION REV:

10 PAGE 6 of 18 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED NOTE:

CCW Hx SW outlet valves should be opened equally to distribute flow evenly to both CCW Hxs.

6 Dispatch AO To Locally Perform The Following:

a. Ad)ust Total SW Plow To CCW Hxs To -

BETWEEN 5000 GPM AND 6000 GPM

~ V-4619

~ V-4620

a. IP greater than 5000 gpm can NOT be established, THEN perform the following as necessary to establish greater than 5000 gpm:
1) Start additional SW pumps as power supply permits (258 kw each).
2) Isolate SW to screenhouse and air conditioning headers.

~ MOV-4609 and MOV-4780

~ MOV-4663 and MOV-4733

3) Dispatch AO to locally isolate SW return from SPP Hxs:
b. Close breaker for RHR pump suction from RWST

~ SPP Hx A (V-4622)

~ SPP Hx B (V-8634 and V-8685)

4) Verify SW portions of Attachment SD-1 are complete.

~ MOV-856>

MCC C position 10C

Cet V

Qt kl

~t

'0/

0

EOP:

ES-1.3 TRANSFER TO COLD LEG RECIRCULATION REV:

10 PAGE 7 of 18 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 7 Verify RHR System Alignment:

a. Verify the following valves-CLOSED o

RHR suction valves from loop A hot leg

~ MOV-700

~ MOV-701

a. Ensure at least one suction valve and one discharge valve closed.

o RHR discharge valves to loop B cold leg

~ MOV-720

~ MOV-721

b. Verify the following valves-OPEN o

RHR pump suction valves

~ MOV-704A

~ MOV-704B o

RHR pump discharge to Rx vessel deluge valves

~ MOV-852A

~ MOV-852B

b. Ensure at least one valve in each set open.

o RHR suction from sump B

(inside CNMT)

~ MOV-851A

~ MOV-851B

c. Verify RCDT pump suction valves from sump B - CLOSED

~ MOV-1813A

~ MOV-1813B

c. Manually close valves.

~')

I 1

EOP:

ES-1.3 TRANSFER TO COLD LEG RECIRCULATION REV 10 PAGE 8 of 18 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 8 Initiate RHR Sump Recirculation:

a. Close RWST outlet valve to RHR pump suction (MOV-856) b.

Open RHR suction valves from sump B (outside CNMT)

~ MOV-850A

~ MOV-850B

a. Dispatch AO to locally close valve and continue with Step 8b.
b. Perform the following:
1) Ensure at least one RHR suction path from sump B

aligned:

o MOV-850A and MOV-851A-OPEN

-OR-o MOV-850B and MOV-851B-OPEN

2) Verify both RHR pump suction crosstie valves open.

~ MOV-704A

~ MOV-704B

c. Start RHR pumps with suction established from sump B (Refer to Attachment RHR SYSTEM)
3) Verify sump B suction established to operable RHR pump (Refer to Attachment RHR SYSTEM).

IF NOT, THEN go to ECA-1.1, LOSS OF EMERGENCY COOLANT RECIRCULATION, Step l.

c. IF no RHR pump can be started, THEN go to ECA-1.1, LOSS OF EMERGENCY COOLANT RECIRCULATION, Step l.

yt wl "1

EOP:

ES-1.3 TRANSFER TO COLD LEG RECIRCULATION REV 10 PAGE 9 of 18 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 9

Check RWST Level LESS THAN 154 DO NOT continue with this procedure until RUST level is less than 15X.

10 Stop All Pumps Supplied From RWST a.

Stop all SI pumps and place in PULL STOP

b. Stop all charging pumps
c. Reset CNMT spray if necessary
d. Stop operating CNMT spray pump(s) and place in PULL STOP
e. Close CNMT spray pump discharge valves

~ MOV-860A

~ MOV-860B

~ MOV-860C

~ MOV-860D

tI'.v

~r I

EOP:

ES-1.3 TITLE:

TRANSFER TO COLD LEG RECIRCULATION REV 10 PAGE 10 of 18 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED CAUTION SI PUMPS SHOULD BE STOPPED IF RCS PRESSURE IS GREATER THAN THEIR SHUTOFF HEAD PRESSURE.

11 Align SI And CNMT Spray For Sump Recirculation:

a. Verify SI pump suction valves from BASTs - CLOSED

~ MOV-826A and MOV-826B

~ MOV-826C and MOV-826D a.

Ensure at least one valve in each flowpath closed.

b. Close RVST outlet valves to SI and CNMT spray pumps (turn on DC power key switches)

~ MOV-896A

~ MOV-896B

b. Ensure at least one valve closed.
c. Close SI pump RECIRC valves

~ MOV-898

~ MOV-897

c. Ensure at least one valve closed.
d. Verify SI,pump suction valves from EST - OPEN
d. Ensure at least one valve open.

~ MOV-825A

~ MOV-825B e.

Open RHR Hx outlet valves to SI and CNMT spray pump suction

~ MOV-857A

~ MOV-857B

~ MOV-857C

e. Ensure operating RHR pump(s) aligned to SI and CS pump suction header (Refer to Attachment RHR SYSTEM).

~

EOP:

ES-1.3 TRANSFER TO COLD LEG RECIRCULATION REV 10 PAGE 11 of 18 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED NOTE:

SI pump C is preferred since it delivers to both lines.

12 Check If SI Pump Should Be Started:

a.

Check the folloving:

o Core exit T/Cs - GREATER THAN REQUIREMENTS OF FIGURE RHR INJECTION

a. IF RVLIS level (no RCPS) greater than 43X [46X adverse CNMT],

THEN go to Step 13.

-OR-o RCS pressure

- GREATER THAN 225 psig [425 psig adverse CNMT]

b. Start one SI pump

8~t T

y. w7

EOP:

ES-1.3 TRANSFER TO COLD LEG RECIRCULATION REV:

10 PAGE 12 of 18 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 13 Check If CNMT Spray Is Required:

a.

CNMT pressure

- GREATER THAN 37 PSIG

b. Start one CNMT spray pump c.

Open NaOH tank outlet valves for running pump

~ AOV-836A, pump A

~ AOV-836B, pump B

d.

Open one CNMT spray pump discharge valve for running pump

~ MOV-860A or MOV-860B, pump A

~ MOV-860C or MOV-860D, pump B

e.

VHEN CNMT pressure less than 32 psig, THEN close discharge valve and PULL STOP CNMT spray pump

a. Perform the following:
1) IF CNMT spray previously
actuated, THEN consult TSC to determine if CNMT spray should be restarted.
2) Go to Step 14.

14 Verify Adequate Core Cooling:

o Core exit T/Cs - STABLE OR DECREASING o

RVLIS level (no RCPs)

- STABLE OR INCREASING o

RVLIS level (no RCPs) - GREATER THAN 43X [46X adverse CNMT]

IF both RHR pumps running, THEN ensure two SI pumps running.

IF only ONE RHR pump running, THEN perform the following:

a. Ensure at least one SI pump running.

b.

VHRN CNMT spray pumps stopped, THEN start another SI pump as necessary.

l i 1

c

EOP:

ES-1.3 TITLE:

TRANSFER TO COLD LEG RECIRCULATION REV 10 PAGE 13 of 18 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED CAUTION IP CST LEVEL DECREASES TO LESS THAN 5 FEET, THEN ALTERNATE VATER SOURCES POR AFV PUMPS VILL BE NECESSARY (REFER TO ER-AFV.l, ALTERNATE WATER SUPPLY TO APW PUMPS).

15 Check Intact S/G Levels:

a. Narrow range level - GREATER THAN 5X [25X adverse CNMT]
b. Control feed flow to maintain narrow range level between 17X

[25X adverse CNMT] and 50X

a. Maintain total feed flow greater than 200 gpm until narrow range level greater than 5X [25X adverse CNMT] in at least one

S/G.

V5 hatt

EOP:

ES-1.3 TITLE:

TRANSFER TO COLD LEG RECIRCULATION REV:

10 PAGE 14 of 18 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 16 Establish Normal Shutdown Alignment:

a.

Check condenser

- AVAILABLE

b. Perform the following:

o Open generator disconnects

~ 1G13A71

~ 9X13A73

a. Dispatch AO to perform Attachment SD-2.

o Place voltage regulator to OPP o

Open turbine drain valves o

Rotate reheater steam supply controller cam to close valves o

Place reheater dump valve switches to HAND o

Stop all but one condensate pump

c. Verify adequate Rx head cooling:
1) Check IA to CNMT - AVAILABLE
2) Verify at least one control rod shroud fan - RUNNING
3) Verify one Rx compartment cooling fan - RUNNING
d. Verify Attachment SD COMPLETE 1)

Go to Step 16d.

2) Manually start one fan as power supply permits (45 kw)
3) Perform the following:

o Dispatch AO to reset UV relays at MCC C and MCC D.

o Manually start one fan as power supply permits (23 kw)

P>

V

~

EOP:

ES-1.3 TRANSFER TO COLD LEG RECIRCULATION REV 10 PAGE 15 of 18 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 17 Check If Emergency D/Gs Should Be Stopped:

a. Verify AC emergency busses energized by offsite power:

o Emergency D/G output breakers OPEN o

AC emergency bus voltage-GREATER THAN 420 VOLTS

a. Try to restore offsite power (Refer to ER-ELEC.1, RESTORATION OF OFFSITE POVBR).

o AC emergency bus normal feed breakers

- CLOSED

b. Stop any unloaded emergency D/G and place in standby (Refer to Attachment D/G STOP)

g4" I>>

EOP:

ES-1.3 TRANSFER TO COLD LEG RECIRCULATION REV 10 PAGE 16 of 18 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 18 Check If SI ACCUMs Should Be Isolated:

a. Both RCS hot leg temperatures-LESS THAN 400'F
b. Dispatch AO to locally close breakers for SI ACCUM discharge valves
a. Continue with Step 19.

%HEN both RCS hot leg temperatures less than 400'F, THEN do Steps 18b through d.

~ MOV-841, MCC C position 12F

~ MOV-865, MCC D position 12C

c. Close SI ACCUM discharge valves

~ ACCUM A, MOV-841

~ ACCUM B, MOV-865 d; Locally reopen breakers for MOV-841 and MOV-865

c. Vent any unisolated ACCUMs:
1) Open vent valves for unisolated SI ACCUMs.

~ ACCUM A, AOV-834A

~ ACCUM B, AOV-834B

2) Open HCV-945.

~,

a~

r,r

EOP:

ES-1.3 TRANSFER TO COLD LEG RECIRCULATION REV:

10 PAGE 17 of 18 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED CAUTION IF FUEL DAMAGE IS SUSPECTED, MAINTAIN S/G PRESSURE SLIGHTLY GREATER THAN RCS PRESSURE.

19 Check If Intact S/Gs Should Be Depressurized To RCS Pressure:

a.

RCS pressure

- LESS THAN INTACT S/G PRESSURES

b. Check S/G radiation - NORMAL o

Steamline Monitors (R-31, R-32) o Direct HP to sample S/Gs for activity c.

Dump steam to condenser from intact S/G(s) until S/G pressure less than RCS pressure a.

Go to Step 20.

b.

Do NOT dump steam from a S/G with high radiation.

Isolate feed flow to a S/G with high radiation.

c. IF steam dump to condenser NOT available, THEN dump steam using intact S/G ARVs until S/G pressure less than RCS pressure.

20 Consult TSC to Determine If Rx Vessel Head Should Be Vented NOTE:

The TSC should be consulted before changing recirculation lineups.

21 At 19 HOURS After Event Initiation, Perform Steps 22 through 24 Consult TSC to evaluate long term plant status.

t,

<<'k>>,

tg

EOP:

ES-1.3 TRANSFER TO COLD LEG RECIRCULATION REV 10 PAGE 18 of 18 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 22 Place CNMT Spray Pumps In PULL STOP 23 Verify Two SI Pumps RUNNING Manually start pumps.

24 Check Core Exit T/Cs LESS THAN REQUIREMENTS OF FIGURE RHR INJECTION Perform the following:

a. Manually open both PRZR PORVs and block valves.
b. Verify core exit T/Cs decreasing to less than requirements of Figure RHR INJECTION.

IF NOT; THEN dump steam from intact S/Gs until core exit T/Cs less than required.

25 Consult TSC To Evaluate Long Term Plant Status

-END-

EOP:

ES-1.3 TRANSFER TO COLD LEG RECIRCULATION REV 10 PAGE 1 of 1 ES-1.3 APPENDIX LIST TITLE PAGES 1)

RED PATH

SUMMARY

2)

FIGURE RHR INJECTION 3)

ATTACHMENT D/G STOP 4)

ATTACHMENT SD-1 5)

ATTACHMENT SD-2 6)

ATTACHMENT RHR SYSTEM 7)

FOLDOUT

-.al l~

lw

ES-1.3 TRANSFER TO COLD LEG

= RECIRCULATION REV:

10 PAGE 1 of 1 RED PATH

SUMMARY

a.

SUBCRITICALITY Nuclear power greater than 54 b.

CORE COOLING Core exit T/Cs greater than 1200'F

-OR-Core exit T/Cs greater than 700'F AND RVLIS level (no RCPs) less than 434

[464 adverse CNMT]

c.

HEAT SINK Narrow range level in all S/Gs less than 54

[254 adverse CNMT] AND total feedwater flow less than 200 gpm d.

INTEGRITY Cold leg temperatures decrease greater than 100'F in last 60 minutes AND RCS cold leg temperature less than 285'F e.

CONTAINMENT CNMT pressure greater than 60 psig

kai I\\I 4+'.',)

p l Apr

~N(

1&+

if I hl

EOP:

ES-1. 3 T1TLE:

TRANSFER TO COLD LEG RECIRCULATION REV 10 PAGE 1 of 1 CORE EXIT TEMPERATURE ('F) 600 FIGURE RHR INJECTION 550 TEMPERATURE INCREMENTS 10'F 500 450 400 350 300 250 200 10 20 30 40 CONTAINMENT PRESSURE (PSIG)

CNMT PRESSURE INCREMENTS 1 PSIG 50 60

fa 1

1

EOP:

ES-1.3 TRANSFER TO COLD LEG RECIRCULATION REV 10 PAGE 1 of 1 FOLDOUT PAGE 1.

SI REINITIATION CRITERIA IF EITHER condition listed below occurs, THEN operate SI pumps manually as necessary:

o Core exit TCs GREATER THAN REQUIREMENTS OF FIGURE RHR INJECTION OR o

RVLIS level LESS THAN 434

[464 adverse CNMT]

2.

AFW SUPPLY SWITCHOVER CRITERION IF CST level decreases to less than 5 feet, THEN switch to alternate AFW water supply (Refer to ER-AFW.l, ALTERNATE WATER SUPPLY TO AFW PUMPS)

~

'1 l e

tea pl